319 research outputs found
Recommended from our members
Electronic Structure of the ID Conductor K0.3MoO3 studied using resonant inelastic x-ray scattering and soft x-ray emission spectroscopy
The electronic structure of the quasi-one dimensional conductor K{sub 0.3}MoO{sub 3} has been measured using high resolution resonant inelastic x-ray scattering and x-ray absorption spectroscopy. The data is compared to that from the related two dimensional insulator {alpha}-MoO{sub 3}. Scattering features are observed from both oxides that are explained in terms of the band momentum selectivity of the scattering process, allowing a comparison of the scattering data to recent band structure calculations
BaVS probed by V L edge X-ray absorption spectroscopy
Polarization dependent vanadium L edge X-ray absorption spectra of BaVS
single crystals are measured in the four phases of the compound. The difference
between signals with the polarization \textbf{E}\textbf{c} and
\textbf{E}\textbf{c} (linear dichroism) changes with temperature.
Besides increasing intensity of one of the maxima, a new structure appears in
the pre-edge region below the metal-insulator transition. More careful
examination brings to light that the changes start already with pretransitional
charge density wave fluctuations. Simple symmetry analysis suggests that the
effect is related to rearrangements in and states, and is
compatible with the formation of four inequivalent V sites along the V-S chain.Comment: 6 pages, 6 figure
A new short uncemented, proximally fixed anatomic femoral implant with a prominent lateral flare: design rationals and study design of an international clinical trial
<p>Abstract</p> <p>Background</p> <p>Anatomic short femoral prostheses with a prominent lateral flare have the potential to reduce stress-shielding in the femur through a more physiological stress distribution to the proximal femur. We present the design rationale of a new short uncemented, proximally fixed anatomic femoral implant and the study design of a prospective multi-centre trial to collect long-term patient outcome and radiographic follow up data.</p> <p>Methods</p> <p>A prospective surveillance study (trial registry NCT00208555) in four European centres (UK, Italy, Spain and Germany) with a follow up period of 15 years will be executed. The recruitment target is 200 subjects, patients between the ages of 18 and 70 admitted for primary cementless unilateral THA will be included. The primary objective is to evaluate the five-year survivorship of the new cementless short stem. The secondary objectives of this investigation are to evaluate the long term survivorship and the clinical performance of the implant, the impact on the subjects health related Quality of Life and the affect of the prosthesis on bone mineral density. Peri- and postoperative complications will be registered. Clinical and radiographic evaluation of prosthesis positioning will be done post-operatively and at 3, 6, 12, 24, 60, 120 and 180 months follow up.</p> <p>Discussion</p> <p>Shortening of the distal stem can maximise bone and soft tissue conservation. New stem types have been designed to improve the limitations of traditional implants in primary THA. A new, uncemented femoral short stem is introduced in this paper. A long-term follow up study has been designed to verify stable fixation and to research into the clinical outcome. The results of this trial will be presented as soon as they become available.</p
Recommendations for a core outcome set for measuring standing balance in adult populations: a consensus-based approach
Standing balance is imperative for mobility and avoiding falls. Use of an excessive number of standing balance measures has limited the synthesis of balance intervention data and hampered consistent clinical practice.To develop recommendations for a core outcome set (COS) of standing balance measures for research and practice among adults.A combination of scoping reviews, literature appraisal, anonymous voting and face-to-face meetings with fourteen invited experts from a range of disciplines with international recognition in balance measurement and falls prevention. Consensus was sought over three rounds using pre-established criteria.The scoping review identified 56 existing standing balance measures validated in adult populations with evidence of use in the past five years, and these were considered for inclusion in the COS.Fifteen measures were excluded after the first round of scoring and a further 36 after round two. Five measures were considered in round three. Two measures reached consensus for recommendation, and the expert panel recommended that at a minimum, either the Berg Balance Scale or Mini Balance Evaluation Systems Test be used when measuring standing balance in adult populations.Inclusion of two measures in the COS may increase the feasibility of potential uptake, but poses challenges for data synthesis. Adoption of the standing balance COS does not constitute a comprehensive balance assessment for any population, and users should include additional validated measures as appropriate.The absence of a gold standard for measuring standing balance has contributed to the proliferation of outcome measures. These recommendations represent an important first step towards greater standardization in the assessment and measurement of this critical skill and will inform clinical research and practice internationally
Patient-reported outcomes of femoral osteotomy and total hip arthroplasty for osteonecrosis of the femoral head: a prospective case series study
Whales from space: Four mysticete species described using new VHR satellite imagery
© 2018 The Authors. Marine Mammal Science published by Wiley Periodicals, Inc. on behalf of Society for Marine Mammalogy. Large-bodied animals such as baleen whales can now be detected with very high resolution (VHR) satellite imagery, allowing for scientific studies of whales in remote and inaccessible areas where traditional survey methods are limited or impractical. Here we present the first study of baleen whales using the WorldView-3 satellite, which has a maximum spatial resolution of 31 cm in the panchromatic band, the highest currently available to nonmilitary professionals. We manually detected, described, and counted four different mysticete species: fin whales (Balaenoptera physalus) in the Ligurian Sea, humpback whales (Megaptera novaeangliae) off Hawaii, southern right whales (Eubalaena australis) off PenÃnsula Valdés, and gray whales (Eschrichtius robustus) in Laguna San Ignacio. Visual and spectral analyses were conducted for each species, their surrounding waters, and nonwhale objects (e.g., boats). We found that behavioral and morphological differences made some species more distinguishable than others. Fin and gray whales were the easiest to discern due to their contrasting body coloration with surrounding water, and their prone body position, which is proximal to the sea surface (i.e., body parallel to the sea surface). These results demonstrate the feasibility of using VHR satellite technology for monitoring the great whales
- …