12 research outputs found

    Inaccurate level of intervertebral space estimated by palpation: The ultrasonic revelation

    No full text
    Background: Spinal cord injury resulting from spinal anesthesia is a rare, but an alarming scenario. The most likely cause is believed to be misjudged level of intervertebral space (IVS). We evaluated the accuracy of palpation method to locate IVS with the ultrasonography. Materials and Methods: A total of 109 patients undergoing spinal anesthesia were included in this observational, double-blind study. First anesthesiologist was asked to mark IVS using palpation method. It was followed by ultrasonographic assessment by another anesthesiologist who was unaware of the level estimated for the mark. We evaluated the accuracy of palpation method in sitting and lateral position as well as the impact of the anesthesiologist′s experience (Trainee/Consultant). Statistical Analysis Used: Association between the gender, anthropometric parameters, type of anesthesiologists assessing the IVS, and the level of agreement were identified using Chi-square test. The agreement between palpation method and ultrasound assessment of IVS was analyzed using kappa statistic. P < 0.05 was defined as statistical significance. Results: The IVS located by palpation method was in agreement with ultrasound location in 37.14% of the patients. There were no statistically significant differences found in terms of demographic data (sex, age, height, weight, or body mass index [BMI]) between agreement and disagreement group. The rate of errors was found to be significantly higher (P = 0.01) among the trainees (74.51%) than the consultants (51.86%). The rate of errors was not different between the sitting and lateral position. The frequency of errors was more common in cephalad direction (53.31.5%) compared to caudal direction (9.52%). The misidentified spaces were as high as three spaces above the intended space while in caudal direction it differed by only one space. Conclusion: The accuracy of palpation method controlled by ultrasound is 37.14% and differs by 1-3 IVS in cephalad direction (53.31%). The accuracy is affected by anesthesiologist′s experience but remains unaffected by age, sex height, BMI, and patient positioning

    The effect of addition of low dose fentanyl to epidural bupivacaine (0.5%) in patients undergoing elective caesarean section: A randomized, parallel group, double blind, placebo controlled study

    No full text
    Background: Opioids have synergistic action with local anesthetics which may alter characteristics of epidural block. Giving opioids to mother before delivery of baby is still fully not accepted with some fearing risk of neonatal depression. Aims: Our primary aim was to evaluate the analgesic effect of addition of 50 μg fentanyl to epidural 0.5% bupivacaine in patients undergoing elective caesarean section using visual analog scale. The secondary aim was to assess onset of analgesia, volume of drug required to achieve T6 level, grade and duration of motor block and Apgar score. Materials and Methods: In this prospective, randomized, double blind, placebo controlled study 64 patients scheduled for elective caesarean section under epidural anesthesia were randomly divided into two groups of 32 each. The fentanyl group received 1ml of 50 μg fentanyl and the saline group received 1ml of normal saline mixed with 10ml of 0.5% bupivacaine for epidural anesthesia. VAS score, time to achieve T6 level, dose of bupivacaine, intraoperative analgesic consumption and duration of analgesia, grade and duration of motor block and any adverse maternal and neonatal effects were noted. Statistical Analysis: Data was analyzed using Students t test, chi-square test and Mann-Whitney U-test. The values of P < 0.05 were considered statistically significant. Results: Fentanyl improved the VAS score significantly (1.6 ± 1.32) compared to the saline group (3.77 ± 1.0, P < 0.0001). It also reduced the intraoperaitve analgesic supplementation compared to the saline group. (P = 0.031). The postoperative duration of analgesia was prolonged in the fentanyl group (275.80 ± 13.61 min) compared to the saline group (191.47 ± 12.16 min, P < 0.0001). The other characteristics of epidural block were unaltered. Conclusion: Addition of 50 μg fentanyl to epidural 0.5% bupivacaine significantly reduces the VAS score. It also reduces intra-operative analgesia supplementation and prolongs the duration of postoperative analgesia without altering the other characteristics of block. The neonatal outcome is not affected with addition of fentanyl before delivery of baby

    Comparison of electrical resistivity by geophysical method and neutron probe logging for soil moisture monitoring in a forested watershed

    No full text
    Geophysical methods are becoming more popular nowadays in the field of hydrology due to their time and space efficiency. So an attempt has been made here to relate electrical resistivity with soil moisture content in the field. The experiments were carried out in an experimental watershed 'Mulehole' in southern India, which is a forested watershed with approximately 80% red soil. Five auger holes were drilled to perform the soil moisture and electrical resistivity measurements in a toposequence having red and black soils, with sandy weathered soil at the bottom. Soil moisture was measured using neutron probe and electrical resistivity was measured using electrical logging tool. The results indicate that electrical resistivity measurements can be used to measure soil moisture content for red soils only
    corecore