23 research outputs found

    Comparison of Radiation Doses and Best-Practice Use for Myocardial Perfusion Imaging in US and Non-US Laboratories: Findings From the IAEA (International Atomic Energy Agency) Nuclear Cardiology Protocols Study

    Get PDF
    not availabl

    Estimating the Reduction in the Radiation Burden From Nuclear Cardiology Through Use of Stress-Only Imaging in the United States and Worldwide

    Get PDF
    Not availabl

    Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries

    Get PDF
    Purpose: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. Methods: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 – 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Results: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. Conclusion: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice

    Current worldwide nuclear cardiology practices andradiationexposure: results from the 65 country IAEA nuclear cardiology protocols cross-sectional study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiationoptimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposurewere identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally

    Inter-reader variability of SPECT MPI readings in low- and middle-income countries: Results from the IAEA-MPI Audit Project (I-MAP)

    No full text
    Background: Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. Methods: The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. Results: Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. Conclusions: In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries

    Inter-reader variability of SPECT MPI readings in low- and middle-income countries: Results from the IAEA-MPI Audit Project (I-MAP)

    No full text
    Background: Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. Methods: The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. Results: Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. Conclusions: In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries

    Nuclear Cardiology Practices and Radiation Exposure in the Oceania Region: Results From the IAEA Nuclear Cardiology Protocols Study (INCAPS)

    No full text
    Background There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. Methods Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified “best practices” was determined. Results In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). Conclusion Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world

    Nuclear cardiology practice in Asia: Analysis of radiation exposure and best practice for myocardial perfusion imaging ― results from the IAEA nuclear cardiology protocols cross-sectional study (INCAPS) ―

    No full text
    Background: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia. Methods and Results: Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. Conclusions: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care

    Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols

    No full text
    Objectives: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). Background: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. Methods: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. Results: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. Conclusions: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions

    Gender Differences in Radiation Dose from Nuclear Cardiology Studies Across the World Findings from the INCAPS Registry

    Get PDF
    Objectives The aim of this study was to investigate gender-based differences in nuclear cardiology practice globally, with a particular focus on laboratory volume, radiation dose, protocols, and best practices. Background It is unclear whether gender-based differences exist in radiation exposure for nuclear cardiology procedures. Methods In a large, multicenter, observational, cross-sectional study encompassing 7,911 patients in 65 countries, radiation effective dose was estimated for each examination. Patient-level best practices relating to radiation exposure were compared between genders. Analysis of covariance was used to determine any difference in radiation exposure according to gender, region, and the interaction between gender and region. Linear, logistic, and hierarchical regression models were developed to evaluate gender-based differences in radiation exposure and laboratory adherence to best practices. The study also included the United Nations Gender Inequality Index and Human Development Index as covariates in multivariable models. Results The proportion of myocardial perfusion imaging studies performed in women varied among countries; however, there was no significant correlation with the Gender Inequality Index. Globally, mean effective dose for nuclear cardiology procedures was only slightly lower in women (9.6 ± 4.5 mSv) than in men (10.3 ± 4.5 mSv; p < 0.001), with a difference of only 0.3 mSv in a multivariable model adjusting for patients' age and weight. Stress-only imaging was performed more frequently in women (12.5% vs. 8.4%; p < 0.001); however, camera-based dose reduction strategies were used less frequently in women (58.6% vs. 65.5%; p < 0.001). Conclusions Despite significant worldwide variation in best practice use and radiation doses from nuclear cardiology procedures, only small differences were observed between genders worldwide. Regional variations noted in myocardial perfusion imaging use and radiation dose offer potential opportunities to address gender-related differences in delivery of nuclear cardiology care