551 research outputs found
Classifying, clustering and clumping: defining groups of irrigators in Australia's Namoi Valley
[Extract] This paper explores the non-commercial factors influencing farmers' decision making in the context of the recently implemented Water Sharing Plans (WSP) in the Namoi Valley of New South Wales. In line with the governments water reform goals, the WSP were introduced to rectify an over allocation of groundwater resources. The required amount of entitlement reduction varied across the valley, according to the existing amount of over allocation, and has resulted in some licence holders losing up to 94% of their entitlements. To manage this degree of reduction most licence holders have to make some kind of decision about how to deal with it. This could be by purchasing or selling land or water
Recommended from our members
Steam reforming of DOE complex waste simulants
Sandia National Laboratories has worked with Synthetica Technologies and Manufacturing and Technology Conversion International (MTCl) to demonstrate the applicability of their commercial steam reforming technologies for treating DOE low-level mixed wastes. Previously, Synthetica successfully demonstrated destruction of a Sandia formulated lab trash simulant. During November 1994 Synthetica did not adequately process the aqueous halogenated organic liquid mixed waste simulant (MWTP-2110) formulated by the DOE Mixed Waste Integrated Program (MWIP). Testing at MTCl is ongoing and initial results appear to be favorable. Approximately 200 lbs each of the MWIP aqueous halogenated organic liquids (MWTP-2110), and absorbed aqueous and organic liquids (MWTP-3113/3114) simulants have been processed. At 1650{degree}F, destruction efficiencies of greater than 99% were obtained for tetrachloroethylene, toluene, and 1,2 dichlorobenzene. Product cases consisted primarily of H{sub 2}, C0{sub 2}, CO, and CH{sub 4} and had higher heating values of up to 355 BTU/SCF. Conclusions concerning the suitability of the MTCI process for treating DOE mixed wastes will be drawn upon the completion of testing
A rapid turnaround gene panel for severe autoinflammation: Genetic results within 48 hours
There is an important unmet clinical need for fast turnaround next generation sequencing (NGS) to aid genetic diagnosis of patients with acute and sometimes catastrophic inflammatory presentations. This is imperative for patients who require precise and targeted treatment to prevent irreparable organ damage or even death. Acute and severe hyper- inflammation may be caused by primary immunodeficiency (PID) with immune dysregulation, or more typical autoinflammatory diseases in the absence of obvious immunodeficiency. Infectious triggers may be present in either immunodeficiency or autoinflammation. We compiled a list of 25 genes causing monogenetic immunological diseases that are notorious for their acute first presentation with fulminant inflammation and which may be amenable to specific treatment, including hemophagocytic lymphohistiocytosis (HLH); and autoinflammatory diseases that can present with early-onset stroke or other irreversible neurological inflammatory complications. We designed and validated a pipeline that enabled return of clinically actionable results in hours rather than weeks: the Rapid Autoinflammation Panel (RAP). We demonstrated accuracy of this new pipeline, with 100% sensitivity and 100% specificity. Return of results to clinicians was achieved within 48-hours from receiving the patient's blood or saliva sample. This approach demonstrates the potential significant diagnostic impact of NGS in acute medicine to facilitate precision medicine and save "life or limb" in these critical situations
Recommended from our members
Analysis of the technical capabilities of DOE sites for disposal of residuals from the treatment of mixed low-level waste
The US Department of Energy (DOE) has stored or expects to generate over the next five years more than 130,000 m{sup 3} of mixed low-level waste (MLLW). Before disposal, MLLW is usually treated to comply with the land disposal restrictions of the Resource Conservation and Recovery Act. Depending on the type of treatment, the original volume of MLLW and the radionuclide concentrations in the waste streams may change. These changes must be taken into account in determining the necessary disposal capacity at a site. Treatment may remove the characteristic in some waste that caused it to be classified as mixed. Treatment of some waste may, by reduction of the mass, increase the concentrations of some transuranic radionuclides sufficiently so that it becomes transuranic waste. In this report, the DOE MLLW streams were analyzed to determine after-treatment volumes and radionuclide concentrations. The waste streams were reclassified as residual MLLW or low-level or transuranic waste resulting from treatment. The volume analysis indicated that about 89,000 m{sup 3} of waste will require disposal as residual MLLW. Fifteen DOE sites were then evaluated to determine their capabilities for hosting disposal facilities for some or all of the residual MLLW. Waste streams associated with about 90% of the total residual MLLW volume are likely to present no significant issues for disposal and require little additional analysis. Future studies should focus on the remaining waste streams that are potentially problematic by examining site-specific waste acceptance criteria, alternative treatment processes, alternative waste forms for disposal, and pending changes in regulatory requirements
A novel coil array for combined TMS/fMRI experiments at 3 T
PURPOSE: To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. METHODS: The state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7-channel receive-only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state-of-the-art setup. RESULTS: MR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g-factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible. CONCLUSION: The novel coil array is safe, strongly improves signal-to-noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design
- …