114 research outputs found

    Coherent radar ice thickness measurements over the Greenland ice sheet

    Get PDF
    This is the published version, also available here: http://dx.doi.org/10.1029/2001JD900183.We developed two 150-MHz coherent radar depth sounders for ice thickness measurements over the Greenland ice sheet. We developed one of these using connectorized components and the other using radio frequency integrated circuits (RFICs). Both systems are designed to use pulse compression techniques and coherent integration to obtain the high sensitivity required to measure the thickness of more than 4 km of cold ice. We used these systems to collect radar data over the interior and margins of the ice sheet and several outlet glaciers. We operated both radar systems on the NASA P-3B aircraft equipped with GPS receivers. Radar data are tagged with GPS-derived location information and are collected in conjunction with laser altimeter measurements. We have reduced all data collected since 1993 and derived ice thickness along all flight lines flown in support of Program for Regional Climate Assessment (PARCA) investigations and the North Greenland Ice Core Project. Radar echograms and derived ice thickness data are placed on a server at the University of Kansas (http://tornado.rsl.ukans.edu/Greenlanddata.htm) for easy access by the scientific community. We obtained good ice thickness information with an accuracy of ±10 m over 90% of the flight lines flown as a part of the PARCA initiative. In this paper we provide a brief description of the system along with samples of data over the interior, along the 2000-m contour line in the south and from a few selected outlet glaciers

    Targeting the ectopy-triggering ganglionated plexuses without pulmonary vein isolation prevents atrial fibrillation

    Get PDF
    Background Ganglionated plexuses (GPs) are implicated in atrial fibrillation (AF). Endocardial high-frequency stimulation (HFS) delivered within the local atrial refractory period can trigger ectopy and AF from specific GP sites (ET-GP). The aim of this study was to understand the role of ET-GP ablation in the treatment of AF. Methods Patients with paroxysmal AF indicated for ablation were recruited. HFS mapping was performed globally around the left atrium to identify ET-GP. ET-GP was defined as atrial ectopy or atrial arrhythmia triggered by HFS. All ET-GP were ablated, and PVs were left electrically connected. Outcomes were compared with a control group receiving pulmonary vein isolation (PVI). Patients were followed-up for 12 months with multiple 48-h Holter ECGs. Primary endpoint was ≥30 s AF/atrial tachycardia in ECGs. Results In total, 67 patients were recruited and randomized to ET-GP ablation (n = 39) or PVI (n = 28). In the ET-GP ablation group, 103 ± 28 HFS sites were tested per patient, identifying 21 ± 10 (20%) GPs. ET-GP ablation used 23.3 ± 4.1 kWs total radiofrequency (RF) energy per patient, compared with 55.7 ± 22.7 kWs in PVI (p = <.0001). Duration of procedure was 3.7 ± 1.0 and 3.3 ± 0.7 h in ET-GP ablation group and PVI, respectively (p = .07). Follow-up at 12 months showed that 61% and 49% were free from ≥30 s of AF/AT with PVI and ET-GP ablation respectively (log-rank p = .27). Conclusions It is feasible to perform detailed global functional mapping with HFS and ablate ET-GP to prevent AF. This provides direct evidence that ET-GPs are part of the AF mechanism. The lower RF requirement implies that ET-GP targets the AF pathway more specifically

    A prognostic index predicting survival in transformed Waldenström macroglobulinemia

    Get PDF
    Histological transformation into diffuse large B-cell lymphoma is a rare complication in patients with Waldenström macroglobulinemia (WM) usually associated with a poor prognosis. The objective of this study was to develop and validate a prognostic index for survival in transformed WM patients. Through this multicenter, international collaborative effort, we developed a scoring system based on data from 133 patients with transformed WM who were evaluated between 1995 and 2016 (training cohort). Univariate and multivariate analyses were used to propose a prognostic index with 2-year survival after transformation as an end-point. For external validation, a data set of 67 patients was used to evaluate the performance of the model (validation cohort). By multivariate analysis, three adverse covariates were identified as independent predictors of 2-year survival after transformation: elevated serum LDH (2 points), platelet count < 100 x 109/L (1 point) and any previous treatment for WM (1 point). Three risk groups were defined: low-risk (0-1 point, 24% of patients), intermediate-risk (2-3 points, 59%, hazard ratio (HR) = 3.4) and high-risk (4 points, 17%, HR = 7.5). Two-year survival rates were 81%, 47%, and 21%, respectively (P < 0.0001). This model appeared to be a better discriminant than the International Prognostic Index (IPI) and the revised IPI (R-IPI). We validated this model in an independent cohort. This easy-to-compute scoring index is a robust tool that may allow identification of groups of transformed WM patients with different outcomes and could be used for improving the development of risk-adapted treatment strategies

    Premature ventricular contractions originating from the left ventricular septum: Results of Radiofrequency Catheter Ablation in twenty patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>RFCA has been established as an effective and curative therapy for severely symptomatic PVC from the outflow tract in structurally normal hearts. However, it is unknown whether PVCs originating from the left ventricular septum, are effectively eliminated by RFCA. This study aimed to investigate electrophysiologic characteristics and effects of Radiofrequency catheter ablation (RFCA) for patients with symptomatic premature ventricular contraction (PVC) originating from the left ventricular septum without including fascicular PVCs.</p> <p>Methods</p> <p>Characteristics of body surface electrocardiogram (ECG) and electrophysiologic recordings endocardiogram in a successful RFCA target were analyzed in 20 patients with symptomatic PVCs originating from the left ventricular septum. RFCA was performed using pace mapping and activation mapping.</p> <p>Results</p> <p>The QRS morphology of PVCs originating from the left ventricular septum is similar to that seen in fascicular tachycardia. Most of the PVCs originated from the left septum appears in the form of ventricular parasystole. The incidence of ventricular parasystole was 70%. Sustained ventricular tachycardia was not inducible by electrical stimulation and isoproterenol infusion in all 20 patients, ablation at the site recording the earliest Purkinje potential was not effective in all 20 patients, and Purkinje potentials were not identified at successful sites during point mapping. Sixteen patients were successful with RFCA using pace mapping and activation mapping, 3 failed, and 1 recurrent.</p> <p>Conclusion</p> <p>Although the ECG characteristics of the PVCs arising from the left ventricular septum are similar to that seen in fascicular tachycardia, the electrophysiologic characteristics are different between the two types of PVCs. The distinguishing characteristic of the PVCs is that Purkinje potentials were not present at the site of successful ablation, suggesting a myocardial as opposed to fascicular substrate. RFCA is an effective curative therapy for symptomatic PVCs originating from the left ventricular septum (not from the left anterior and posterior fascicle).</p

    How achievable are COVID-19 clinical trial recruitment targets? A UK observational cohort study and trials registry analysis

    Get PDF
    OBJECTIVES: To analyse enrolment to interventional trials during the first wave of the COVID-19 pandemic in England and describe the barriers to successful recruitment in the circumstance of a further wave or future pandemics. DESIGN: We analysed registered interventional COVID-19 trial data and concurrently did a prospective observational study of hospitalised patients with COVID-19 who were being assessed for eligibility to one of the RECOVERY, C19-ACS or SIMPLE trials. SETTING: Interventional COVID-19 trial data were analysed from the clinicaltrials.gov and International Standard Randomized Controlled Trial Number databases on 12 July 2020. The patient cohort was taken from five centres in a respiratory National Institute for Health Research network. Population and modelling data were taken from published reports from the UK government and Medical Research Council Biostatistics Unit. PARTICIPANTS: 2082 consecutive admitted patients with laboratory-confirmed SARS-CoV-2 infection from 27 March 2020 were included. MAIN OUTCOME MEASURES: Proportions enrolled, and reasons for exclusion from the aforementioned trials. Comparisons of trial recruitment targets with estimated feasible recruitment numbers. RESULTS: Analysis of trial registration data for COVID-19 treatment studies enrolling in England showed that by 12 July 2020, 29 142 participants were needed. In the observational study, 430 (20.7%) proceeded to randomisation. 82 (3.9%) declined participation, 699 (33.6%) were excluded on clinical grounds, 363 (17.4%) were medically fit for discharge and 153 (7.3%) were receiving palliative care. With 111 037 people hospitalised with COVID-19 in England by 12 July 2020, we determine that 22 985 people were potentially suitable for trial enrolment. We estimate a UK hospitalisation rate of 2.38%, and that another 1.25 million infections would be required to meet recruitment targets of ongoing trials. CONCLUSIONS: Feasible recruitment rates, study design and proliferation of trials can limit the number, and size, that will successfully complete recruitment. We consider that fewer, more appropriately designed trials, prioritising cooperation between centres would maximise productivity in a further wave

    Patterns of myocardial injury in recovered troponin-positive COVID-19 patients assessed by cardiovascular magnetic resonance

    Get PDF
    BACKGROUND: Troponin elevation is common in hospitalized COVID-19 patients, but underlying aetiologies are ill-defined. We used multi-parametric cardiovascular magnetic resonance (CMR) to assess myocardial injury in recovered COVID-19 patients. METHODS AND RESULTS: One hundred and forty-eight patients (64 ± 12 years, 70% male) with severe COVID-19 infection [all requiring hospital admission, 48 (32%) requiring ventilatory support] and troponin elevation discharged from six hospitals underwent convalescent CMR (including adenosine stress perfusion if indicated) at median 68 days. Left ventricular (LV) function was normal in 89% (ejection fraction 67% ± 11%). Late gadolinium enhancement and/or ischaemia was found in 54% (80/148). This comprised myocarditis-like scar in 26% (39/148), infarction and/or ischaemia in 22% (32/148) and dual pathology in 6% (9/148). Myocarditis-like injury was limited to three or less myocardial segments in 88% (35/40) of cases with no associated LV dysfunction; of these, 30% had active myocarditis. Myocardial infarction was found in 19% (28/148) and inducible ischaemia in 26% (20/76) of those undergoing stress perfusion (including 7 with both infarction and ischaemia). Of patients with ischaemic injury pattern, 66% (27/41) had no past history of coronary disease. There was no evidence of diffuse fibrosis or oedema in the remote myocardium (T1: COVID-19 patients 1033 ± 41 ms vs. matched controls 1028 ± 35 ms; T2: COVID-19 46 ± 3 ms vs. matched controls 47 ± 3 ms). CONCLUSIONS: During convalescence after severe COVID-19 infection with troponin elevation, myocarditis-like injury can be encountered, with limited extent and minimal functional consequence. In a proportion of patients, there is evidence of possible ongoing localized inflammation. A quarter of patients had ischaemic heart disease, of which two-thirds had no previous history. Whether these observed findings represent pre-existing clinically silent disease or de novo COVID-19-related changes remain undetermined. Diffuse oedema or fibrosis was not detected

    Performance of reverse osmosis (RO) for water recovery from permeates of membrane bio-reactor (MBR)

    Full text link
    In this study, permeate from a hollow fiber polyethylene (PE) membrane bio-reactor (MBR) system treating synthetic agricultural wastewater was fed into a cellulose acetate brackish water reverse osmosis (BWRO30 2540) membrane system; three different trans-membranes pressures (TMPs) of 1000, 2500, and 4000 kPa were selected to evaluate the system performance in terms of general operating parameters as well as the removal of chosen important potential fouling water quality parameters. The results showed that highest corrected permeate flux rate was at a TMP of 2500 kPa, whereas lowest recorded at a TMP of 4000 kPa. Similar situation prevailed in water recovery rate. But temperature corrected specific fluxes decreased as the applied TMPs increased. In all selected TMPs, more than 96% of salinity was removed. Permeate from MBR as feed to reverse osmosis required frequent chemical cleaning than the microfiltration/ultrafiltration (MF/UF) permeates and granular media filter (GMF) filtered in order to maintain the required rate of product water. One of the reasons for this frequent chemical cleaning is due to higher total organic carbon as well as total nitrogen (TN) in the MBR permeate. This result needs to be further evaluated through field trials. <br /

    Electroanatomic characterization and ablation of scar-related isthmus sites supporting perimitral flutter

    Get PDF
    Objectives The authors reviewed 3-dimensional electroanatomic maps of perimitral flutter to identify scar-related isthmuses and determine their effectiveness as ablation sites. Background Perimitral flutter is usually treated by linear ablation between the left lower pulmonary vein and mitral annulus. Conduction block can be difficult to achieve, and recurrences are common. Methods Patients undergoing atrial tachycardia ablation using CARTO3 (Biosense Webster Inc., Irvine, California) were screened from 4 centers. Patients with confirmed perimitral flutter were reviewed for the presence of scar-related isthmuses by using CARTO3 with the ConfiDense and Ripple Mapping modules. Results Confirmed perimitral flutter was identified in 28 patients (age 65.2 ± 8.1 years), of whom 26 patients had prior atrial fibrillation ablation. Scar-related isthmus ablation was performed in 12 of 28 patients. Perimitral flutter was terminated in all following correct identification of a scar-related isthmus using ripple mapping. The mean scar voltage threshold was 0.11 ± 0.05 mV. The mean width of scar-related isthmuses was 8.9 ± 3.5 mm with a conduction speed of 31.8 ± 5.5 cm/s compared to that of normal left atrium of 71.2 ± 21.5 cm/s (p < 0.0001). Empirical, anatomic ablation was performed in 16 of 28, with termination in 10 of 16 (63%; p = 0.027). Significantly less ablation was required for critical isthmus ablation compared to empirical linear lesions (11.4 ± 5.3 min vs. 26.2 ± 17.1 min; p = 0.0004). All 16 cases of anatomic ablation were reviewed with ripple mapping, and 63% had scar-related isthmus. Conclusions Perimitral flutter is usually easy to diagnose but can be difficult to ablate. Ripple mapping is highly effective at locating the critical isthmus maintaining the tachycardia and avoiding anatomic ablation lines. This approach has a higher termination rate with less radiofrequency ablation required

    An Economic Evaluation of a Streamlined Day-Case Atrial Fibrillation Ablation Protocol and Conventional Cryoballoon Ablation versus Antiarrhythmic Drugs in a UK Paroxysmal Atrial Fibrillation Population

    Get PDF
    Background and Aims Symptom control for atrial fibrillation can be achieved by catheter ablation or drug therapy. We assessed the cost effectiveness of a novel streamlined atrial fibrillation cryoballoon ablation protocol (AVATAR) compared with optimised antiarrhythmic drug (AAD) therapy and a conventional catheter ablation protocol, from a UK National Health Service (NHS) perspective. Methods Data from the AVATAR study were assessed to determine the cost effectiveness of the three protocols in a two-step process. In the first stage, statistical analysis of clinical efficacy outcomes was conducted considering either a three-way comparison (AVATAR vs. conventional ablation vs. optimised AAD therapies) or a two-way comparison (pooled ablation protocol data vs. optimised AAD therapies). In the second stage, models assessed the cost effectiveness of the protocols. Costs and some of the clinical inputs in the models were derived from within-trial cost analysis and published literature. The remaining inputs were derived from clinical experts. Results No significant differences between the ablation protocols were found for any of the clinical outcomes used in the model. Results of a within-trial cost analysis show that AVATAR is cost-saving (£1279 per patient) compared with the conventional ablation protocol. When compared with optimised AAD therapies, AVATAR (pooled conventional and AVATAR ablation protocols efficacy) was found to be more costly while offering improved clinical benefits. Over a lifetime time horizon, the incremental cost-effectiveness ratio of AVATAR was estimated as £21,046 per quality-adjusted life-year gained (95% credible interval £7086–£71,718). Conclusions The AVATAR streamlined protocol is likely to be a cost-effective option versus both conventional ablation and optimised AAD therapy in the UK NHS healthcare setting
    corecore