4,395 research outputs found

    Identification of sugarcane interspecies hybrids with RAPDs

    Get PDF
    Identification of “Saccharum officinarum × Erianthus fulvus” F1 hybrids was performed with random amplified polymorphic DNA (RAPD) analysis. Of 280 RAPD primers used, two primers, OPA-19 and OPN-11, were found to be the most suitable for identification of the hybrids. And the hybrids facticitycheck-out rate was 70.6 and 68.3%, respectively

    Biomechanical study of the funnel technique applied in thoracic pedicle screw replacement

    Get PDF
    Background: Funnel technique is a method used for the insertion of screw into thoracic pedicle.Aim: To evaluate the biomechanical characteristics of thoracic pedicle screw placement using the Funnel technique, trying to provide biomechanical basis for clinical application of this technology.Methods: 14 functional spinal units (T6 to T10) were selected from thoracic spine specimens of 14 fresh adult cadavers, and randomly divided into two groups, including Funnel technique group (n=7) and Magerl technique group (n=7). The displacement-stiffness and pull-out strength in all kinds of position were tested and compared.Results: Two fixed groups were significantly higher than that of the intact state (P<0.05) in the spinal central axial direction, compression, anterior flexion, posterior bending, lateral bending, axial torsion, but there were no significant differences between two fixed groups (P>0.05). The mean pull-out strength in Funnel technique group (789.09±27.33) was lower than that in Magerl technique group (P<0.05).Conclusions: The Funnel technique for the insertion point of posterior bone is a safe and accurate technique for pedicle screw placement. It exhibited no effects on the stiffness of spinal column, but decreased the pull-out strength of pedicle screw. Therefore, the funnel technique in the thoracic spine affords an alternative for the standard screw placement.Keywords: Thoracic; Pedicle screws; Biomechanics; Funnel techniqu

    Genetic enrichment of cardiomyocytes derived from mouse embryonic stem cells

    Get PDF
    Pluripotent embryonic stem cells (ESC) have the ability to differentiate into a variety of cell lineages in vitro, including cardiomyocytes. Successful applications of ESC-derived cardiomyocytes in cell therapy and tissue engineering were limited by difficulties in selecting the desired cells from the heterogeneous cell population. We describe a simple method to generate relatively pure cardiomyocytes from mouse ESCs. A construct comprising mouse cardiac α-myosin heavy chain (MHC) promoter driving the neomycin resistance gene and SV40 promoter driving the hygromycin resistant gene designated pMHCneo/ SV40-hygro, was stably transfected into mouse ESCs. The transgenic ESC line, designated MN6 retained the undifferentiated state and the potential of cardiogenic differentiation. After G418 selection, more than 99% of cells expressed α-sarcomeric actin. Immunocytological and ultrastructural analysis demonstrated that, the selected cardiomyocytes were highly differentiated. Our results represent a simple genetic manipulation used to product essentially pure cardiomyocytes from differentiating ESCs. It may facilitate the development of cell therapy in heart diseases.Key words: Embryonic stem cells, α-myosin heavy chain promoter, cardiomyocytes, differentiation, genetic enrichment

    Prevalence and anatomical location of muscle tenderness in adults with nonspecific neck/shoulder pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Many adults experience bothersome neck/shoulder pain. While research and treatment strategies often focus on the upper trapezius, other neck/shoulder muscles may be affected as well. The aim of the present study is to evaluate the prevalence and anatomical location of muscle tenderness in adults with nonspecific neck/shoulder pain.</p> <p>Methods</p> <p>Clinical neck/shoulder examination at two large office workplaces in Copenhagen, Denmark. 174 women and 24 men (aged 25-65 years) with nonspecific neck/shoulder pain for a duration of at least 30 days during the previous year and a pain intensity of at least 2 on a modified VAS-scale of 0-10 participated. Exclusion criteria were traumatic injuries or other serious chronic disease. Using a standardized finger pressure of 2 kg, palpable tenderness were performed of eight anatomical neck/shoulder locations in the left and right side on a scale of 'no tenderness', 'some tenderness' and 'severe tenderness'.</p> <p>Results</p> <p>In women, the levator scapulae, neck extensors and infraspinatus showed the highest prevalence of severe tenderness (18-30%). In comparison, the prevalence of severe tenderness in the upper trapezius, occipital border and supraspinatus was 13-19%. Severe tenderness of the medial deltoid was least prevalent (0-1%). In men, the prevalence of severe tenderness in the levator scapulae was 13-21%, and ranged between 0-8% in the remainder of the examined anatomical locations.</p> <p>Conclusions</p> <p>A high prevalence of tenderness exists in several anatomical locations of the neck/shoulder complex among adults with nonspecific neck/shoulder pain. Future research should focus on several neck/shoulder muscles, including the levator scapulae, neck extensors and infraspinatus, and not only the upper trapezius.</p> <p>Trial Registration</p> <p><a href="http://www.controlled-trials.com/ISRCTN60264809">ISRCTN60264809</a></p

    Orientation relationships between TiB (B27), B2, and Ti₃Al phases

    Get PDF
    Version of RecordPublishe

    Precision Astrometry of a Sample of Speckle Binaries and Multiples with the Adaptive Optics Facilities at the Hale and Keck II Telescopes

    Get PDF
    Using the adaptive optics facilities at the 200-in Hale and 10-m Keck II, we observed in the near infrared a sample of 12 binary and multiple stars and one open cluster. We used the near diffraction limited images of these systems to measure the relative separations and position angles between their components. In this paper, we investigate and correct for the influence of the differential chromatic refraction and chip distortions on our relative astrometric measurements. Over one night, we achieve an astrometric precision typically well below 1 miliarcsecond and occasionally as small as 40 microarcseconds. Such a precision is in principle sufficient to astrometrically detect planetary mass objects around the components of nearby binary and multiple stars. Since we have not had sufficiently large data sets for the observed sample of stars to detect planets, we provide the limits to planetary mass objects based on the obtained astrometric precision.Comment: 18 pages, 8 figures, 9 tables, to appear in MNRA

    New Concepts of Fluorescent Probes for Specific Detection of DNA Sequences: Bis-Modified Oligonucleotides in Excimer and Exciplex Detection

    Get PDF
    The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5′-bispyrene and 3′-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5′-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5′-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing

    Double dermal sinuses: a case study

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Dermal sinus tracts are rare congenital lesions located in the midline characterized by a cutaneous pit or dimple. They occur all along the midline neuroaxis, from the nasion and occipital area down to the lumbar and sacral regions, most frequently in the lumbar and lumbosacral region.</p> <p>Case presentation</p> <p>Here we report a 5-year-old girl who presented with occasional headache. There were two dimples, one on the dorsal aspect of her head and another on her neck.</p> <p>Conclusion</p> <p>Dermal sinuses are almost always singular and the co-existence of double dermal sinuses has not been reported previously.</p
    corecore