Variability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer
BACKGROUND: Recently, instruments for the measurement of wavefront aberration in the living human eye have been widely available for clinical applications. Despite the extensive background experience on wavefront sensing for research purposes, the information derived from such instrumentation in a clinical setting should not be considered a priori precise. We report on the variability of such an instrument at two different pupil sizes. METHODS: A clinical aberrometer (COAS Wavefront Scienses, Ltd) based on the Shack-Hartmann principle was employed in this study. Fifty consecutive measurements were perfomed on each right eye of four subjects. We compared the variance of individual Zernike expansion coefficients as determined by the aberrometer with the variance of coefficients calculated using a mathematical method for scaling the expansion coefficients to reconstruct wavefront aberration for a reduced-size pupil. RESULTS: Wavefront aberration exhibits a marked variance of the order of 0.45 microns near the edge of the pupil whereas the central part appears to be measured more consistently. Dispersion of Zernike expansion coefficients was lower when calculated by the scaling method for a pupil diameter of 3 mm as compared to the one introduced when only the central 3 mm of the Shack – Hartmann image was evaluated. Signal-to-noise ratio was lower for higher order aberrations than for low order coefficients corresponding to the sphero-cylindrical error. For each subject a number of Zernike expansion coefficients was below noise level and should not be considered trustworthy. CONCLUSION: Wavefront aberration data used in clinical care should not be extracted from a single measurement, which represents only a static snapshot of a dynamically changing aberration pattern. This observation must be taken into account in order to prevent ambiguous conclusions in clinical practice and especially in refractive surgery
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism.
METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively.
RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six (81.5 %) and 78 (94.0 %) eyes were within ±0.50 D for TICL and bioptics groups, respectively. The mean Snellen UDVA was not statistically different between both procedures (p = 0.909); 53 (65.4 %) and 54 (65.1 %) eyes achieved at least 20/25 or better in TICL and bioptics groups, respectively. No eye had lost more than two lines of CDVA, and 32.1 % of eyes (26/81) in the TICL group and 57.8 % of eyes (48/83) in the bioptics group had better postoperative UDVA than preoperative CDVA (p < 0.001). Safety was not statistically different between groups (p = 0.464) while efficacy was significantly higher in the bioptics group (p = 0.000). Two eyes with a TICL were treated to correct TICL decentration.
CONCLUSIONS: Bioptics showed slightly better outcomes in some clinical measures such as uncorrected visual acuity, efficacy, and refractive predictability. TICL implantation shows reliable results similar to bioptics. A single procedure with TICL implantation might be preferred, eliminating the inherent risks of laser treatments and the risks of a second surgical procedure.The authors have no proprietary interests in any of the materials mentioned in this article. This research was supported in part by a Universitat de Valencia Research Grant to Robert Montes-Mico (#SAF2009-13342 and #SAF2008-01114-E#) and Fundacao para a Ciencia e Tecnologia of Portugal through a Grant to Paulo Fernandes (#FCT-SFRH-BD-34303-2007#)
The Morphology and Intrinsic Excitability of Developing Mouse Retinal Ganglion Cells
The retinal ganglion cells (RGCs) have diverse morphology and physiology. Although some studies show that correlations between morphological properties and physiological properties exist in cat RGCs, these properties are much less distinct and their correlations are unknown in mouse RGCs. In this study, using three-dimensional digital neuron reconstruction, we systematically analyzed twelve morphological parameters of mouse RGCs as they developed in the first four postnatal weeks. The development of these parameters fell into three different patterns and suggested that contact from bipolar cells and eye opening might play important roles in RGC morphological development. Although there has been a general impression that the morphological parameters are not independent, such as RGCs with larger dendritic fields usually have longer but sparser dendrites, there was not systematic study and statistical analysis proving it. We used Pearson's correlation coefficients to determine the relationship among these morphological parameters and demonstrated that many morphological parameters showed high statistical correlation. In the same cells we also measured seven physiological parameters using whole-cell patch-clamp recording, focusing on intrinsic excitability. We previously reported the increase in intrinsic excitability in mouse RGCs during early postnatal development. Here we showed that strong correlations also existed among many physiological parameters that measure the intrinsic excitability. However, Pearson's correlation coefficient revealed very limited correlation across morphological and physiological parameters. In addition, principle component analysis failed to separate RGCs into clusters using combined morphological and physiological parameters. Therefore, despite strong correlations within the morphological parameters and within the physiological parameters, postnatal mouse RGCs had only limited correlation between morphology and physiology. This may be due to developmental immaturity, or to selection of parameters
- …