6,477 research outputs found

    Gas diffusion liquid storage bag and method of use for storing blood

    Get PDF
    The shelf life of stored whole blood may be doubled by adding a buffer which maintains a desired pH level. However, this buffer causes the generation of CO2 which, if not removed at a controlled rate, causes the pH value of the blood to decrease, which shortens the useful life of the blood. A blood storage bag is described which permits the CO2 to be diffused out at a controlled rate into the atmosphere, thereby maintaining the desired pH value and providing a bag strong enough to permit handling

    Noise processes in nanomechanical resonators

    Get PDF
    Nanomechanical resonators can be fabricated to achieve high natural resonance frequencies, approaching 1 GHz, with quality factors in excess of 10^(4). These resonators are candidates for use as highly selective rf filters and as precision on-chip clocks. Some fundamental and some nonfundamental noise processes will present limits to the performance of such resonators. These include thermomechanical noise, Nyquist-Johnson noise, and adsorption-desorption noise; other important noise sources include those due to thermal fluctuations and defect motion-induced noise. In this article, we develop a self-contained formalism for treating these noise sources, and use it to estimate the impact that these noise processes will have on the noise of a model nanoscale resonator, consisting of a doubly clamped beam of single-crystal Si with a natural resonance frequency of 1 GHz

    Fabrication of high frequency nanometer scale mechanical resonators from bulk Si crystals

    Get PDF
    We report on a method to fabricate nanometer scale mechanical structures from bulk, single-crystal Si substrates. A technique developed previously required more complex fabrication methods and an undercut step using wet chemical processing. Our method does not require low pressure chemical vapor deposition of intermediate masking layers, and the final step in the processing uses a dry etch technique, avoiding the difficulties encountered from surface tension effects when wet processing mechanically delicate or large aspect ratio structures. Using this technique, we demonstrate fabrication of a mechanical resonator with a fundamental resonance frequency of 70.72 MHz and a quality factor of 2 x 10^(4)

    The long-term prognostic significance of 6-minute walk test distance in patients with chronic heart failure

    Get PDF
    Background. The 6-minute walk test (6-MWT) is used to assess patients with chronic heart failure (CHF). The prognostic significance of the 6-MWT distance during long-term followup ( > 5 years) is unclear. Methods. 1,667 patients (median [inter-quartile range, IQR]) (age 72 [65-77] ; 75% males) with heart failure due to left ventricular systolic impairment undertook a 6-MWT as part of their baseline assessment and were followed up for 5 years. Results. At 5 years' followup, those patients who died (n = 959) were older at baseline and had a higher log NT pro-BNP than those who survived to 5 years (n = 708). 6-MWT distance was lower in those who died [163 (153) m versus 269 (160) m; P 360 m. 6-MWT distance was a predictor of all-cause mortality (HR 0.97; 95% CI 0.96-0.97; Chi-square = 184.1; P < 0.0001). Independent predictors of all-cause mortality were decreasing 6-MWT distance, increasing age, increasing NYHA classification, increasing log NT pro-BNP, decreasing diastolic blood pressure, decreasing sodium, and increasing urea. Conclusion. The 6-MWT is an important independent predictor of all-cause mortality following long-term followup in patients with CHF. © 2014 Lee Ingle et al

    Metastability and the Casimir Effect in Micromechanical Systems

    Full text link
    Electrostatic and Casimir interactions limit the range of positional stability of electrostatically-actuated or capacitively-coupled mechanical devices. We investigate this range experimentally for a generic system consisting of a doubly-clamped Au suspended beam, capacitively-coupled to an adjacent stationary electrode. The mechanical properties of the beam, both in the linear and nonlinear regimes, are monitored as the attractive forces are increased to the point of instability. There "pull-in" occurs, resulting in permanent adhesion between the electrodes. We investigate, experimentally and theoretically, the position-dependent lifetimes of the free state (existing prior to pull-in). We find that the data cannot be accounted for by simple theory; the discrepancy may be reflective of internal structural instabilities within the metal electrodes.Comment: RevTex, 4 pages, 4 figure

    Performance of silicon solar cell assemblies

    Get PDF
    Solar cell assembly current-voltage characteristics, thermal-optical properties, and power performance were determined. Solar cell cover glass thermal radiation, optical properties, confidence limits, and temperature intensity effects on maximum power were discussed

    Abnormalities of the ventilatory equivalent for carbon dioxide in patients with chronic heart failure

    Get PDF
    Introduction. The relation between minute ventilation (VE) and carbon dioxide production (VCO2) can be characterised by the instantaneous ratio of ventilation to carbon dioxide production, the ventilatory equivalent for CO2 (VEqCO2). We hypothesised that the time taken to achieve the lowest VEqCO2 (time to VEqCO2 nadir) may be a prognostic marker in patients with chronic heart failure (CHF). Methods. Patients and healthy controls underwent a symptom-limited, cardiopulmonary exercise test (CPET) on a treadmill to volitional exhaustion. Results. 423 patients with CHF (mean age 63±12 years; 80% males) and 78 healthy controls (62% males; age 61±11 years) were recruited. Time to VEqCO2 nadir was shorter in patients than controls (327±204 s versus 514±187 s; P=0.0001). Univariable predictors of all-cause mortality included peak oxygen uptake (X 2 =53.0), VEqCO2 nadir (X 2 =47.9), and time to VEqCO2 nadir (X 2 =24.0). In an adjusted Cox multivariable proportional hazards model, peak oxygen uptake (X 2 =16.7) and VEqCO2 nadir (X 2 =17.9) were the most significant independent predictors of all-cause mortality. Conclusion. The time to VEqCO2 nadir was shorter in patients with CHF than in normal subjects and was a predictor of subsequent mortality. © 2012 Lee Ingle et al

    Spintronics of a Nanoelectromechanical Shuttle

    Full text link
    We consider effects of the spin degree of freedom on the nanomechanics of a single-electron transistor (SET) containing a nanometer-sized metallic cluster suspended between two magnetic leads. It is shown that in such a nanoelectromechanical SET(NEM-SET) the onset of an electromechanical instability leading to cluster vibrations and "shuttle" transport of electrons between the leads can be controlled by an external magnetic field. Different stable regimes of this spintronic NEM-SET operation are analyzed. Two different scenarios for the onset of shuttle vibrations are found.Comment: 4 pages, 3 figure
    corecore