2 research outputs found

    The ‘AbdoMAN’: An artificial abdominal wall simulator for biomechanical studies on laparotomy closure techniques

    Get PDF
    Purpose: Incisional hernia remains a frequent complication after abdominal surgery associated with significant morbidity and high costs. Animal and clinical studies have exhibited some limitations. The purpose of this study was to develop an artificial human abdominal wall (AW) simulator in order to enable investigations on closure modalities. We hypothesized that a physical model of the human AW would give new insight into commonly used suture techniques representing a substantial complement or alternative to clinical and animal studies. Methods: The ‘AbdoMAN’ was developed to simulate human AW biomechanics. The ‘AbdoMAN’ capacities include measurement and regulation of intra-abdominal pressure (IAP), generation of IAP peaks as a result of muscle contraction and measurements of AW strain patterns analyzed with 3D image stereo correlation software. Intact synthetic samples were used to test repeatability. A laparotomy closure was then performed on five samples to analyze strain patterns. Results: The ‘AbdoMAN’ was capable of simulating physiological conditions. AbdoMAN lateral muscles contract at 660 N, leading the IAP to increase up to 74.9 mmHg (range 65.3–88.3). Two strain criteria were used to assess test repeatability. A test with laparotomy closure demonstrated closure testing repeatability. Conclusions: The ‘AbdoMAN’ reveals as a promising enabling tool for investigating AW surgery-related biomechanics and could become an alternative to animal and clinical studies. 3D image correlation analysis should bring new insights on laparotomy closure research. The next step will consist in evaluating different closure modalities on synthetic, porcine and human AW.Industrial Desig

    Clinical, mechanical, and immunohistopathological effects of tissue adhesives on the colon: An in-vivo study

    No full text
    Background: Tissue adhesives may be useful for sealing bowel anastomoses by preventing anastomotic leakage. Prior to clinical implementation, an in-depth analysis of the clinical and immunohistopathological effects of tissue adhesives on the target tissue and of the mechanical strength of the adhesive bond in an in vivo model is needed. Materials and methods: In 84 rats, two bowel segments were glued using one of the following tissue adhesive: Bioglue, Gelatin-resorcinol-formaldehyde (GRF), Glubran 2, Histoacryl Flex, Omnex, Duraseal Xact, or Tissucol. Rats were followed for 7 or 28 days. Endpoints were clinical complication rate, mechanical strength, and immunohistopathological reactions. Results: Of the seven tissue adhesives, GRF and Bioglue showed the highest rates of bowel wall destruction and ileus and the most severe immunohistopathological tissue reactions at 7 and 28 days. Cyanoacrylates (Histoacryl Flex, Omnex, Glubran 2) showed high mechanical strength and mild immunohistopathological reactions at 7 and 28 days. Duraseal Xact and Tissucol were the most inert tissue adhesives, but exhibited low mechanical strength. At 28 days, mechanical strength was significantly correlated to CD8, CD68, and Ki67 cell counts. Conclusion: Based on the clinical and immunohistopathological outcomes, GRF and Bioglue were found to be the least suitable tissue adhesives for colonic use. Duraseal Xact and Tissucol were inert but also showed low mechanical strength. Cyanoacrylates exhibited mild clinical and immunohistopathological effects while maintaining high strength, which makes them promising as colonic sealants.Accepted Author ManuscriptMedical Instruments & Bio-Inspired Technolog
    corecore