22 research outputs found

    Intravascular MR-monitored balloon angioplasty: An in vivo feasibility study

    Get PDF
    PURPOSE: To develop a new method for monitoring balloon angioplasty by using an intravascular magnetic resonance (MR) imaging technique. MATERIALS AND METHODS: Nine New Zealand White rabbits were used: seven for technique refinement, including surgery, device insertion, stenosis creation, and MR protocol development; and two for the final MR imaging of the balloon angioplasty. The in vivo experimental method involved insertion of a catheter antenna and a balloon catheter, via femoral arteriotomies bilaterally, into the target site of the upper abdominal aorta, where a stenosis was artificially created by binding a plastic cable tie. Then, the entire process of the dilation of the stenosis with balloon inflation was monitored under MR fluoroscopy. RESULTS: Catheter insertions were successful, and a 5-mm-long stenosis of the aorta was produced in all nine rabbits. Eight complete balloon angioplasty procedures were satisfactorily monitored and recorded, showing clearly the stenosis of the aorta at the beginning of the procedure, the dilation of the stenosis during the balloon inflation, and the complete opening of the stenosis after balloon dilation. CONCLUSION: Preliminary results of in vivo balloon angioplasty monitored with intravascular MR imaging are presented. MR fluoroscopy, based on the intravascular MR imaging technique, may represent a potential alternative to x-ray fluoroscopy for guiding interventional treatment of cardiovascular diseases

    In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction

    Get PDF
    Background - We investigated the potential of magnetic resonance imaging (MRI) to track magnetically labeled mesenchymal stem cells (MR-MSCs) in a swine myocardial infarction (MI) model. Methods and Results - Adult farm pigs (n=5) were subjected to closed-chest experimental MI. MR-MSCs (2.8 to 16×107 cells) were injected intramyocardially under x-ray fluoroscopy. MRIs were obtained on a 1.5T MR scanner to demonstrate the location of the MR-MSCs and were correlated with histology. Contrast-enhanced MRI demonstrated successful injection in the infarct and serial MSC tracking was demonstrated in two animals. Conclusion - MRI tracking of MSCs is feasible and represents a preferred method for studying the engraftment of MSCs in MI

    MR-trackable intramyocardial injection catheter

    Get PDF
    There is growing interest in delivering cellular agents to infarcted myocardium to prevent postinfarction left ventricular remodeling. MRI can be effectively used to differentiate infarcted from healthy myocardium. MR-guided delivery of cellular agents/therapeutics is appealing because the therapeutics can be precisely targeted to the desired location within the infarct. In this study, a steerable intramyocardial injection catheter that can be actively tracked under MRI was developed and tested. The components of the catheter were arranged to form a loopless RF antenna receiver coil that enabled active tracking. Feasibility studies were performed in canine and porcine myocardial infarction models. Myocardial delayed-enhancement (MDE) imaging identified the infarcted myocardium, and real-time MRI was used to guide left ventricular catheterization from a carotid artery approach. The distal 35 cm of the catheter was seen under MRI with a bright signal at the distal tip of the catheter. The catheter was steered into position, the distal tip was apposed against the infarct, the needle was advanced, and a bolus of MR contrast agent and tissue marker dye was injected intramyocardially, as confirmed by imaging and post-mortem histology. A pilot study involving intramyocardial delivery of magnetically labeled stem cells demonstrated the utility of the active injection catheter system. © 2004 Wiley-Liss, Inc

    Hind limb ischemia in rabbit model: T2-prepared versus time-of-flight MR angiography at 3 T.

    No full text
    PURPOSE: To prospectively compare various parameters of vessels imaged at 3 T by using time-of-flight (TOF) and T2-prepared magnetic resonance (MR) angiography in a rabbit model of hind limb ischemia. MATERIALS AND METHODS: Experiments were approved by the institutional animal care and use committee. Endovascular occlusion of the left superficial femoral artery was induced in 14 New Zealand white rabbits. After 2 weeks, MR angiography and conventional (x-ray) angiography were performed. Vessel sharpness was evaluated visually in the ischemic and nonischemic limbs, and the presence of small collateral vessels was evaluated in the ischemic limbs. Vessel sharpness was also quantified by evaluating the magnitude of signal intensity change at the vessel borders. RESULTS: The sharpness of vessels in the nonischemic limbs was similar between the TOF and the T2-prepared images. In the ischemic limbs, however, T2-prepared imaging, as compared with TOF imaging, generated higher vessel sharpness in arteries with diminished blood flow (mean vessel sharpness: 44% vs 30% for popliteal arteries, 45% vs 28% for saphenous arteries; P < .001 for both comparisons) and enabled better detection of small collateral vessels (93% vs 36% of vessels, P < .001). CONCLUSION: T2-prepared imaging can facilitate high-spatial-resolution MR angiography of small vessels with low blood flow and thus has potential as a tool for noninvasive evaluation of arteriogenic therapies, without use of contrast material. Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2452062067/DC1

    Stimulated-echo acquisition mode (STEAM) MRI for black-blood delayed hyperenhanced myocardial imaging.

    No full text
    PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size

    Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON)

    No full text
    In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ability to illuminate these structures with positive contrast would enhance noninvasive MR tracking of cellular therapeutics. Therefore, an MRI methodology that selectively highlights areas of metallic objects has been developed. Inversion-recovery with ON-resonant water suppression (IRON) employs inversion of the magnetization in conjunction with a spectrally-selective on-resonant saturation prepulse. If imaging is performed after these prepulses, positive signal is obtained from off-resonant protons in close proximity to the metallic objects. The first successful use of IRON to produce positive contrast in areas of metallic spheres and SPIO-labeled stem cells in vitro and in vivo is presented
    corecore