3,389 research outputs found
The extended structure of the remote cluster B514 in M31. Detection of extra-tidal stars
We present a study of the density profile of the remote M31 globular cluster
B514, obtained from HST/ACS observations. Coupling the analysis of the
distribution of the integrated light with star counts we can reliably follow
the profile of the cluster out to r~35", corresponding to ~130pc. The profile
is well fitted, out to ~15 core radii, by a King Model having C=1.65. With an
estimated core radius r_c=0.38", this corresponds to a tidal radius of r_t~17"
(~65pc). We find that both the light and the star counts profiles show a
departure from the best fit King model for r>~8" - as a surface brightness
excess at large radii, and the star counts profile shows a clear break in
correspondence of the estimated tidal radius. Both features are interpreted as
the signature of the presence of extratidal stars around the cluster. We also
show that B514 has a half-light radius significantly larger than ordinary
globular clusters of the same luminosity. In the M_V vs. log r_h plane, B514
lies in a region inhabited by peculiar clusters, like Omega Cen, G1, NGC2419
and others, as well as by the nuclei of dwarf elliptical galaxies.Comment: 9 pages, 6 figures. Accepted for publication in Astronomy &
Astrophysic
Massive young clusters in the disc of M31
We have studied the properties of a sample of 67 very blue and likely young
massive clusters in M31 extracted from the Bologna Revised Catalog of globular
clusters, selected according to their color [(B-V) < 0.45] and/or to the
strength of their Hbeta spectral index (Hbeta > 3.5 A). Their existence in M31
has been noted by several authors in the past; we show here that these Blue
Luminous Compact Clusters (BLCCs) are a significant fraction (>~ 15%) of the
whole globular cluster system of M31. Compared to the global properties of the
M31 globular cluster system, they appear to be intrinsically fainter,
morphologically less concentrated, and with a shallower Balmer jump and
enhanced absorption in their spectra.
Empirical comparison with integrated properties of clusters with known age as
well as with theoretical SSP models consistently indicate that their typical
age is less than ~2 Gyr, while they probably are not so metal-poor as deduced
if considered to be old. Either selecting BLCCs by their (B-V) colors or by the
strength of their Hbeta index the cluster sample turns out to be distributed
onto the outskirts of M31 disc, sharing the kinematical properties of the thin,
rapidly rotating disc component.
If confirmed to be young and not metal-poor, these clusters indicate the
occurrence of a significant recent star formation in the thin disc of M31,
although they do not set constraints on the epoch of its early formation.Comment: Submitted for publication in the Astronomical Journal. Aastex Latex
file of 22 pages, 12 figures and 3 table
A COMPUTER CLUSTER SYSTEM FOR PSEUDO-PARALLEL EXECUTION OF GEANT4 SERIAL APPLICATION
Simulation of the interactions between particles and matter in studies for developing X-rays detectors generally requires very long calculation times (up to several days or weeks). These times are often a serious limitation for the success of the simulations and for the accuracy of the simulated models. One of the tools used by the scientific community to perform these simulations is Geant4 (Geometry And Tracking) [2, 3]. On the best of experience in the design of the AVES cluster computing system, Federici et al. [1], the IAPS (Istituto di Astrofisica e Planetologia Spaziali INAF) laboratories were able to develop a cluster computer system dedicated to Geant 4. The Cluster is easy to use and easily expandable, and thanks to the design criteria adopted it achieves an excellent compromise between performance and cost. The management software developed for the Cluster splits the single instance of simulation on the cores available, allowing the use of software written for serial computation to reach a computing speed similar to that obtainable from a native parallel software. The simulations carried out on the Cluster showed an increase in execution time by a factor of 20 to 60 compared to the times obtained with the use of a single PC of medium quality
Non Relational Models for the Management of Large Amount of Astronomical Data
The objective of this paper is the comparison between two different database typologies: the relational and the nonrelational architecture, in the context of the applications related to the use and distribution of astronomical data. The specific context is focused to problems quite different from those related to administrative and managerial environments within which were developed the leading technologies on which are based the modern systems of massive storage of data. The data provided by astronomical instrumentation are usually filtered out by the front-end system (trigger, anticoincidence, DSP etc.), so they do not require special controls of congruence. Moreover, the related storage systems must be able to ensure an easy growth, minimizing human systemistic interventions and automating the related actions. The use of a non-relational architecture (NoSQL), offers great advantages during the insertion of informations within a data base, while the response speed of the queries is mainly tied to their type and complexity
Wide-Field Survey of Globular Clusters in M31. II. Kinematics of the Globular Cluster System
We present a kinematic analysis of the globular cluster(GC) system in M31.
Using the photometric and spectroscopic database of 504 GCs, we have
investigated the kinematics of the M31 GC system. We find that the all GC
system shows strong rotation, with rotation amplitude of v_rot~190km/s, and
that a weak rotation persists even for the outermost samples at |Y|>5kpc. The
rotation-corrected velocity dispersion for the GC system is estimated to be
sigma_{p,r}~130km/s, and it increases from sigma_{p,r}~120km/s at |Y|<1kpc to
sigma_{p,r}~150km/s at |Y|>5kpc. These results are very similar to those for
the metal-poor GCs. This shows that there is a dynamically hot halo in M31 that
is rotating but primarily pressure-supported. We have identified 50
"friendless" GCs, and they appear to rotate around the major axis of M31. For
the subsamples of metal-poor and metal-rich GCs, we have found that the
metal-rich GCs are more centrally concentrated than the metal-poor GCs, and
both subsamples show strong rotation. For the subsamples of bright and faint
GCs, it is found that the rotation for the faint GCs is stronger than that for
the bright GCs. We have identified 56 GCs and GC candidates with X-ray
detection. It is found that the majority of X-ray emitting GCs follow the disk
rotation, and that the redder, more metal-rich, and brighter GCs are more
likely to be detected as X-ray emitting GCs. We have derived a rotation curve
of M31 using the GCs at |Y|<0.6kpc. We have estimated the dynamical mass of M31
using `Projected Mass Estimator(PME)' and `Tracer Mass Estimator(TME)'. We
finally discuss the implication of these results and compare the kinematics of
GCs with that of planetary nebulae in M31.Comment: 62 pages, 26 figues, Accepted by Ap
Disinvestment in healthcare: An overview of HTA agencies and organizations activities at European level
Background: In an era of a growing economic pressure for all health systems, the interest for "disinvestment" in healthcare increased. In this context, evidence based approaches such as Health Technology Assessment (HTA) are needed both to invest and to disinvest in health technologies. In order to investigate the extent of application of HTA in this field, methodological projects/frameworks, case studies, dissemination initiatives on disinvestment released by HTA agencies and organizations located in Europe were searched. Methods: In July 2015, the websites of HTA agencies and organizations belonging to the European network for HTA (EUnetHTA) and the International Network of Agencies for HTA (INAHTA) were accessed and searched through the use of the term "disinvestment". Retrieved deliverables were considered eligible if they reported methodological projects/frameworks, case studies and dissemination initiatives focused on disinvestment in healthcare. Results: 62 HTA agencies/organizations were accessed and eight methodological projects/frameworks, one case study and one dissemination initiative were found starting from 2007. With respect to methodological projects/frameworks, two were delivered in Austria, one in Italy, two in Spain and three in U.K. As for the case study and the dissemination initiative, both came from U.K. The majority of deliverables were aimed at making an overview of existing disinvestment approaches and at identifying challenges in their introduction. Conclusions: Today, in a healthcare context characterized by resource scarcity and increasing service demand, "disinvestment" from low-value services and reinvestment in high-value ones is a key strategy that may be supported by HTA. The lack of evaluation of technologies in use, in particular at the end of their lifecycle, may be due to the scant availability of frameworks and guidelines for identification and assessment of obsolete technologies that was shown by our work. Although several projects were carried out in different countries, most remain constrained to the field of research. Disinvestment is a relatively new concept in HTA that could pose challenges also from a methodological point of view. To tackle these challenges, it is necessary to construct experiences at international level with the aim to develop new methodological approaches to produce and grow evidence on disinvestment policies and practices
Brachial Artery Constriction during Brachial Artery Reactivity Testing Predicts Major Adverse Clinical Outcomes in Women with Suspected Myocardial Ischemia: Results from the NHLBI-Sponsored Women's Ischemia Syndrome Evaluation (WISE) Study
Background:Limited brachial artery (BA) flow-mediated dilation during brachial artery reactivity testing (BART) has been linked to increased cardiovascular risk. We report on the phenomenon of BA constriction (BAC) following hyperemia.Objectives:To determine whether BAC predicts adverse CV outcomes and/or mortality in the women's ischemic Syndrome Evaluation Study (WISE). Further, as a secondary objective we sought to determine the risk factors associated with BAC.Methods:We performed BART on 377 women with chest pain referred for coronary angiography and followed for a median of 9.5 years. Forearm ischemia was induced with 4 minutes occlusion by a cuff placed distal to the BA and inflated to 40mm Hg > systolic pressure. BAC was defined as >4.8% artery constriction following release of the cuff. The main outcome was major adverse events (MACE) including all-cause mortality, non-fatal MI, non-fatal stroke, or hospitalization for heart failure.Results:BA diameter change ranged from -20.6% to +44.9%, and 41 (11%) women experienced BAC. Obstructive CAD and traditional CAD risk factors were not predictive of BAC. Overall, 39% of women with BAC experienced MACE vs. 22% without BAC (p=0.004). In multivariate Cox proportional hazards regression, BAC was a significant independent predictor of MACE (p=0.018) when adjusting for obstructive CAD and traditional risk factors.Conclusions:BAC predicts almost double the risk for major adverse events compared to patients without BAC. This risk was not accounted for by CAD or traditional risk factors. The novel risk marker of BAC requires further investigation in women. © 2013 Sedlak et al
- …