1,465 research outputs found

    Shear-strain-mediated magnetoelectric effects revealed by imaging.

    Get PDF
    Large changes in the magnetization of ferromagnetic films can be electrically driven by non-180° ferroelectric domain switching in underlying substrates, but the shear components of the strains that mediate these magnetoelectric effects have not been considered so far. Here we reveal the presence of these shear strains in a polycrystalline film of Ni on a 0.68Pb(Mg1/3Nb2/3)O3-0.32PbTiO3 substrate in the pseudo-cubic (011)pc orientation. Although vibrating sample magnetometry records giant magnetoelectric effects that are consistent with the hitherto expected 90° rotations of a global magnetic easy axis, high-resolution vector maps of magnetization (constructed from photoemission electron microscopy data, with contrast from X-ray magnetic circular dichroism) reveal that the local magnetization typically rotates through smaller angles of 62-84°. This shortfall with respect to 90° is a consequence of the shear strain associated with ferroelectric domain switching. The non-orthogonality represents both a challenge and an opportunity for the development and miniaturization of magnetoelectric devices.Isaac Newton Trust, the Royal Society, University of Wisconsin Madison, Agència de Gestió d'Ajuts Universitaris i de Recercaa - Generalitat de Cataluny

    Digital PCR methods improve detection sensitivity and measurement precision of low abundance mtDNA deletions

    Get PDF
    Mitochondrial DNA (mtDNA) mutations are a common cause of primary mitochondrial disorders, and have also been implicated in a broad collection of conditions, including aging, neurodegeneration, and cancer. Prevalent among these pathogenic variants are mtDNA deletions, which show a strong bias for the loss of sequence in the major arc between, but not including, the heavy and light strand origins of replication. Because individual mtDNA deletions can accumulate focally, occur with multiple mixed breakpoints, and in the presence of normal mtDNA sequences, methods that detect broad-spectrum mutations with enhanced sensitivity and limited costs have both research and clinical applications. In this study, we evaluated semi-quantitative and digital PCR-based methods of mtDNA deletion detection using double-stranded reference templates or biological samples. Our aim was to describe key experimental assay parameters that will enable the analysis of low levels or small differences in mtDNA deletion load during disease progression, with limited false-positive detection. We determined that the digital PCR method significantly improved mtDNA deletion detection sensitivity through absolute quantitation, improved precision and reduced assay standard error

    Linked randomised controlled trials of face-to-face and electronic brief intervention methods to prevent alcohol related harm in young people aged 14–17 years presenting to Emergency Departments (SIPS junior)

    Get PDF
    Background: Alcohol is a major global threat to public health. Although the main burden of chronic alcohol-related disease is in adults, its foundations often lie in adolescence. Alcohol consumption and related harm increase steeply from the age of 12 until 20 years. Several trials focusing upon young people have reported significant positive effects of brief interventions on a range of alcohol consumption outcomes. A recent review of reviews also suggests that electronic brief interventions (eBIs) using internet and smartphone technologies may markedly reduce alcohol consumption compared with minimal or no intervention controls. Interventions that target non-drinking youth are known to delay the onset of drinking behaviours. Web based alcohol interventions for adolescents also demonstrate significantly greater reductions in consumption and harm among ‘high-risk’ drinkers; however changes in risk status at follow-up for non-drinkers or low-risk drinkers have not been assessed in controlled trials of brief alcohol interventions

    Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.

    No full text
    Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2), and haemoglobin saturation (SaO2), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity.165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO2 x haemoglobin x 1.34/100.There was wide variation in SaO2 on air (78.5-99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO2 explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO2 but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO2 and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO2, but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up.Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content per unit blood volume. This can be maintained for SaO2 ≥78.5%, and resets to the same arterial oxygen content after correction of hypoxaemia. Serum iron concentrations, not ferritin, seem to predict more successful polycythaemic responses

    A 30-Min Nucleic Acid Amplification Point-of-Care Test for Genital Chlamydia trachomatis Infection in Women: A Prospective, Multi-center Study of Diagnostic Accuracy.

    Get PDF
    BACKGROUND: Rapid Point-Of-Care Tests for Chlamydia trachomatis (CT) may reduce onward transmission and reproductive sexual health (RSH) sequelae by reducing turnaround times between diagnosis and treatment. The io® single module system (Atlas Genetics Ltd.) runs clinical samples through a nucleic acid amplification test (NAAT)-based CT cartridge, delivering results in 30min. METHODS: Prospective diagnostic accuracy study of the io® CT-assay in four UK Genito-Urinary Medicine (GUM)/RSH clinics on additional-to-routine self-collected vulvovaginal swabs. Samples were tested "fresh" within 10days of collection, or "frozen" at -80°C for later testing. Participant characteristics were collected to assess risk factors associated with CT infection. RESULTS: CT prevalence was 7.2% (51/709) overall. Sensitivity, specificity, positive and negative predictive values of the io® CT assay were, respectively, 96.1% (95% Confidence Interval (CI): 86.5-99.5), 97.7% (95%CI: 96.3-98.7), 76.6% (95%CI: 64.3-86.2) and 99.7% (95%CI: 98.9-100). The only risk factor associated with CT infection was being a sexual contact of an individual with CT. CONCLUSIONS: The io® CT-assay is a 30-min, fully automated, high-performing NAAT currently CE-marked for CT diagnosis in women, making it a highly promising diagnostic to enable specific treatment, initiation of partner notification and appropriately intensive health promotion at the point of care

    A 30-minute nucleic acid amplification point-of-care test for genital<i>Chlamydia trachomatis</i>infection in women: a prospective, multi-centre study of diagnostic accuracy

    Get PDF
    ABSTRACTBackgroundRapid Point-Of-Care Tests (POCTs) forChlamydia trachomatis(CT) may reduce onward transmission and reproductive sexual health (RSH) sequelae by reducing turnaround times between diagnosis and treatment. The io®single module system (Atlas Genetics Ltd) runs clinical samples through a microfluidic CT cartridge, delivering results in 30 minutes. We evaluated its performance on female genital samples in four UK Genito-Urinary Medicine (GUM)/RSH clinics.MethodsProspective diagnostic accuracy study, using BD ProbeTec CT/GC assay as the routine clinic nucleic acid amplification test (NAAT) as the initial comparator test, and the QIAgen Artus CT assay to resolve discrepancies. In these instances, the reference standard was defined as the resolved result when two out of three assay results concurred. Female participants aged ≥16 provided additional-to-routine self-collected vulvovaginal swabs. Samples were tested fresh with the io®CT assay within 7 days of collection, or were frozen at −80°C for later testing. Participant clinical, demographic and behavioural characteristics were collected to assess risk factors associated with CT infection.ResultsOf 785 participants recruited, final analyses were conducted on 709 (90.3%). CT prevalence was 7.2% (51/709) overall. Sensitivity, specificity, positive and negative predictive values of the io®CT assay were, respectively, 96.1% (95% Confidence Interval (CI): 86.5-99.5), 97.7% (95%CI: 96.3-98.7), 76.6% (95%CI: 64.3-86.2) and 99.7% (95%CI: 98.9-100). There was no significant difference in performance measures between fresh and frozen samples, or between symptomatic and asymptomatic participants (p&gt;0.05). The only risk factor associated with CT infection was being a sexual contact of an individual with CT.ConclusionsThe io®CT-assay is the only 30-minute, fully automated, high-performing NAAT currently CE-marked for CT diagnosis in women, making it a highly promising diagnostic to enable specific treatment, initiation of partner notification and appropriately intensive health promotion at the point of care. Future research is required to evaluate acceptability by clinicians and patients in GUM/RSH clinics, impact on clinical pathways and patient management, and cost-effectiveness.</jats:sec

    Rhesus TRIM5α disrupts the HIV-1 capsid at the inter-hexamer interfaces

    Get PDF
    TRIM proteins play important roles in the innate immune defense against retroviral infection, including human immunodeficiency virus type-1 (HIV-1). Rhesus macaque TRIM5α (TRIM5αrh) targets the HIV-1 capsid and blocks infection at an early post-entry stage, prior to reverse transcription. Studies have shown that binding of TRIM5α to the assembled capsid is essential for restriction and requires the coiled-coil and B30.2/SPRY domains, but the molecular mechanism of restriction is not fully understood. In this study, we investigated, by cryoEM combined with mutagenesis and chemical cross-linking, the direct interactions between HIV-1 capsid protein (CA) assemblies and purified TRIM5αrh containing coiled-coil and SPRY domains (CC-SPRYrh). Concentration-dependent binding of CC-SPRYrh to CA assemblies was observed, while under equivalent conditions the human protein did not bind. Importantly, CC-SPRYrh, but not its human counterpart, disrupted CA tubes in a non-random fashion, releasing fragments of protofilaments consisting of CA hexamers without dissociation into monomers. Furthermore, such structural destruction was prevented by inter-hexamer crosslinking using P207C/T216C mutant CA with disulfide bonds at the CTD-CTD trimer interface of capsid assemblies, but not by intra-hexamer crosslinking via A14C/E45C at the NTD-NTD interface. The same disruption effect by TRIM5αrh on the inter-hexamer interfaces also occurred with purified intact HIV-1 cores. These results provide insights concerning how TRIM5α disrupts the virion core and demonstrate that structural damage of the viral capsid by TRIM5α is likely one of the important components of the mechanism of TRIM5α-mediated HIV-1 restriction. © 2011 Zhao et al

    Summarizing activity limitations in children with chronic illnesses living in the community: a measurement study of scales using supplemented interRAI items

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To test the validity and reliability of scales intended to measure activity limitations faced by children with chronic illnesses living in the community. The scales were based on information provided by caregivers to service program personnel almost exclusively trained as social workers. The items used to measure activity limitations were interRAI items supplemented so that they were more applicable to activity limitations in children with chronic illnesses. In addition, these analyses may shed light on the possibility of gathering functional information that can span the life course as well as spanning different care settings.</p> <p>Methods</p> <p>Analyses included testing the internal consistency, predictive, concurrent, discriminant and construct validity of two activity limitation scales. The scales were developed using assessment data gathered in the United States of America (USA) from over 2,700 assessments of children aged 4 to 20 receiving Medicaid Early and Periodic Screening, Diagnostic and Treatment (EPSDT) services, specifically Personal Care Services to assist children in overcoming activity limitations. The Medicaid program in the USA pays for health care services provided to children in low-income households. Data were collected in a single, large state in the southwestern USA in late 2008 and early 2009. A similar sample of children was assessed in 2010, and the analyses were replicated using this sample.</p> <p>Results</p> <p>The two scales exhibited excellent internal consistency. Evidence on the concurrent, predictive, discriminant, and construct validity of the proposed scales was strong. Quite importantly, scale scores were not correlated with (confounded with) a child's developmental stage or age. The results for these scales and items were consistent across the two independent samples.</p> <p>Conclusions</p> <p>Unpaid caregivers, usually parents, can provide assessors lacking either medical or nursing training with reliable and valid information on the activity limitations of children. One can summarize these data in scales that are both internally consistent and valid. Researchers and clinicians can use supplemented interRAI items to provide guidance for professionals and programs serving children, as well as older persons. This research emphasizes the importance of developing medical information systems that allow one to integrate information not only across care settings but also across an individual's life course.</p
    • …
    corecore