134 research outputs found

    A rare, highly aggressive primitive neuroectodermal tumor of the kidney: Case report and literature review

    Get PDF
    AbstractWe report a case of a 14-year-old boy who initially suffered from a sudden onset of abdominal pain for 2 weeks with a protrusive soft mass over the left upper abdomen. No obvious symptomatic symptoms or body weight loss were observed. However, early lung metastasis was detected after an initial computed tomographic examination. Even after we performed salvage en bloc resection of the huge retroperitoneal tumor after primary neoadjuvant chemotherapy, the final outcome was still poor. A diagnosis according to radiologic findings was uncharacteristic. Finally, a pathologic diagnosis based on histologic and immunohistochemical results revealed a rare renal peripheral primitive neuroectodermal tumor

    Effects of Electroacupuncture on Benign Prostate Hyperplasia Patients with Lower Urinary Tract Symptoms: A Single-Blinded, Randomized Controlled Trial

    Get PDF
    We tested the effect of electroacupuncture (EA) on lower urinary tract symptoms (LUTS) in benign prostatic hyperplasia (BPH) patients. A total of 42 BPH patients with LUTS were randomly assigned to either the EA group (EG), received 2 Hz EA for 20 min twice/week for a total of twelve treatments, or a sham EA group (CG), received sham EA. The increase of voiding volume, average flow rate, and maximal flow rate in the EG were 32.2 ± 104.4 mL, 1.2 ± 1.6 mL/sec, and 2.3 ± 3.7 mL/sec, respectively, from baseline value (before EA) using the measurement of an uroflowmetry. These increases were greater than −37.9 ± 120.4, −0.22 ± 2.7, and −0.3 ± 4.3, respectively, in the CG (P = .038, .026, and .030, resp.). The changes of prostate special antigen and international prostatic symptom score were not significantly different between two groups (P = .573, .175, resp.), suggesting the clinical improvement of 2 Hz EA was quite limited to the LUTS of patients with BPH

    Pulsed laser deposition of hexagonal GaN-on-Si(100) template for MOCVD applications

    Get PDF
    Growth of hexagonal GaN on Si(100) templates via pulsed laser deposition (PLD) was investigated for the further development of GaN-on-Si technology. The evolution of the GaN growth mechanism at various growth times was monitored by SEM and TEM, which indicated that the GaN growth mode changes gradually from island growth to layer growth as the growth time increases up to 2 hours. Moreover, the high-temperature operation (1000°C) of the PLD meant no significant GaN meltback occurred on the GaN template surface. The completed GaN templates were subjected to MOCVD treatment to regrow a GaN layer. The results of X-ray diffraction analysis and photoluminescence measurements show not only the reliability of the GaN template, but also the promise of the PLD technique for the development of GaN-on-Si technology

    Measurement of the Earth’s Rotation Using a Chip-Based Brillouin Laser Gyroscope

    Get PDF
    We report a chip-based Brillouin laser gyroscope with 0.068°/√ h angular random walk and 3.6°/h bias stability. The device can resolve sinusoidal rotations with amplitude as low as 5°/h and is also used to measure the Earth’s rotation

    Fibers and Conductive Films Using Silver Nanoparticles and Nanowires by Near-Field Electrospinning Process

    Get PDF
    The silver nanowires (AgNWs) and silver nanoparticles (AgNPs) were synthesized. With near-field electrospinning (NFES) process, fibers and thin films with AgNPs and AgNWs were fabricated. In the NFES process, 10 k voltage was applied and the AgNPs and AgNWs fibers can be directly orderly collected without breaking and bending. Then, the characteristics of the fibers were analyzed by four-point probe and EDS. The conductive film was analyzed. When the thickness of films with AgNWs and AgNPs was 1.6 µm, the sheet resistance of films was 0.032 Ω/sq which was superior to that of the commercial ITO. The transmissivity of films was analyzed. The transmissivity was inversely proportional to sheet resistance of the films. In the future, the fibers and films can be used as transparent conductive electrodes

    HuR cytoplasmic expression is associated with increased cyclin A expression and poor outcome with upper urinary tract urothelial carcinoma

    Get PDF
    BACKGROUND: HuR is an RNA-binding protein that post-transcriptionally modulates the expressions of various target genes implicated in carcinogenesis, such as CCNA2 encoding cyclin A. No prior study attempted to evaluate the significance of HuR expression in a large cohort with upper urinary tract urothelial carcinomas (UTUCs). METHODS: In total, 340 cases of primary localized UTUC without previous or concordant bladder carcinoma were selected. All of these patients received ureterectomy or radical nephroureterectomy with curative intents. Pathological slides were reviewed, and clinical findings were collected. Immunostaining for HuR and cyclin A was performed and evaluated by using H-score. The results of cytoplasmic HuR and nuclear cyclin A expressions were correlated with disease-specific survival (DSS), metastasis-free survival (MeFS), urinary bladder recurrence-free survival (UBRFS), and various clinicopathological factors. RESULTS: HuR cytoplasmic expression was significantly related to the pT status, lymph node metastasis, a higher histological grade, the pattern of invasion, vascular and perineurial invasion, and cyclin A expression (p = 0.005). Importantly, HuR cytoplasmic expression was strongly associated with a worse DSS (p < 0.0001), MeFS (p < 0.0001), and UBRFS (p = 0.0370) in the univariate analysis, and the first two results remained independently predictive of adverse outcomes (p = 0.038, relative risk [RR] = 1.996 for DSS; p = 0.027, RR = 1.880 for MeFS). Cyclin A nuclear expression was associated with a poor DSS (p = 0.0035) and MeFS (p = 0.0015) in the univariate analysis but was not prognosticatory in the multivariate analyses. High-risk patients (pT3 or pT4 with/without nodal metastasis) with high HuR cytoplasmic expression had better DSS if adjuvant chemotherapy was performed (p = 0.015). CONCLUSIONS: HuR cytoplasmic expression was correlated with adverse phenotypes and cyclin A overexpression and also independently predictive of worse DSS and MeFS, suggesting its roles in tumorigenesis or carcinogenesis and potentiality as a prognostic marker of UTUC. High HuR cytoplasmic expression might identify patients more likely to be beneficial for adjuvant chemotherapy

    Detection of Cartilage Oligomeric Matrix Protein Using a Quartz Crystal Microbalance

    Get PDF
    Current methods for diagnosing early stage osteoarthritis (OA) based on the magnetic resonance imaging and enzyme-linked immunosorbent assay methods are specific, but require specialized laboratory facilities and highly trained personal to obtain a definitive result. In this work, a user friendly and non-invasive quartz crystal microbalance (QCM) immunosensor method has been developed to detect Cartilage Oligomeric Matrix Protein (COMP) for early stage OA diagnosis. This QCM immunosensor was fabricated to immobilize COMP antibodies utilizing the self-assembled monolayer technique. The surface properties of the immunosensor were characterized by its FTIR and electrochemical impedance spectra (EIS). The feasibility study was based on urine samples obtained from 41 volunteers. Experiments were carried out in a flow system and the reproducibility of the electrodes was evaluated by the impedance measured by EIS. Its potential dynamically monitored the immunoreaction processes and could increase the efficiency and sensitivity of COMP detection in laboratory-cultured preparations and clinical samples. The frequency responses of the QCM immunosensor changed from 6 kHz when testing 50 ng/mL COMP concentration. The linear regression equation of frequency shift and COMP concentration was determined as: y = 0.0872 x + 1.2138 (R2 = 0.9957). The COMP in urine was also determined by both QCM and EIS for comparison. A highly sensitive, user friendly and cost effective analytical method for the early stage OA diagnosis has thus been successfully developed
    corecore