127 research outputs found
Recommended from our members
Role Of Point Of Care Ultrasound In The Diagnosis Of Retinal Detachment In The Emergency Department.
Ocular complaints represent up to 3% of all emergency department (ED) visits. These presentations can result in permanent vision loss if not promptly diagnosed and treated. Recently, point of care ultrasound (POCUS) has been investigated for the evaluation of ocular pathology in the ED. Multiple studies have investigated the role that ultrasound may play in the early diagnosis of these patients. Ocular ultrasound can be used to visualize the structures of the eye and evaluate for pathology such as retinal detachment, vitreous hemorrhage and vitreous detachment. This comprehensive review aims to present current evidence for the efficacy and reliability of ED ocular ultrasound use in the detection of retinal detachment and additional ocular pathologies
Recommended from our members
Tricuspid Annular Plane of Systolic Excursion for the Evaluation of Patients with Severe Sepsis and Septic Shock
Introduction: Sepsis is a systemic infection that can rapidly progress into multi organ failure and shock if left untreated. Previous studies have demonstrated the utility of point of care ultrasound (POCUS) in the evaluation of patients with sepsis. However, limited data exists on the evaluation of the tricuspid annular plane of systolic excursion (TAPSE) in patients with sepsis.Methods: We prospectively enrolled patients who presented to the emergency department (ED) with concern for severe sepsis or septic shock in a pilot study. In patients that screened positive, the treating physician then performed POCUS to measure the TAPSE value. We compared the intensive care unit (ICU) admission rate, hospital length of stay, and morbidity with their respective TAPSE values.Results: We enrolled 24 patients in the study. Eight patients had TAPSE values less than 16 millimeters (mm), two patients had TAPSE values between 16mm-20mm, and fourteen patients had TAPSE values greater than 20mm. There was no statistically significant association between TAPSE levels and ICU admission (p=0.16), or death (p=0.14). The difference of length of stay (LOS) was not statistically significant in case of hospital LOS (p= 0.72) or ICU LOS.Conclusion: Our pilot data did not demonstrate a correlation between severe sepsis or septic shock and TAPSE values. This may be due to several factors including patient comorbidities, strict definitions of sepsis and septic shock, as well as the absence of septic cardiomyopathy (SCM) in patients with sepsis and septic shock. Future large-scale studies are needed to determine if TAPSE can be beneficial in the ED evaluation of patients with concern for SCM
Comparison of Pressures Applied by Digital Tourniquets in the Emergency Department
Background: Digital tourniquets used in the emergency department have been scrutinized due to complications associated with their use, including neurovascular injury secondary to excessive tourniquet pressure and digital ischemia caused by a forgotten tourniquet. To minimize these risks, a conspicuous tourniquet that applies the least amount of pressure necessary to maintain hemostasis is recommended.Objective: To evaluate the commonly used tourniquet methods, the Penrose drain, rolled glove, the Tourni-cot and the T-Ring, to determine which applies the lowest pressure while consistently preventing digital perfusion.Methods: We measured the circumference of selected digits of 200 adult males and 200 adult females to determine the adult finger size range. We then measured the pressure applied to four representative finger sizes using a pressure monitor and assessed the ability of each method to prevent digital blood flow with a pulse oximeter.Results: We selected four representative finger sizes: 45mm, 65mm, 70mm, and 85mm to test the different tourniquet methods. All methods consistently prevented digital perfusion. The highest pressure recorded for the Penrose drain was 727 mmHg, the clamped rolled glove 439, the unclamped rolled glove 267, Tourni-cot 246, while the T-Ring had the lowest at 151 mmHg and least variable pressures of all methods.Conclusion: All tested methods provided adequate hemostasis. Only the Tourni-cot and T-Ring provided hemostasis at safe pressures across all digit sizes with the T-Ring having a lower overall average pressure. [West J Emerg Med. 2011;12(2):242-249.
Crash Injury Prediction and Vehicle Damage Reporting by Paramedics
Objective: The accuracy of pre-hospital crash scene details and crash victim assessment has important implications for initial trauma care assessment and management. Similarly, it is known to influence physician perception of crash victim injury severity. The goal of this feasibility study was to examine paramedic accuracy in predicting crash victim injury profile, disability outcome at hospital discharge, and reporting vehicle damage with other crash variables.Methods: This prospective case series study was undertaken at a Southern California, Level I trauma center certified by the American College of Surgeons. Paramedics transporting crash injured motor vehicle occupants to our emergency department (ED)/trauma center were surveyed. We abstracted ED and in-patient records of injured vehicle occupants. Vehicle and crash scene data were obtained from a professional crash reconstruction, which included the assessment of deformation, crash forces, change in velocity, and the source of each injury.Results: We used survey, injury, and crash reconstruction data from 22 collision cases in the final analysis. The median Injury Severity Score (ISS) was five (range 1-24). No enrolled patients died, and none were severely disabled at the time of discharge from the hospital. The paramedic crash injury severity predictions were sensitive for an Abbreviated Injury Scale (AIS) of 2-4. Paramedics often agreed with the crash reconstruction on restraint use, ejection, and other fatalities at the scene, and had lower levels of agreement for front airbag deployment, steering wheel damage, and window/windshield impact. Paramedics had 80% accuracy in predicting any disability at the time of hospital discharge.Conclusion: Paramedic prediction of injury profile was sensitive, and prediction of disability outcome at discharge was accurate when compared to discharge diagnosis. Their reporting of vehicle specific crash variables was less accurate. Further study should be undertaken to assess the benefits of crash biomechanics education for paramedics and other pre-hospital care providers. [WestJEM. 2009;10:62-67.
Recommended from our members
A Prospective Evaluation of Point of Care Ultrasound Teaching in Switzerland.
ContextAs the utility of point-of-care ultrasound (POCUS) continues to expand in the medical field, there is a need for effective educational methods. In Switzerland, medical education follows the European model and lasts 6 years, focusing on preclinical training during the first 2 years. No previous studies have evaluated the optimal time for teaching ultrasound in European medical education.AimsThe aim of this study is to provide ultrasound training to medical students in Switzerland at varying times during their clinical training to determine if the level of training plays a role in their ability to comprehend and to apply basic POCUS skills.MethodsWe performed an observational study utilizing a convenience sample of Swiss medical students between July 11, 2016 and August 6, 2016. They were taught a 2-day POCUS course by five American-trained 1st-year medical students. Following this course, students were evaluated with written and clinical examination.Results100 Swiss medical students were enrolled in the study. A total of 59 of these students were early clinical students, and 41 students were late clinical students. A two-tailed t-test was performed and demonstrated that the late clinical students performed better than the early clinical students on the written assessment; however, no difference was found in clinical skill.ConclusionOur data suggest that Swiss medical students can learn and perform POCUS after a 2-day instructional taught by trained 1st-year American medical students. No difference was found between students in early clinical training and late clinical training for the ability to perform POCUS
- …