137 research outputs found

    Oxygenation by a superhydrophobic slip G/L contactor

    Get PDF
    The compelling need for an efficient supply of gases into liquids or degassing of fluids within confined microchannels triggered our study on membrane assisted microchemical systems. Porous hydrophobic flat/micro-structured polyvinylidene fluoride (PVDF) membranes were fabricated and integrated in a glass G/L contacting microfluidic device with the aid of optical adhesives. The oxygen transport in microchannels, driven by convection and diffusion, was investigated both experimentally and numerically. The effects of intrinsic membrane morphology on the G/L contacting performance of the resultant membranes were studied. The experimental performance of the flat membranes are shown to obey the simulation results with the assumptions of negligible gas phase and membrane mass transfer limitations. Micro-structured membranes revealed apparent slippage and enhanced mass transport rates, and exceeded the experimental performance of the flat membrane

    Well-defined side-chain liquid-crystalline polysiloxanes

    Get PDF
    A route to well-defined side-chain liquid-crystalline polysiloxanes (ratio of weight-to number-average molar masses Mw/Mn < 1.2 is reported. Anionic ring-opening polymerization of pentamethylvinylcyclotrisiloxane yielded a poly(dimethylsiloxane-co-methylvinylsiloxane) backbone. A flexible disiloxane spacer was used to connect 4-(ω-alkenyloxy)-4'-cyanobiphenyl mesogenic molecules to the vinyl groups which belong to the backbone, leading to a side-chain liquid-crystalline polysiloxane (SCLCP) which has its mesogens distributed regularly along the main chain. Preliminary measurements indicate an electro-optic switching time s = 1 min at 20°C and 7 s at 32°C (dc, 5 V/µm))

    Temperature effects on the electrohydrodynamic and electrokinetic behaviour of ion-selective nanochannels

    Get PDF
    A non-isothermal formulation of the Poisson–Nernst–Planck with Navier–Stokes equations is used to study the influence of heating effects in the form of Joule heating and viscous dissipation and imposed temperature gradients on a microchannel/nanochannel system. The system is solved numerically under various cases in order to determine the influence of temperature-related effects on ion-selectivity, flux and fluid flow profiles, as well as coupling between these phenomena. It is demonstrated that for a larger reservoir system, the effects of Joule heating and viscous dissipation only become relevant for higher salt concentrations and electric field strengths than are compatible with ion-selectivity due to Debye layer overlap. More interestingly, it is shown that using different temperature reservoirs can have a strong influence on ion-selectivity, as well as the induced electrohydrodynamic flows

    Influence of temperature gradients on mono- and divalent ion transport in electrodialysis at limiting currents

    Get PDF
    Temperature gradients in electrodialysis (ED) stacks can potentially enhance the efficiency of charge separation and the selective transport of ions. We have previously investigated temperature gradients in the Ohmic regime but not in the limiting current regime, where diffusion of ions towards the membrane determines the transport rate and temperature gradients potentially have the largest influence. In this research, commercial ion exchange membranes (FAS and FKS, FUMATECH, Germany) are used for the investigation of temperature gradients in the limiting current regime. In contrast to the Ohmic regime, we find that heating the diluted stream increases the current obtained (at a constant applied potential) when compared to heating the concentrate stream in systems containing monovalent KCl and NaCl solutions. For mixtures of mono- and divalent ions, the temperature gradient has a larger influence on the selectivity of the separation. If the desalinated stream is heated, divalent Mg2+ ions show a higher transport than the monovalent K+ and Na+ ions. This is due to the enhanced competitive transport of the mono- and divalent ions under the application of a temperature gradient. These results show the potential application and relevance of temperature gradients to enhance the selective separation of mono- and divalent ions

    Influence of temperature gradients on charge transport in asymmetric nanochannels

    Get PDF
    Charge selective asymmetric nanochannels are used for a variety of applications, such as nanofluidic sensing devices and energy conversion applications. In this paper, we numerically investigate the influence of an applied temperature difference over tapered nanochannels on the resulting charge transport and flow behavior. Using a temperature-dependent formulation of the coupled Poisson-Nernst-Planck and Navier-Stokes equations, various nanochannel geometries are investigated. Temperature has a large influence on the total ion transport, as the diffusivity of ions and viscosity of the solution are strongly affected by temperature. We find that the selectivity of the nanochannels is enhanced with increasing asymmetry ratios, while the total current is reduced at higher asymmetry cases. Most interestingly, we find that applying a temperature gradient along the electric field and along the asymmetry direction of the nanochannel enhances the selectivity of the tapered channels even further, while a temperature gradient countering the electric field reduces the selectivity of the nanochannel. Current rectification is enhanced in asymmetric nanochannels if a temperature gradient is applied, independent of the direction of the temperature difference. However, the degree of rectification is dependent on the direction of the temperature gradient with respect to the channel geometry and the electric field direction. The enhanced selectivity of nanochannels due to applied temperature gradients could result in more efficient operation in energy harvesting or desalination applications, motivating experimental investigations

    Flux stabilization of silicon nitride microsieves by backpulsing and surface modification with PEG moieties

    Get PDF
    The influence of the surface properties of chemically modified silicon nitride microsieves on the filtration of protein solutions and defatted milk is described in this research. Prior to membrane filtrations, an antifouling polymer based on poly(ethylene glycol), poly(TMSMA-r-PEGMA) was synthesized and applied on silicon-based surfaces like silicon, silicon nitride, and glass. The ability of such coating to repel proteins like bovine serum albumin (BSA) was confirmed by ellipsometry and confocal fluorescence microscopy. In BSA and skimmed milk filtrations no differences could be seen between unmodified and PEG-coated membranes (decreasing permeability in time). On the other hand, reduced fouling was observed with PEG-modified microsieves in combination with backpulsing and air sparging

    Enhanced ion transport using geometrically structured charge selective interfaces

    Get PDF
    A microfluidic platform containing charged hydrogels is used to investigate the effect of geometry on charge transport in electrodialysis applications. The influence of heterogeneity on ion transport is determined by electrical characterization and fluorescence microscopy of three different hydrogel geometries. We found that electroosmotic transport of ions towards the hydrogel is enhanced in heterogeneous geometries, as a result of the inhomogeneous electric field in these systems. This yields higher ionic currents for equal applied potentials when compared to homogeneous geometries. The contribution of electroosmotic transport is present in all current regimes, including the Ohmic regime. We also found that the onset of the overlimiting current occurs at lower potentials due to the increased heterogeneity in hydrogel shape, owing to the non-uniform electric field distribution in these systems. Pinning of ion depletion and enrichment zones is observed in the heterogeneous hydrogel systems, due to electroosmotic flows and electrokinetic instabilities. Our platform is highly versatile for the rapid investigation of the effects of membrane topology on general electrodialysis characteristics, including the formation of ion depletion zones on the micro-scale and the onset of the overlimiting current
    • …
    corecore