247 research outputs found

    Extended Focus Range High Resolution Endoscopic Optical Coherence Tomography

    Get PDF
    Today, medical imaging is playing an important role in medicine as it provides the techniques and processes used to create images of the human body or parts thereof for clinical purposes (medical procedures seeking to reveal, diagnose or examine disease) or medical science (including the study of normal anatomy and function). Modalities are developing over time to achieve the highest possible resolution, speed of image acquisition, sensitivity, and specificity. In the past decade, advances in optics, fiber, as well as laser technology have enabled the development of noninvasive optical biomedical imaging technology that can also be applied to endoscopy to reach deeper locations in the human body. The purpose of this dissertation is to investigate a full system design and optimization of an optical coherence tomography (OCT) system to achieve high axial and lateral resolution together with an extended depth of focus for endoscopic in vivo imaging. In this research aimed at advancing endoscopic OCT imaging, two high axial resolution optical coherence tomography systems were developed: (1) a spectrometer-based frequency-domain (FD) OCT achieving an axial resolution of ~2.5 µm using a Ti:Sa femtosecond laser with a 120nm bandwidth centered at 800nm and (2) a swept-source based FD OCT employing a high speed Fourier domain mode locked (FDML) laser that achieves real time in vivo imaging with ~8 µm axial resolution at an acquisition speed of 90,000 A-scans/sec. A critical prior limitation of FD OCT systems is the presence of mirror images in the image reconstruction algorithm that could only be eliminated at the expense of depth and speed of imaging. A key contribution of this research is the development of a novel FD OCT imager that enables full range depth imaging without a loss in acquisition speed. Furthermore, towards the need for better axial resolution, we developed a mathematical model of the OCT signal that includes the effect on phase modulation of phase delay, group delay, and dispersion. From the mathematical model we saw that a Fourier domain optical delay line (FD ODL) incorporated into the reference arm of the OCT system represented a path to higher performance. Here we then present a method to compensate for overall system dispersion with a FDODL that maintains the axial resolution at the limit determined solely by the coherence length of a broadband source. In the development of OCT for endoscopic applications, the need for long depth of focus imaging is critical to accommodate the placement of the catheter anywhere within a vessel. A potential solution to this challenge is Bessel-beam imaging. In a first step, a Bessel-beam based confocal scanning optical microscopy (BCSOM) using an axicon and single mode fiber was investigated with a mathematical model and simulation. The BCSOM approach was then implemented in a FD OCT system that delivered high lateral resolution over a long depth of focus. We reported on the imaging in biological samples for the first time with a double-pass microoptics axicon that demonstrated clearly invariant SNR and 8 um lateral resolution images across a 4 mm depth of focus. Finally, we describe the design and fabrication of a catheter incorporated in the FD OCT. The design, conceived for a 5 mm outer diameter catheter, allows 360 degree scanning with a lateral resolution of about 5 um across a depth of focus of about 1.6 mm. The dissertation concludes with comments for related future work

    Systems and Methods for Generating a Tunable Laser Beam

    Get PDF
    The invention is an extended tuning range frequency swept laser, which can be applied to either a fiber ring cavity or a linear cavity configuration. However, in this description, we will focus on a fiber ring cavity configuration which uses a fiber couple semiconductor optical amplifier (SOA) as a gain medium and a tunable filter to scan an output frequency through the bandwidth of the SOA

    Under-reporting of Energy Intake from 24-hour Dietary Recalls in the Korean National Health and Nutrition Examination Survey

    Get PDF
    AbstractObjectivesChronic degenerative diseases are closely related to daily eating habits, nutritional status, and, in particular, energy intake. In clarifying these relationships it is very important for dietary surveys to report accurate information about energy intake. This study attempted to identify the prevalence of the under-reporting of energy intake and its related characteristics based on the Korean National Health and Nutrition Examination Survey conducted in the years 2007–2009.MethodsThe present study analyzed dietary intake data from 15,133 adults aged ≥19 years using 24-hour dietary recalls. Basal metabolic rates were calculated from the age- and gender-specific equations of Schofield and under-reporting was defined as an energy intake <0.9, represented by the ratio of energy intake to estimated basal metabolic rate.ResultsUnder-reporters (URs) accounted for 14.4% of men and 23.0% of women and the under-reporting rate was higher in the age group 30–49 years for both men and women. The results from an analysis of the age-specific socioeconomic characteristics of participants classified as URs showed that under-reporting was high in women living alone and in women with only elementary school education or no education. The results from an analysis of the health-specific characteristics of URs showed that a large proportion of URs had poor self-rated health or were obese, or both, compared with non-URs. The proportion of participants who consumed less than the estimated average requirements for nutrients was significantly higher in URs compared with non-URs.ConclusionThe under-reporting of energy intake was associated with age, gender, education level, income level, household status (single-person or multi-person), self-rated health, physical activity, and obesity

    Purification and characterization of angiotensin-1 converting enzyme (ACE)-inhibitory peptide from the jellyfish, Nemopilema nomurai

    Get PDF
    The Nemopilema nomurai hydrolysate was produced by the reaction of papain, and an angiotensin-Ι converting enzyme (ACE)-inhibitory peptide was purified by using the molecular cut-offs membrane filter, the gel filtration chromatography with Sephadex LH-20 and the reverse phase chromatographic method using C18 and C12 columns. Purification yield of the active peptide was estimated to be 0.2 ± 0.1%, starting from the lyophilized jellyfish. The infrared (IR), proton nuclear magnetic resonance spectroscopy (1H NMR), carbon nuclear magnetic resonance (13C NMR) and mass spectrometry (MS) spectrometer analyses elucidated that the structure of the purified peptide is tyrosine-isoleucine (Tyr-Ile). The inhibitory concentration at 50% (IC50) and Ki values were calculated to be 2.0 ± 0.3 μg/ml and 3.3 ± 0.3 μM, respectively, which acts as a competitive inhibitor to ACE.Keywords: Angiotensin-Ι converting enzyme, Jellyfish, Nemopilema nomurai, Papain hydrolysate, Tyrosine-IsoleucineAfrican Journal of Biotechnology Vol. 12(15), pp. 1888-189
    • …
    corecore