29 research outputs found

    Plasma midregional proadrenomedullin (MR-proADM) concentrations and their biological determinants in a reference population

    Get PDF
    Background: Midregional proadrenomedullin (MR-proADM) is emerging as a prognostic biomarker for detecting the failure of multiple organs. Establishment of scientifically robust reference intervals facilitates interpretation of laboratory test results. The objectives of this study were (i) to establish reliable reference intervals for plasma MR-proADM using a commercially available automated fluoroimmunoassay in apparently healthy individuals, and (ii) to identify biological determinants of MR-proADM concentrations. Methods: A total of 506 questionnaire-identified apparently healthy adults were enrolled in a single-center, cross-sectional study. A final reference group (n = 172) was selected after exclusion of obese individuals, those with increased values of laboratory biomarkers indicating asymptomatic myocardial injury or dysfunction, ongoing inflammation, diabetes, dyslipidemia and renal dysfunction and outliers. Results: The 2.5th and 97.5th percentile intervals for MR-proADM values in the reference group (90% confidence interval) were 0.21 (0.19-0.23) and 0.57 (0.55-0.59) nmol/L, respectively. Although older age, higher values of HbA(1c), C-reactive protein, B-type natriuretic peptide and body mass index, together with a history of smoking and a decreased estimated glomerular filtration rate were significantly associated with increasing concentrations of MR-proADM in both univariate and multivariate analyses, magnitudes of these relationships were modest and did not substantially influence MR-proADM reference intervals. Sex-dependent difference in MR-proADM reference intervals was not detected [0.19 (0.16-0.22)-0.56 (0.54-0.60) nmol/L in females vs. 0.22 (0.20-0.25)-0.58 (0.57-0.63) nmol/L in males]. Conclusions: Our study successfully established robust reference intervals for MR-proADM concentrations in plasma. Considering the negligible influence of potential biological determinants on plasma MR-proADM, we recommend the adoption of single reference intervals for adult population as a whole

    Traceability validation of six enzyme measurements on the Abbott Alinity c analytical system

    Get PDF
    Background: Laboratory professionals should independently verify the correct implementation of metrological traceability of commercial measuring systems and determine if their performance is fit for purpose. We evaluated the trueness, uncertainty of measurements, and transferability of six clinically important enzyme measurements (alanine aminotransferase [ALT], alkaline phosphatase [ALP], aspartate aminotransferase [AST], creatine kinase [CK], \u3b3-glutamyltransferase [\u3b3GT], and lactate dehydrogenase [LDH]) performed on the Abbott Alinity c analytical system. Methods: Target values and associated uncertainties were assigned to three pools for each enzyme by using the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference measurement procedures (RMPs) and the pools were then measured on the Alinity system. Bias estimation and regression studies were performed, and the uncertainty associated with Alinity measurements was also estimated, using analytical performance specifications (APS) derived from biological variability of measurands as goals. Finally, to validate the transferability of the obtained results, a comparison study between two Alinity systems located in Milan, Italy, and Bydgoszcz, Poland, was carried out. Results: Correct implementation of traceability to the IFCC RMPs and acceptable measurement uncertainty fulfilling desirable (ALP, AST, LDH) or optimal APS (ALT, CK, \u3b3GT) was verified for all evaluated enzymes. An optimal alignment between the two Alinity systems located in Milan and Bydgoszcz was also found for all enzyme measurements. Conclusions: We confirmed that measurements of ALT, ALP, AST, CK, \u3b3GT, and LDH performed on the Alinity c analytical system are correctly standardized to the IFCC reference measurement systems and the system alignment is consistent between different platforms

    Laboratory-related issues in the measurement of cardiac troponins with highly sensitive assays

    No full text
    A number of assay-related issues can affect the performance of cardiac troponin (cTn) measurement in everyday practice. In this respect, it is vital that all information on cTn assays is known and that the performance characteristics of assays are objectively assessed and adequately described. The advent of the latest generation of more sensitive cTn assays has heralded a new wave of information about low concentrations of cTn in blood. These recent generation assays have improved analytical sensitivity and corresponding performance at low cTn concentrations when compared to their predecessors, providing a convincing goal for laboratory medicine in helping clinicians in the diagnosis of acute myocardial infarction. Crucial to the clinical utility of highly sensitive cTn assays is the laboratorians\u2019 role in closely scrutinizing proposed assays and defining their value in relation to available evidence. Analytical, as well as pre-analytical and post-analytical, aspects must be documented. In this review, we describe what laboratory professionals should know about their cTn assay performance characteristics and the pre-analytical prerequisites for robustness to ensure optimal post-analytical reporting

    0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction

    No full text

    Establishing reference intervals for galectin-3 concentrations in serum requires careful consideration of its biological determinants

    No full text
    Background: Appropriately established reference intervals for laboratory biomarkers may help the interpretation of their results and facilitate clinical utilization. Objectives: i) To determine reference intervals for serum galectin-3 measured using the Architect STAT immunoassay, and ii) to identify factors affecting galectin-3 concentrations. Methods: We recruited 533 questionnaire-identified apparently healthy individuals, in which laboratory biomarkers were used to detect asymptomatic myocardial injury and dysfunction, ongoing inflammation, hyperglycemia, dyslipidemia, and renal dysfunction. A final reference group of 180 subjects was selected. Results: 2.5th and 97.5th percentiles of distribution of galectin-3 concentrations in the reference group (90% confidence interval) were 5.9 (5.0\u20136.8) and 18.1 (17.2\u201319.0) \u3bcg/L, respectively. Older age contributed to higher galectin-3 concentrations, but influenced derived reference intervals to a lesser extent. Other major determinants of galectin-3 concentrations observed in the questionnaire-screened population were not linked to galectin-3 in reference individuals. In aiming to decide if reference limits should be partitioned by age, we compared galectin-3 concentrations in subjects < 40 (n = 124) and 6540 years (n = 56). Higher galectin-3 concentrations were found in older people (median, 12.4 \u3bcg/L vs. 11.5 \u3bcg/L, p = 0.016). Accounting for manufacturer's declared imprecision at galectin-3 physiological concentrations of < 10% (as CV) and the estimated URL for subjects 6540 (18.8 \u3bcg/L) and < 40 (17.9 \u3bcg/L), we recommend the adoption of a single URL for the overall adult population. Conclusions: We established reference intervals for galectin-3 in which the effects of biological determinants were irrelevant. Although in healthy subjects age may affect galectin-3 release, this does not appear to necessitate age-related reference limits

    A study of biological and lifestyle factors, including within-subject variation, affecting concentrations of growth differentiation factor 15 in serum

    No full text
    Background Growth differentiation factor 15 (GDF-15) is an emerging cardiovascular biomarker, and a fully automated immunoassay has recently become available. The objectives of the study were to identify biological and lifestyle factors affecting serum GDF-15 concentrations and derive robust reference intervals, and to estimate GDF-15 within-subject biological variation and derived indices. Methods A presumably healthy population of 533 questionnaire-screened adults was used to identify the biological and lifestyle determinants of serum GDF-15. Following stringent exclusion criteria, a final group of 173 individuals was selected to establish GDF-15 reference interval. Twenty-six healthy volunteers were enrolled in the biological variation substudy. Results Using a multiple regression model, age, B-type natriuretic peptide and C-reactive protein as well as smoking status were significantly related to serum GDF-15 concentrations. The upper reference limit (URL) for serum GDF-15 concentrations (90% confidence interval [CI]) was 866 ng/L (733\u2013999 ng/L), with no sex-related difference. Although GDF-15 tended to increase with age, the weak dependence of marker from age does not justify age-related URL. The within-subject CV was 6.3% (95% CI, 4.5%\u20138.5%), with no sex difference in intraindividual variances. The reference change value (RCV) for GDF-15 was 23%, and two are the specimens required to ensure that the mean GDF-15 result is within \ub110% of the individual\u2019s homeostatic set point. Conclusions By identifying the main factors influencing serum GDF-15 concentrations, we robustly established the URL to be applied in adult population. As intraindividual variation of GDF-15 is relatively low, monitoring longitudinal changes in its concentrations over time using RCV can be a good alternative for interpreting GDF-15 in clinical setting
    corecore