11,129 research outputs found

    Neutrino Spin Flavor Precession and Leptogenesis

    Full text link
    We argue that \Delta L=2 neutrino spin flavor precession, induced by the primordial magnetic fields, could have a significant impact on the leptogenesis process that accounts for the baryon asymmetry of the universe. Although the extra galactic magnetic fields is extremely weak at present time (about 10^{-9} Gauss), the primordial magnetic filed at the electroweak scale could be quite strong (of order 10^{17} Gauss). Therefore, at this scale, the effects of the spin flavor precession are not negligible. We show that the lepton asymmetry may be reduced by 50% due to the spin flavor precession. In addition, the leptogenesis will have different feature from the standard scenario of leptogenesis, where the lepton asymmetry continues to oscillate even after the electroweak phase transition.Comment: 5 pages, one figure. References adde

    Original approach for thrombolytic therapy in patients with Ilio-femoral deep vein thrombosis: 2 years follow-up

    Get PDF
    Objective: The aim of the study was to discuss the results of catheter-directed thrombolysis and complementary procedures to treat acute iliofemoral deep vein thrombosis (DVT) evaluating the safety and effectivness of an easy access such as the Great Saphenous Vein. Methods and materials: A total of 22 consecutive patients with iliofemoral thrombosis and two patients with femoro-popliteal thrombosis on recent onset diagnosed with Ultrasound Doppler and contrast venography underwent intrathrombus drip infusion of urokinase while intravenous heparin was continued using saphenical access. Residual venous stenosis were treated in six patients by percutaneous balloon Angioplasty and stenting. All patients underwent routine venous duplex imaging at 30 days, 3 months, 6 months and every 6 months thereafter. Results: Complete patency of thrombosed veins was restored in 22 patients (91 %) with prompt symptomatic relief. There were no major complications in the immediate outcomes. At follow-up, two patients reported a persistant slim iliac vein stenosis, two patients had post-thrombotic syndrome, and two patients showed Deep Vein Reflux. Conclusion: Local thrombolysis using saphenical access was a safe and effective approach for the treatment of acute iliofemoral deep vein thrombosis. It seems to be a valid, easy and safe alternative, reducing the risks of haematoma and venous lesions, which can be observed when using femoral, popliteal, and trans-jugular access

    Automated Detection of Coronal Loops using a Wavelet Transform Modulus Maxima Method

    Full text link
    We propose and test a wavelet transform modulus maxima method for the au- tomated detection and extraction of coronal loops in extreme ultraviolet images of the solar corona. This method decomposes an image into a number of size scales and tracks enhanced power along each ridge corresponding to a coronal loop at each scale. We compare the results across scales and suggest the optimum set of parameters to maximise completeness while minimising detection of noise. For a test coronal image, we compare the global statistics (e.g., number of loops at each length) to previous automated coronal-loop detection algorithms

    Human Arm simulation for interactive constrained environment design

    Get PDF
    During the conceptual and prototype design stage of an industrial product, it is crucial to take assembly/disassembly and maintenance operations in advance. A well-designed system should enable relatively easy access of operating manipulators in the constrained environment and reduce musculoskeletal disorder risks for those manual handling operations. Trajectory planning comes up as an important issue for those assembly and maintenance operations under a constrained environment, since it determines the accessibility and the other ergonomics issues, such as muscle effort and its related fatigue. In this paper, a customer-oriented interactive approach is proposed to partially solve ergonomic related issues encountered during the design stage under a constrained system for the operator's convenience. Based on a single objective optimization method, trajectory planning for different operators could be generated automatically. Meanwhile, a motion capture based method assists the operator to guide the trajectory planning interactively when either a local minimum is encountered within the single objective optimization or the operator prefers guiding the virtual human manually. Besides that, a physical engine is integrated into this approach to provide physically realistic simulation in real time manner, so that collision free path and related dynamic information could be computed to determine further muscle fatigue and accessibility of a product designComment: International Journal on Interactive Design and Manufacturing (IJIDeM) (2012) 1-12. arXiv admin note: substantial text overlap with arXiv:1012.432

    Muon Anomalous Magnetic Moment and mu -> e gamma in B-L Model with Inverse Seesaw

    Full text link
    We study the anomalous magnetic moment of the muon, a_\mu, and lepton flavor violating decay \mu -> e \gamma in TeV scale B-L extension of the Standard Model (SM) with inverse seesaw mechanism. We show that the B-L contributions to a_\mu are severely constrained, therefore the SM contribution remains intact. We also emphasize that the current experimental limit of BR(\mu -> e \gamma) can be satisfied for a wide range of parameter space and it can be within the reach of MEG experiment.Comment: 10 pages, 4 Figure

    Constraining supersymmetric models from B_d - B-bar_d mixing and the B_d --> J/psi K_S asymmetry

    Full text link
    We analyze the chargino contributions to B_d - B-bar_d mixing and CP asymmetry of the B_d --> J/psi K_S decay, in the framework of the mass insertion approximation. We derive model independent bounds on the relevant mass insertions. Moreover, we study these contributions in supersymmetric models with minimal flavor violation, Hermitian flavor structure, and small CP violating phases and universal strength Yukawa couplings. We show that in supersymmetric models with large flavor mixing, the observed values of sin(2 beta) may be entirely due to the chargino-up-squark loops.Comment: 22 pages, 1 figure, minor corrections, version to appear in Phys. Rev.

    Molecular SPECT Imaging: An Overview

    Get PDF
    Molecular imaging has witnessed a tremendous change over the last decade. Growing interest and emphasis are placed on this specialized technology represented by developing new scanners, pharmaceutical drugs, diagnostic agents, new therapeutic regimens, and ultimately, significant improvement of patient health care. Single photon emission computed tomography (SPECT) and positron emission tomography (PET) have their signature on paving the way to molecular diagnostics and personalized medicine. The former will be the topic of the current paper where the authors address the current position of the molecular SPECT imaging among other imaging techniques, describing strengths and weaknesses, differences between SPECT and PET, and focusing on different SPECT designs and detection systems. Radiopharmaceutical compounds of clinical as well-preclinical interest have also been reviewed. Moreover, the last section covers several application, of μSPECT imaging in many areas of disease detection and diagnosis

    Zero Field precession and hysteretic threshold currents in spin torque oscillators with tilted polarizer

    Full text link
    Using non-linear system theory and numerical simulations we map out the static and dynamic phase diagram in zero applied field of a spin torque oscillator with a tilted polarizer (TP-STO).We find that for sufficiently large currents, even very small tilt angles (beta>1 degree) will lead to steady free layer precession in zero field. Within a rather large range of tilt angles, 1 degree< beta <19 degree, we find coexisting static states and hysteretic switching between these using only current. In a more narrow window (1 degree<beta<5 degree) one of the static states turns into a limit cycle (precession). The coexistence of static and dynamic states in zero magnetic field is unique to the tilted polarizer and leads to large hysteresis in the upper and lower threshold currents for TP-STO operation.Comment: 5 pages, 4 figure

    Low energy consequences from supersymmetric models with left-right symmetry

    Get PDF
    We consider several low energy consequences arising from a class of supersymmetric models based on the gauge groups SU(2)L×SU(2)R×U(1)BLSU(2)_L\times SU(2)_R \times U(1)_{B-L} and SU(4)C×SU(2)L×SU(2)RSU(4)_C\times SU(2)_L \times SU(2)_R in which the gauge hierarchy and μ\mu problems have been resolved. There are important constraints on the MSSM parameters tanβ(mt/mb)\tan \beta (\simeq m_t/m_b), BB and μ\mu, and we discuss how they are reconciled with radiative electroweak breaking. We also consider the ensuing sparticle and Higgs spectroscopy, as well as the decays bsγb\to s \gamma and μeγ\mu \to e \gamma. The latter process may be amenable to experimental tests through an order of magnitude increase in sensitivity.Comment: 17 pages, latex2

    Incidental findings detected on preoperative CT imaging obtained for robotic-assisted joint replacements: clinical importance and the effect on the scheduled arthroplasty

    Get PDF
    OBJECTIVE: To determine the type and frequency of incidental findings detected on preoperative computed tomography (CT) imaging obtained for robotic-assisted joint replacements and their effect on the planned arthroplasty. MATERIALS AND METHODS: All preoperative CT examinations performed for a robotic-assisted knee or total hip arthroplasty were obtained. This resulted in 1432 examinations performed between September 2016 and February 2020 at our institution. These examinations were initially interpreted by 1 of 9 fellowship-trained musculoskeletal radiologists. Using a diagnosis search, the examination reports were then reviewed to catalog all incidental findings and further classify as significant or non-significant findings. Demographic information was obtained. In those with significant findings, a chart review was performed to record the relevant workup, outcomes, and if the planned arthroplasty was affected. RESULTS: Incidental findings were diagnosed in 740 (51.7%) patients. Of those with incidental findings, 41 (5.5%) were considered significant. A significant finding was more likely to be detected in males (P = 0.007) and on the hip protocol CT (P = 0.014). In 8 patients, these diagnoses resulted in either delay or cancelation of the arthroplasty. A planned total hip arthroplasty was more likely to be altered as compared to a knee arthroplasty (P = 0.018). CONCLUSION: Incidental findings are commonly detected by radiologists on preoperative CT imaging obtained for robotic-assisted joint replacement. Several were valuable findings and resulted in a delay or even cancelation of the planned arthroplasty after the detection of critical diagnoses, which if not identified may have resulted in devastating outcomes
    corecore