50 research outputs found

    Actinomadura meyerae osteitis following wound contamination with hay in a woman in France: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Mycetoma is a chronic granulomatous infection caused by environmental fungi or bacteria. It affects dermal and subcutaneous tissues, with putative contiguous extension to muscles or bones. While common in tropical and subtropical areas, mycetoma is rare in Europe.</p> <p>Case presentation</p> <p>We describe a case of <it>Actinomadura meyerae </it>osteitis in a 49-year-old Caucasian woman who suffered a tibia open fracture contaminated with hay; to the best of our knowledge the first case of autochthonous <it>A. meyerae </it>infection reported in France. The bacterium was cultivated from a bone biopsy. Following surgical osteosynthesis and six months of treatment with cotrimoxazole, our patient made a full recovery.</p> <p>Conclusion</p> <p>Our case report suggests that <it>A. meyerae </it>is a potential agent of wound infection in farm workers in contact with hay.</p

    Fast heating and cooling for high temperature chemical microreactors

    No full text
    Many chem. reactions, like the dehydrogenation of gaseous methanol to formaldehyde, require fast heating and cooling of the gases to control precisely the residence time at the reaction temp. (on the order of hundreds of ms) to minimize consecutive reactions. For these applications, microsystems are of great interest thanks to their characteristic high surface- to-vol. ratio and low thermal inertia. Heater and cooler units were developed with compatible micromachining technologies in view of a future integration in a complete microreactor system. The heater is composed of a silicon duct, capped with a silicon nitride membrane heated by a platinum filament. Within the mean residence time of approx. 4 ms nitrogen was heated to a max. temp. of 600 Deg. Numerical simulations are in agreement with the performed temp. measurements. However, the large temp. gradient of this prototype due to single-sided heating is not well suited for chem. reactions. A soln. with two heated membranes face-to-face is being investigated. The cooler is a co- or counter-current flow heat exchanger machined into silicon by deep plasma etching. The measured overall heat transfer coeffs. are lower than expected. This can be explained by the longitudinal heat conduction in the fins, which is neglected in the basic theory. New exchangers with thinner fins are therefore being developed but the cooling needed for our particular application (from 700 Deg to 200 Deg in a few ms) is already possible with the current structures. [on SciFinder (R)
    corecore