30 research outputs found

    Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry: The EFFORTLESS Study.

    Get PDF
    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. OBJECTIVES: The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. METHODS: This is the first report on the full patient cohort and study endpoints with follow-up ≥1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. RESULTS: Patients were followed for 3.1 ± 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 ± 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. CONCLUSIONS: This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (Evaluation oF Factors ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD [The EFFORTLESS S-ICD Registry]; NCT01085435)

    Subcutaneous implantable cardioverter-defibrillators: long-term results of the EFFORTLESS study

    Get PDF
    AIMS: To report 5-year outcomes of EFFORTLESS registry patients with early generation subcutaneous implantable cardioverter-defibrillator (S-ICD) devices. METHODS AND RESULTS: Kaplan-Meier, trend and multivariable analyses were performed for mortality and late (years 2-5) complications, appropriate shock (AS) and inappropriate shock (IAS) rates. Nine hundred and eighty-four of 994 enrolled patients with diverse diagnoses (28% female, 48 ± 17 years, body mass index 27 ± 6 kg/m2, ejection fraction 43 ± 18%) underwent S-ICD implantation. Median follow-up was 5.1 years (interquartile range 4.7-5.5 years). All-cause mortality was 9.3% (95% confidence interval 7.2-11.3%) at 5 years; 703 patients remained in follow-up on study completion, 171 withdrew including 87 (8.8%) with device explanted, and 65 (6.6%) lost to follow-up. Of the explants, only 20 (2.0%) patients needed a transvenous device for pacing indications. First and final shock efficacy for discrete ventricular arrhythmias was consistent at 90% and 98%, respectively, with storm episode final shock efficacy at 95.2%. Time to therapy remained unaltered. Overall 1- and 5-year complication rates were 8.9% and 15.2%, respectively. Early complications did not predict later complications. There were no structural lead failures. Inappropriate shock rates at 1 and 5 years were 8.7% and 16.9%, respectively. Self-terminating inappropriately sensed episodes predicted late IAS. Predictors of late AS included self-terminating appropriately sensed episodes and earlier AS. CONCLUSION: In this diverse S-ICD registry population, spontaneous shock efficacy was consistently high over 5 years. Very few patients underwent S-ICD replacement with a transvenous device for pacing indications. Treated and self-terminating arrhythmic episodes predict future shock events, which should encourage more personalized device optimization. KEY QUESTION: Is subcutaneous implantable cardioverter-defibrillator (S-ICD) shock efficacy maintained over time? KEY FINDING: Subcutaneous implantable cardioverter-defibrillator shock efficacy remains high for discrete and storm episodes. For discrete episodes first and final shock efficacy do not change over time or by rhythm type. TAKE-HOME MESSAGE: The EFFORTLESS study 5-year results provide the longest follow up of a large patient cohort implanted with the S-ICD. For 984 patients with a median follow-up of 5.1 years, the S-ICD maintains a high level of shock efficacy of 98%

    Subcutaneous or Transvenous Defibrillator Therapy.

    Get PDF
    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.)

    Efficacy and Safety of Appropriate Shocks and Antitachycardia Pacing in Transvenous and Subcutaneous Implantable Defibrillators: Analysis of All Appropriate Therapy in the PRAETORIAN Trial.

    Get PDF
    BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022

    A comprehensive individual patient data meta-analysis of the effects of cardiac contractility modulation on functional capacity and heart failure-related quality of life

    No full text
    Aims: Cardiac contractility modulation, also referred to as CCMâ„¢, has emerged as a promising device treatment for heart failure (HF) in patients not indicated for cardiac resynchronization therapy. We performed a comprehensive individual patient data meta-analysis of all non-confounded prospective randomized controlled trials of CCM vs. control that have measured functional capacity and/or quality of life questionnaires in patients with HF. Methods and results: The Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE were searched in January 2020 to identify eligible randomized controlled trials. We also asked the sole manufacturer of the device for their list of known trials. Primary outcomes of interest were peak oxygen consumption (peak VO2 ), 6 min walk test distance, and quality of life measured by Minnesota Living with Heart Failure Questionnaire (MLWHFQ), and all data were received as individual patient and individual time point data-points. Mean differences and 95% confidence intervals (CIs) were calculated for continuous data using a fixed-effects model. Five trials were identified, four randomized studies enrolling 801 participants for all endpoints of interest, and for peak VO2 alone (n = 60), there was an additional single arm non-randomized trial (FIX-HF-5C2) with a prospective comparison of its 24 week peak VO2 data compared with the control group of the FIX-HF-5C control patients. Pooled analysis showed that, compared with control, CCM significantly improved peak VO2 (mean difference +0.93, 95% CI 0.56 to 1.30 mL/kg/min, P < 0.00001), 6 min walk test distance (mean difference +17.97, 95% CI 5.48 to 30.46 m, P = 0.005), and quality of life measured by MLWHFQ (mean difference -7.85, 95% CI -10.76 to -4.94, P < 0.00001). As a sensitivity analysis, we excluded the FIX-HF-5C2 trial (only relevant for peak VO2 ), and the result was similar, mean difference +0.65, 95% CI 0.21 to 1.08 mL/kg/min, P = 0.004. Conclusions: This comprehensive meta-analysis of individual patient data from all known randomized trials has shown that CCM provides statistically significant and clinically meaningful benefits in measures of functional capacity and HF-related quality of life

    Incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias in high risk coronary patients and prophylactic implantation of a defibrillator

    No full text
    Objectives: To assess the incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias after implantable cardioverter-defibrillator (ICD) implantation for primary prevention. Design: Prospective observational study. Patients: 41 consecutive patients, who fulfilled MADIT (multicenter automatic defibrillator implantation trial) I criteria, except for suppressibility by procainamide, and who received a prophylactic ICD. Interventions: Subpectoral implantation of an ICD. Main outcome measures: Incidence of ventricular tachyarrhythmias and their electrophysiological characteristics with respect to timing of the arrhythmia, tachyarrhythmia cycle length, mode of termination, and clinical relevance. Results: During a mean (SD) follow up of 30 (21) months 18 of 41 (43.9%) patients experienced 142 appropriate ICD treatments. The mean (SD) time to first event was 9.6 (15.1) months. One patient had ventricular fibrillation (VF), 12 patients ventricular tachycardia (VT), and five both VT and VF. The mean (SD) cycle length of monomorphic VT was 306 (42) ms. Of 142 episodes, 117 (82.3%) were terminated by antitachycardia pacing and another 25 (17.6%) by ICD discharges. Cumulative survival of hypothetical death, defined as treated VT with a cycle length < 260 ms or VF, was 83.2% after one year and 78.4% after two years. Conclusions: Patients with a left ventricular ejection fraction < 35%, a history of myocardial infarction, non-sustained VT, and inducible VT/VF are at high risk of VT/VF early after implantation. Therefore, implantation of a tiered treatment defibrillator seems to be justified

    Sex differences of in-hospital outcome and long-term mortality in patients with Takotsubo cardiomyopathy

    No full text
    KJ Weidner,1,* I El-Battrawy,1,2,* M Behnes,1 K Schramm,1 C Fastner,1,2 J Kuschyk,1 U Hoffmann,1,2 U Ansari,1 M Borggrefe,1,2 I Akin1,2 1First Department of Medicine, University Medical Centre Mannheim, Faculty of Medicine Mannheim, University of Heidelberg, 2DZHK (German Center for Cardiovascular Research), Partner Site, Heidelberg, Mannheim, Germany *These authors contributed equally to this work Background: Previous studies revealed that patients with Takotsubo cardiomyopathy (TTC) have a higher mortality rate than the general population. It is still unclear whether sex differences may influence long-term prognosis of TTC patients. The purpose of this study was to determine whether sex differences do influence the short- and long-term outcomes of TTC. Methods and results: A total of 114 patients with TTC were admitted to the University Medical Centre Mannheim from January 2003 to September 2015 and entered into the TTC database of the University Medical Centre Mannheim, and retrospectively analyzed. Patients were diagnosed by the Mayo Clinic criteria. All-cause mortality over mean follow-up of 1,529&plusmn;1,121&nbsp;days was revealed. Significantly more male patients died within long-term follow-up compared to female TTC patients (log-rank test; P=0.01). Most males died of noncardiac causes. In multivariate Cox regression analysis, the male sex (P=0.02, hazard ratio [HR] 2.8, 95% CI 1.1&ndash;7.2), the ejection fraction &le;35% (P=0.01, HR 3.3, 95% CI 1.2&ndash;9.2) and glomerular filtration rate &lt;60&nbsp;mL/min (P&lt;0.01, HR 3.1, 95% CI 1.4&ndash;7.0) figured out as independent predictors of the adverse outcome. Conclusion: This study shows that males suffering from TTC reveal a higher long-term all-cause mortality rate than females over a 5 year follow-up period. Keywords: Takotsubo cardiomyopathy, sex differences, outcome, mortality&nbsp

    Subcutaneous implantable cardioverter-defibrillators: long-term results of the EFFORTLESS study

    No full text
    AIMS: To report 5-year outcomes of EFFORTLESS registry patients with early generation subcutaneous implantable cardioverter-defibrillator (S-ICD) devices. METHODS AND RESULTS: Kaplan-Meier, trend and multivariable analyses were performed for mortality and late (years 2-5) complications, appropriate shock (AS) and inappropriate shock (IAS) rates. Nine hundred and eighty-four of 994 enrolled patients with diverse diagnoses (28% female, 48 ± 17 years, body mass index 27 ± 6 kg/m2, ejection fraction 43 ± 18%) underwent S-ICD implantation. Median follow-up was 5.1 years (interquartile range 4.7-5.5 years). All-cause mortality was 9.3% (95% confidence interval 7.2-11.3%) at 5 years; 703 patients remained in follow-up on study completion, 171 withdrew including 87 (8.8%) with device explanted, and 65 (6.6%) lost to follow-up. Of the explants, only 20 (2.0%) patients needed a transvenous device for pacing indications. First and final shock efficacy for discrete ventricular arrhythmias was consistent at 90% and 98%, respectively, with storm episode final shock efficacy at 95.2%. Time to therapy remained unaltered. Overall 1- and 5-year complication rates were 8.9% and 15.2%, respectively. Early complications did not predict later complications. There were no structural lead failures. Inappropriate shock rates at 1 and 5 years were 8.7% and 16.9%, respectively. Self-terminating inappropriately sensed episodes predicted late IAS. Predictors of late AS included self-terminating appropriately sensed episodes and earlier AS. CONCLUSION: In this diverse S-ICD registry population, spontaneous shock efficacy was consistently high over 5 years. Very few patients underwent S-ICD replacement with a transvenous device for pacing indications. Treated and self-terminating arrhythmic episodes predict future shock events, which should encourage more personalized device optimization
    corecore