29 research outputs found

    Definition of a composite index of glazing rooms

    Get PDF
    The effect of geometrical parameters of rooms and window openings on the value of the daylight factor (DF) in the reference point on the work surface is considered in the article. This is important, as while using a light factor (LF) and a window-to-wall ratio (WWR), there is a significant error. Therefore, there are objective difficulties with the unification of the results of studies on the effectiveness of natural sidelight, which are due to the influence of the size of the room on the DF value in the reference point on the work surface. The use of the above-mentioned coefficients to evaluate the efficiency of lateral natural light results in the fact that, at constant value of the coefficient, the value of the DF may differ several times. This is because the area of the window opening does not correspond to the area of glazing through which daylight passes into the room. The area of the room does not correspond to the area of the work surface on which it is necessary to provide normalized illumination, and the dimensions of both the room and the work surface are not taken into account in the LF or in the WWR at all. It is proposed to use a composite room glazing index (CRGI). It takes into account not only the glazing area of the window opening but also the dimensions and area of the work surface. This makes it possible to use the results of studies on the effectiveness of natural light without binding them to the dimensions of a room. Using the Relux program, the DF value in the reference point for rooms of different sizes with different glazing areas of the window openings is calculated and the dependence of the DF on the CRGI has been obtained. As a result of the approximation of this dependence, an equation describing the relationship between these quantities has been developed. An algorithm that takes into account both the width of the opaque portion of the window opening and its proportion has been developed to determine the area of the window opening at which the required value of the DF in the reference point is provided. The obtained scientific result in the forms of the CRGI and algorithm of calculating the area of the window opening is interesting from the theoretical point of view. From a practical point of view, the results help calculate the minimum glazing area of the window opening to provide a normalized DF value with a standard deviation of 0.894, based solely on the dimensions of the room. This is a prerequisite for using the obtained results in the development of normative documents for construction sitesРозглянуто вплив геометричних параметрів приміщень та віконних прорізів на величину коефіцієнта природного освітлення (КПО) в розрахунковій точці на робочій поверхні. Це важливо, тому що при використанні window-to-floor ratio та window-to-wall ratio спостерігається значна похибка. Тому існують об’єктивні труднощі з уніфікацією результатів досліджень ефективності бокового природного освітлення, які обумовлені впливом розмірів приміщення на значення КПО в розрахунковій точці на робочій поверхні. Використання вищезгаданих коефіцієнтів для оцінки ефективності бокового природного освітлення призводить до того, що при сталому значення коефіцієнта, величина КПО може відрізнятися в декілька раз. Це зумовлено тим, що площа віконного прорізу не відповідає площі засклення, через яке денне світло проходить в середину приміщення. Площа приміщення не відповідає площі робочої поверхні, на якій потрібно забезпечити нормовану освітленість, а розміри як приміщення, так і робочої поверхні, взагалі не враховуються ні в WWR, ні в WFR. Запропоновано використовувати зведений індекс засклення приміщення (ЗІЗП). Він враховує не тільки площу засклення віконного прорізу, але й розміри та площу робочої поверхні. Це дає можливість використовувати результати досліджень ефективності природного освітлення без прив’язки до конкретних розмірів приміщення. За допомогою програми Relux розраховано значення КПО в розрахунковій точці для приміщень різних розмірів з різною площею засклення віконного прорізу і отримано залежність КПО від ЗІЗП. В результаті апроксимації даної залежності отримано рівняння, яке описує взаємозв’язок між даними величинами. Для визначення площі віконного прорізу, при якій буде забезпечено необхідне значення КПО в розрахунковій точці, розроблено алгоритм, який враховує як ширину непрозорої частини віконного прорізу, так і його пропорції. Отриманий науковий результат у вигляді ЗІЗП та алгоритму розрахунку площі віконного прорізу є цікавим з теоретичної точки зору. З практичної точки зору отримані результати дозволяють розраховувати мінімальну площу засклення віконного прорізу для забезпечення нормованого значення КПО з стандартним відхиленням 0,894, спираючись виключно на розміри приміщення. Це складає передумови для використання отриманих результатів при розробці будівельних нормативних документі

    The relationship of melatonin concentration in preterm infants and adverse outcomes in the late neonatal period

    Get PDF
    IntroductionThe aim of research was to assess the melatonin concentrations in the early neonatal period as a predictor of adverse outcomes of late neonatal period in preterm infants and to estimate its optimal predictive cut-off values. Materials and methodsA total of 115 preterm infants admitted to the neonatal intensive care unit were screened for eligibility, five did not meet the criteria, six parents declined the participation. So, a total of 104 preterm infants with gestational age 25-34 weeks were included in research. The concentration of melatonin in urine was determined by the Enzyme Immunoassay method (Human Melatonin Sulfate ELISA kit, Elabscience, China). The Mann-Whitney U-test and analysis of the receiver operating characteristic (ROC) curve were used in statistical analysis. ResultsAnalysis of the ROC curves has revealed optimal cut-off values for urinary melatonin concentration to predict late outcomes. Melatonin concentration below 3.58 ng/ml with sensitivity of 72% can predict development of retinopathy of prematurity (ROP) (AUC = 0.73; 95% confidence intervals (CI) 0.61-0.86). Good diagnostic accuracy (AUC = 0.80; 95% CI 0.67-0.93) has been shown for bronchopulmonary dysplasia (BPD). The optimal cut-off value for melatonin concentration in BPD prediction is 3.71 ng/ml (sensitivity 80%, specificity 64%). Urinary melatonin concentration below 3.79 ng/ml can be associated with late-onset sepsis (AUC = 0.76; 95% CI 0.64-0.87; sensitivity 72%; specificity 62%). There were no significant associations between melatonin concentration and necrotizing enterocolitis (P = 0.912). ConclusionUrinary melatonin concentration below the certain cut-off values in the early neonatal period may serve as one of the predictors of adverse outcomes such as BPD, ROP, and late-onset sepsis in the late neonatal period in preterm infants

    Analysis of heat supply systems for residential buildings

    Get PDF
    Проаналізовано досвід експлуатації систем теплопостачання, подано їх переваги та недоліки, запропоновано перехід до децентралізованого теплопостачання.The experience of operation of heat supply systems is analyzed, their advantages and disadvantages are presented, the transition to decentralized heat supply is proposed

    Економічна та енергетична ефективність систем керування штучним освітленням сходів багатоповерхових житлових будинків

    Get PDF
    Метою даного дослідження є визначення економічної та енергетичної ефективності використання систем керування штучним освітленням за допомогою астрономічного реле та датчиків руху з різними типами джерел світла для сходів (майданчиків та маршів) багатоповерхових житлових будинків. Для цього було проведено аналіз помісячної інтенсивності руху мешканців 9-ти поверхових житлових будинків через дверні прорізи вхідних і квартирних дверей будинку. Визначено економічну та енергетичну ефективність використання систем керування штучним освітленням за допомогою астрономічного реле та датчиків руху з різними типами джерел світла. Встановлено, що незалежно від енергоефективності джерел світла використання астрономічного реле призводить до зниження споживання електроенергії на штучне освітлення на 49,31 – 50,58%. В той час, як використання датчиків руху призводить до більш суттєвого зменшення споживання електроенергії, а саме: при використанні ламп розжарення – на 97,92%, галогенних ламп – на 97,73%, компактних люмінесцентних ламп – на 95,27%, світлодіодних ламп – на 93,98%. Уперше отримані дані інтенсивності руху мешканців 9-ти поверхових житлових будинків через дверний проріз першого поверху для м. Тернопіль. Доведено економічну доцільність та енергоефективність використання суміщеного освітлення (природного і штучного) з системою керування штучним освітленням для сходів (маршів і майданчиків) багатоповерхових житлових будинківThe aim of the research is to determine the economic and energy efficiency usage of the artificial lighting control systems, with the help of astronomical relays and motion sensors, by various types of light sources for the stairwells (stair landings and staircases) of multistory residential buildings. The analysis of the residents’ monthly movement intensity of the 9-story residential buildings through the buildings entrance, doorways, and apartment doors was carried out. The economic and energy efficiency of use the artificial lighting control systems with an astronomical relays and motion sensors with different types of light sources was determined. Regardless of the light sources` type, the astronomical relay’s use leads to reduction in the electricity consumption of artificial lighting in 43.31% – 50.52%. Moreover, the motion sensors’ use on stairwells leads to a significant reduction in electrical energy consumption: in a case of halogen lamps – by 97.73%, compact fluorescent lamps – by 95.27%, light-emitting diodes lamps – by 93.98%. For the first time, the data of 9-story residential buildings inhabitants’ traffic intensity through the first-floor doorway for the Ternopil city, Ukraine has been carried out. It has been proved the economic feasibility and energy efficiency of using combined lighting with an artificial lighting control system for stairwells of multistory residential buildings

    Ways to save fuel and energy resources in daily graft

    Get PDF
    Дослідним шляхом встановлено вплив різних типів джерел теплової енергії (газової плити на 4 конфорки, індукційної плити та електрочайника), об’ємів води, діаметра конфорок газової плити (55 мм, 75 мм, 100 мм), діаметра ємностей для нагрівання води до закипання на енергоощадність приготування їжі в побутових умовах. Доведено, що: а) найкращим приладом для приготування їжі в домашніх умовах є індукційна плита; б) зростання коефіцієнта корисної дії при нагріванні води до закипання на газовій плиті спостерігається в напрямку збільшення співвідношення діаметра каструлі до діаметра конфорки газової плити; в) для всіх джерел теплової енергії характерним є те, що при зростанні об’ємів води зростає й коефіцієнт корисної дії процесу її нагрівання до закипанняThrough experience it has been set the influence of various types of heat sources (gas stove for 4 burners, induction cooktop and electric kettle), volumes of water, the diameter of gas stove burners (55 mm, 75 mm, 100 mm), the diameter of tanks for water heating till boiling on energy-saving for cooking in household conditions. It has been proved that: a) the best device for cooking in house conditions is the induction cooker; b) in case of water heating till boiling, on gas stove, there has been observed an increasing of efficiency factor. This happens in the direction of increasing the ratio of the pot diameter to the burner diameter; c) for all heat energy sources is typical that with increasing the volumes of water is increasing the efficiency factor of its heating till boiling process

    Subklinički hopotireoidizam doprinosi makrovaskularnim komplikacijama u bolesnika s dijabetes melitusom tip 2

    Get PDF
    This study aimed to evaluate changes of the lipid panel data in patients with comorbid type 2 diabetes mellitus (T2DM) and subclinical hypothyroidism (SCH) and to identify the probable prognostic values of the lipid profile for macrovascular complication (MVC) development. The study included 370 patients presented with only T2DM and 30 patients suffering from both T2DM and SCH. Receiver operating characteristic (ROC) analysis was used to identify prognostically significant values of the lipid profile with the optimal ratio of sensitivity and specificity for MVC development. All lipid profile values in the patients with T2DM combined with SCH were significantly higher compared to those with only T2DM. At the same time, SCH + T2DM increased the risk of exceeding target levels of triglycerides by 2.9 times and HDL-C by 4.1 times. Analysis of lipid profile values according to macrovascular involvement showed that total cholesterol, LDL-C and non-HDL-C in patients with T2DM and SCH were significantly higher compared to those with only T2DM. The levels of triglycerides >1.65 mmol/L, non-HDL-C >3.74 mmol/L and remnant cholesterol >0.74 mmol/L determined by the ROC analysis can be used for stratification of patients with T2DM combined with SCH into the category of increased risk of MVC development.Cilj istraživanja bio je procijeniti promjene u lipidnom profilu kod bolesnika s dijabetes melitusom tip 2 (T2DM) i subkliničkim hipotireoidizmom (SCH) te utvrditi vjerojatne prognostičke vrijednosti lipidnog profila za razvoj makrovaskularnih komplikacija (MVK). U studiju je bilo uključeno 370 bolesnika koji su imali samo T2DM i 30 bolesnika koji su imali i T2DM i SCH. Prognostički značajne vrijednosti lipidnog profila s optimalnim omjerom osjetljivosti i specifičnosti za razvoj MVK utvrđene su analizom krivulje ROC. Sve vrijednosti lipidnog profila bile su značajno više u bolesnika s T2DM u kombinaciji sa SCH u usporedbi s bolesnicima koji su imali samo T2DM. Istodobna prisutnost SCH i T2DM povećala je rizik od prekoračenja ciljnih razina triglicerida 2,9 puta i HDL kolesterola 4,1 puta. Analiza vrijednosti lipidnog profila u odnosu na zahvaćenost makrovaskularnih struktura pokazala je da su ukupni kolesterol, LDL kolesterol i ne-HDL kolesterol značajno viši u bolesnika s T2DM i SCH u usporedbi s onima koji imaju samo T2DM. Razine triglicerida >1,65 mmol/L, ne-HDL kolesterola >3,74 mmol/L i ostatnog kolesterola >0,74 mmol/L utvrđene analizom ROC mogu poslužiti za prepoznavanje bolesnika s T2DM i SCH kao skupine s povišenim rizikom za razvoj MVK

    Важливість впровадження практики енергетичного менеджменту в смарт містах

    Get PDF
    Проаналізовано сучасні методи та програми впровадження енергетичного менеджмену в різного типу міст та смарт міст.It has been analyzed modern methods and programs of energy management implementation in different types of cities and smart cities

    Energy efficiency of solar power plants in Ukraine

    Get PDF
    Досліджено енергетичну ефективність сонячних електростанцій в умовах України. Проведено відповідні розрахунки та побудовано графічні залежності.There has been researched the energy efficiency of solar power plants in the conditions of Ukraine. It has been calculated energy efficiency of solar power stations and constructed corresponding graphic dependences

    Системи розумного вуличного освітлення в сучасному місті

    Get PDF
    Освітлення вулиць та громадських приміщень є ключовим завданням місцевих і муніципальних органів влади. Розумне вуличне освітлення вночі в сучасному місті має важливе значення для безпеки дорожнього руху, особистої безпеки та міської атмосфери, а ще це запобігає злочинності та забезпечує безпеку приватної власності. Добре освітлені вулиці також покращують економічні можливості, збільшуючи години комерційної діяльності після темноти.Street and public area lighting is a key service provided by local and municipal governments. Good smart street lighting at night in a modern city is essential for road safety, personal safety, and urban ambience, and it indirectly prevents crime and provides security of properties. Well-lit streets also boost economic opportunities by expanding the hours of commercial activity after dark

    Impact of the translucent structures of exterior wall envelope orientation on the energy balance of the premises

    Get PDF
    Найпоширенішим способом введення сонячного світла в приміщення є використання системи бокового освітлення. Тому дослідження параметрів, які впливають на ефективність бокового природного освітлення, особливо на фоні тотального використання сучасних енергоефективних вікон, не втратили своєї актуальності. Дана стаття присвячена питанню впливу орієнтації, термічного опору та коефіцієнта відносного проникнення сонячної радіації (КВПСР) віконного прорізу (ВП) на сумарні втрати тепла в опалювальний період та його надходження в охолоджувальний період. Це важливо, тому що на даний час немає рекомендацій щодо значення параметрів СЗОК, за яких досягатиметься максимальна енергоефективністсть. На сьогодні основним параметром, за яким обирають металопластикові віконні конструкції, є її термічний опір. Значенням КВПСР зазвичай нехтують. Дане дослідження спрямоване на визначення впливу як термічного опору і КВПСР на витрати електроенергії для компенсації тепловтрат та теплонадходжень через СЗОК. У результаті досліджень отримано залежності витрат електроенергії на опалення та охолодження офісного приміщення від КВПСР термічного опору при зміні орієнтації СЗОК для м. Тернопіль. Це дало можливість визначити вплив орієнтації СЗОК на теплонадходження та тепловтрати приміщення за різних параметрів СЗОК. Доведено, що за рік найменше електроенергії затрачається для видалення тепла та компенсації тепловтрат через СЗОК при південній його орієнтації (при термічному опору ≤0,4), в той час, як при термічному опорі >0,4 – при північній орієнтації. Що дає можливість стверджувати, що західна та східна орієнтації СЗОК є найменш доцільними з точки зору енергоефективності. Отримані результати дозволяють у подальшому провести визначення параметрів СЗОК, за яких досягатиметься економія електроенергії з урахуванням зменшення її споживання на штучне освітлення.This article is devoted to the question of the influence of orientation, thermal resistance, and the coefficient of relative penetration of solar radiation (CRPSR) of the translucent structures of exterior wall envelope (TSEWE) on total heat loss during the heating period and its inflow in the cooling period. The aim of this study directed to determine the effect of both thermal resistance and CRPSR on the electricity consumption to compensate for heat losses and heat revenues through the TSEWE. As a result of research received the dependence of electricity consumption on the heating and cooling of the office space, from the CRPSR, the thermal resistance for different orientation of the TSEWE for the city of Ternopil. This made it possible to determine the influence of the orientation of the TSEWE on the heat input and heat loss of the premises with different parameters of the TSEWE. It is proved that during the year, the least amount of electric energy is spent to remove heat and compensate heat loss through the TSEWE, with its southern orientation (with thermal resistance ≤0.4 (m2×°C)/W), while at a thermal resistance> 0,4 (m2×°C)/W – at the northern
    corecore