474 research outputs found

    The CRESST Dark Matter Search

    Full text link
    We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils. The observed count rate in the neutron band is compatible with the rate expected from neutron background. CRESST is presently being upgraded with a 66 channel SQUID readout system, a neutron shield and a muon veto system. This results in a significant improvement in sensitivity.Comment: 6 pages, 3 figures, to be published in the proceedings of the 5th International Workshop on the Identification and Detection of Dark Matter IDM 2004, Edinburgh, Sept. 2004, World Scientifi

    Results from 730 kg days of the CRESST-II Dark Matter Search

    Get PDF
    The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via elastic scattering off nuclei in CaWO4_4 crystals, completed 730 kg days of data taking in 2011. We present the data collected with eight detector modules, each with a two-channel readout; one for a phonon signal and the other for coincidently produced scintillation light. The former provides a precise measure of the energy deposited by an interaction, and the ratio of scintillation light to deposited energy can be used to discriminate different types of interacting particles and thus to distinguish possible signal events from the dominant backgrounds. Sixty-seven events are found in the acceptance region where a WIMP signal in the form of low energy nuclear recoils would be expected. We estimate background contributions to this observation from four sources: 1) "leakage" from the e/\gamma-band 2) "leakage" from the \alpha-particle band 3) neutrons and 4) Pb-206 recoils from Po-210 decay. Using a maximum likelihood analysis, we find, at a high statistical significance, that these sources alone are not sufficient to explain the data. The addition of a signal due to scattering of relatively light WIMPs could account for this discrepancy, and we determine the associated WIMP parameters.Comment: 17 pages, 13 figure

    Self-Dual Bending Theory for Vesicles

    Full text link
    We present a self-dual bending theory that may enable a better understanding of highly nonlinear global behavior observed in biological vesicles. Adopting this topological approach for spherical vesicles of revolution allows us to describe them as frustrated sine-Gordon kinks. Finally, to illustrate an application of our results, we consider a spherical vesicle globally distorted by two polar latex beads.Comment: 10 pages, 3 figures, LaTeX2e+IOPar

    The CRESST Experiment: Recent Results and Prospects

    Get PDF
    The CRESST experiment seeks hypothetical WIMP particles that could account for the bulk of dark matter in the Universe. The detectors are cryogenic calorimeters in which WIMPs would scatter elastically on nuclei, releasing phonons. The first phase of the experiment has successfully deployed several 262 g sapphire devices in the Gran Sasso underground laboratories. A main source of background has been identified as microscopic mechanical fracturing of the crystals, and has been eliminated, improving the background rate by up to three orders of magnitude at low energies, leaving a rate close to one count per day per kg and per keV above 10 keV recoil energy. This background now appears to be dominated by radioactivity, and future CRESST scintillating calorimeters which simultaneously measure light and phonons will allow rejection of a great part of it.Comment: To appear in the proceedings of the CAPP2000 Conference, Verbier, Switzerland, July, 2000 (eds J. Garcia-Bellido, R. Durrer, and M. Shaposhnikov

    Detection of the Natural Alpha Decay of Tungsten

    Full text link
    The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the simultaneous measurement of phonon and light signals with the CRESST cryogenic detectors. A half-life of T1/2 = (1.8 +- 0.2) x 10^18 y and an energy release of Q = (2516.4 +- 1.1 (stat.) +- 1.2 (sys.)) keV have been measured. New limits are also set on the half-lives of the other naturally occurring tungsten isotopes.Comment: Submitted to Physical Review C Revised versio

    Status of the CRESST Dark Matter Search

    Full text link
    The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edge sensors. In addition, a small fraction of the interaction energy is emitted from the crystals in the form of scintillation light which is measured in coincidence with the phonon signal by a separate cryogenic light detector for each target crystal. The ratio of light to phonon energy permits the discrimination between the nuclear recoils expected from WIMPs and events from radioactive backgrounds which primarily lead to electron recoils. CRESST has shown the success of this method in a commissioning run in 2007 and, since then, further investigated possibilities for an even better suppression of backgrounds. Here, we report on a new class of background events observed in the course of this work. The consequences of this observation are discussed and we present the current status of the experiment.Comment: Proceedings of the 13th International Workshop on Low Temperature Detectors, 4 pages, 3 figure

    Composite CaWO4 Detectors for the CRESST-II Experiment

    Full text link
    CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.Comment: Proceedings of the Thirteenth International Workshop on Low Temperature Detectors 4 pages, 9 figure

    Energy-dependent light quenching in CaWO4 crystals at mK temperatures

    Get PDF
    Scintillating CaWO4 single crystals are a promising multi-element target for rare-event searches and are currently used in the direct dark matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO4 is quantified by quenching factors (QFs). These are essential for an active background discrimination and the identification of a possible signal induced by weakly interacting massive particles (WIMPs). We present the first precise measurements of the QFs of O, Ca and W at mK temperatures by irradiating a cryogenic detector with a fast neutron beam. A clear energy dependence of the QF of O and, less pronounced, of Ca was observed for the first time. Furthermore, in CRESST neutron-calibration data a variation of the QFs among different CaWO4 single crystals was found. For typical CRESS
    corecore