9 research outputs found

    CCQM-K90, formaldehyde in nitrogen, 2 μmol mol− 1 Final report

    Get PDF
    The CCQM-K90 comparison is designed to evaluate the level of comparability of national metrology institutes (NMI) or designated institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 μmol mol−1. The comparison was organised by the BIPM using a suite of gas mixtures prepared by a producer of specialty calibration gases. The BIPM assigned the formaldehyde mole fraction in the mixtures by comparison with primary mixtures generated dynamically by permeation coupled with continuous weighing in a magnetic suspension balance. The BIPM developed two dynamic sources of formaldehyde in nitrogen that provide two independent values of the formaldehyde mole fraction: the first one based on diffusion of trioxane followed by thermal conversion to formaldehyde, the second one based on permeation of formaldehyde from paraformaldehyde contained in a permeation tube. Two independent analytical methods, based on cavity ring down spectroscopy (CRDS) and Fourier transform infrared spectroscopy (FTIR) were used for the assignment procedure. Each participating institute was provided with one transfer standard and value assigned the formaldehyde mole fraction in the standard based on its own measurement capabilities. The stability of the formaldehyde mole fraction in transfer standards was deduced from repeated measurements performed at the BIPM before and after measurements performed at participating institutes. In addition, 5 control standards were kept at the BIPM for regular measurements during the course of the comparison. Temporal trends that approximately describe the linear decrease of the amount-of-substance fraction of formaldehyde in nitrogen in the transfer standards over time were estimated by two different mathematical treatments, the outcomes of which were proposed to participants. The two treatments also differed in the way measurement uncertainties arising from measurements performed at the BIPM were propagated to the uncertainty of the trend parameters, as well as how the dispersion of the dates when measurements were made by the participants was taken into account. Upon decision of the participants, the Key Comparison Reference Values were assigned by the BIPM using the largest uncertainty for measurements performed at the BIPM, linear regression without weight to calculate the trend parameters, and not taking into account the dispersion of dates for measurements made by the participant. Each transfer standard was assigned its own reference value and associated expanded uncertainty. An expression for the degree of equivalence between each participating institute and the KCRV was calculated from the comparison results and measurement uncertainties submitted by participating laboratories. Results of the alternative mathematical treatment are presented in annex of this report

    Обеспечение прослеживаемости результатов измерений содержания загрязняющих веществ в промышленных выбросах автоматическими измерительными системами

    Get PDF
    The results of the development of a gas mixing and analytical stand (reference complex) for testing in order to approve the type of automatic measuring systems (AMS) for determining the content of pollutants in industrial emissions are presented. During the use of the AMS test bench, the units of molar fraction and mass concentration are transferred from the State primary standard of units of molar fraction, mass fraction and mass concentration of components in gas and gas condensate media GET 154 to the tested measuring gas channels of AMS, thereby ensuring traceability of AMS measurement results to the State primary standard GET 154.В статье представлены результаты разработки газосмесительно-аналитического стенда (эталонного комплекса) для проведения испытаний в целях утверждения типа автоматических измерительных систем (АИС) для определения содержания загрязняющих веществ в промышленных выбросах. В процессе использования стенда для испытаний АИС осуществляется передача единиц молярной доли и массовой концентрации от государственного первичного эталона единиц молярной доли, массовой доли и массовой концентрации компонентов в газовых и газоконденсатных средах ГЭТ 154 испытуемым газоаналитическим измерительным каналам АИС, обеспечивая тем самым прослеживаемость результатов измерений АИС к государственному первичному эталону ГЭТ 154

    CCQM-K120 (Carbon dioxide at background and urban level)

    No full text
    CCQM-K120.a comparison involves preparing standards of carbon dioxide in air which are fit for purpose for the atmospheric monitoring community, with stringent requirements on matrix composition and measurement uncertainty of the CO2 mole fraction. This represents an analytical challenge and is therefore considered as a Track C comparison. The comparison will underpin CMC claims for CO2 in air for standards and calibrations services for the atmospheric monitoring community, matrix matched to real air, over the mole fraction range of 250 μmol/mol to 520 μmol/mol. CCQM-K120.b comparison tests core skills and competencies required in gravimetric preparation, analytical certification and purity analysis. It is considered as a Track A comparison. It will underpin CO2 in air and nitrogen claims in a mole fraction range starting at the smallest participant's reported expanded uncertainty and ending at 500 mmol/mol. Participants successful in this comparison may use their result in the flexible scheme and underpin claims for all core mixtures This study has involved a comparison at the BIPM of a suite of 44 gas standards prepared by each of the participating laboratories. Fourteen laboratories took part in both comparisons (CCQM-K120.a, CCQM-K120.b) and just one solely in the CCQM-K120.b comparison. The standards were sent to the BIPM where the comparison measurements were performed. Two measurement methods were used to compare the standards, to ensure no measurement method dependant bias: GC-FID and FTIR spectroscopic analysis corrected for isotopic variation in the CO2 gases, measured at the BIPM using absorption laser spectroscopy. Following the advice of the CCQM Gas Analysis Working Group, results from the FTIR method were used to calculate the key comparison reference values

    International Comparison CCQM-K51 - Carbon Monoxide (CO) in Nitrogen (5 µmol mol-1)

    No full text
    The first key comparison on carbon monoxide (CO) in nitrogen dates back to 1992 (CCQM-K1a). It was one of the first types of gas mixtures that were used in an international key comparison. Since then, numerous national metrology institutes (NMIs) have been setting up facilities for gas analysis, and have developed claims for their Calibration and Measurement Capabilities (CMCs) for these mixtures. Furthermore, in the April 2005 meeting of the CCQM (Consultative Committee for Amount of Substance) Gas Analysis Working Group, a policy was proposed to repeat key comparisons for stable mixtures every 10 years. This comparison was performed in line with the policy proposal and provided an opportunity for NMIs that could not participate in the previous comparison. NMISA from South Africa acted as the pilot laboratory. Of the 25 participating laboratories, 19 (76%) showed satisfactory degrees of equivalence to the gravimetric reference value. The results show that the CO concentration is not influenced by the measurement method used, and from this it may be concluded that the pure CO, used to prepare the gas mixtures, was not 13C-isotope depleted. This was confirmed by the isotope ratio analysis carried out by KRISS on a 1% mixture of CO in nitrogen, obtained from the NMISA. There is no indication of positive or negative bias in the gravimetric reference value, as the results from the different laboratories are evenly distributed on both sides of the key comparison reference value.JRC.H.2-Air and Climat