23 research outputs found

    Clinically occult metastases in patients with cutaneous melanoma. Detection with sentinel lymph node biopsy and whole body positron emission tomography

    Get PDF
    Objective: The aim of this study was to investigate the use of sentinel lymph node biopsy (SLNB) and whole body positron emission tomography (PET), with emphasis on surgical treatment and prognosis, in the detection of clinically occult metastases in patients with clinically localized cutaneous melanoma. Patients and methods: The study population consisted of 1255 patients with clinical stage I–II cutaneous melanoma, operated at Turku University Hospital between 1983 and 2007. 334 patients underwent SLNB and they were compared to 921 retrospective patients. A subgroup of 30 symptom-free patients with high risk melanoma underwent prospectively whole body PET 6–24 months postoperatively. Results: Overall, the disease-specific survival rate was 84.4 % at five years. Sex, Breslow thickness, age and nodal status were independent prognostic factors for survival. SLNB revealed occult nodal metastases in 17 % of the patients. There was no significant difference in disease-specific overall survival between SLNB patients and controls, but the nodal disease-free time was significantly longer suggesting better local control after SLNB and subsequent completion lymph node dissection. The followup time was different between the study cohorts and initial surgery was performed during different time periods. SLNB detected micrometastases in seven of 155 patients (4.5 %) with thin T1 primary melanoma and in four of 25 patients (16 %) with head and neck melanoma. In six of 30 asymptomatic patients with high risk melanoma (20 %), whole body PET detected occult distant metastases. Conclusion: Both SLNB and whole body PET were reliable methods to detect clinically occult metastases in patients with cutaneous melanoma. This upstaging altered the treatment in each case.Siirretty Doriast

    Same-day mastectomy and axillary lymph node dissection is safe for most patients with breast cancer

    Get PDF
    Background and Objective The aim of this study was to evaluate the safety of same-day mastectomy, with or without a sentinel node biopsy (SNB) and/or axillary lymph node dissection (ALND). Methods In this retrospective study, we reviewed 913 consecutive women who underwent a simple mastectomy for breast cancer between the years 2014 and 2019 and were treated either with same-day surgery (SDS) or an overnight stay (OS) regime. We reviewed all surgical complications, any unplanned return to care (RTC) and the rehospitalization rate for 30 postoperative days. Results A total of 259 patients (28%) were treated with SDS and 654 patients (72%) with an OS regime. There was no difference in RTC (odds ratio: 0.79 [95% confidence interval: 0.53-1.18], p = 0.26) or any major complications between the groups. None of the investigated subgroups, such as patients with previous neoadjuvant therapy, diabetes, obesity (up to a body mass index of 40 kg/m(2)), the American Society of Anaesthesiologist Class of 3, or elderly patients aged 75-84 years, showed an increased complication rate when treated with the SDS regime. Conclusion A same-day simple mastectomy is safe with SNB and/or ALND. It can be performed safely for most patients with stable co-morbidities.Peer reviewe

    Oncological Safety of Skin-Sparing Mastectomy and Immediate Breast Reconstruction in Extensive Ductal Carcinoma In Situ

    Get PDF
    Introduction: Skin-sparing mastectomy (SSM) with immediate breast reconstruction is the ideal treatment for interested and suitable patients with extensive ductal carcinoma in situ (DCIS). There is no guideline to indicate on how large DCIS the procedure can be performed safely. The primary target of this study was to define the oncological safety of SSM in extensive pure DCIS. The secondary target was to find predictive factors for DCIS upstaging to invasive disease.Materials and methods: A total of 71 consecutive patients with extensive pure DCIS and undergoing SSM with immediate latissimus dorsi (LD) breast reconstruction were retrospectively evaluated. Results: The median size of DCIS lesion in preoperative imaging was 60 mm, the median weight of mastectomy specimen was 350 g, and the median resection margin (RM) was 2.0 mm. A total of 20 patients (28%) had an RM less than 0.5 mm and nine patients (13%) had ink positive margins. Six patients having positive RM underwent reoperation. A total of 29 patients (41%) presented invasive cancer foci in final histopathological assessment and nine patients (13%) had an axillary metastasis. Adjuvant therapy was given to 23 patients presenting invasive cancer. There were no local recurrences or distant metastases (0%, 95% confidence interval 0-0.051) during the mean follow-up of 71 mo. None of the factors evaluated predicted upstaging to invasive disease.Conclusions: SSM with immediate breast reconstruction in patients with extensive DCIS is oncologically safe even when the margins are close or positive. Additional invasive foci and solitary axillary lymph node metastases are frequent but do not worsen the outcome. (c) 2022 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Peer reviewe

    Preoperative antibiotic prophylaxis in mastectomy: A retrospective comparative analysis of 1413 patients with breast cancer

    Get PDF
    Background and objective: The reported rate of surgical site infections (SSIs) in breast cancer surgery varies widely in previous literature. The use of antibiotic prophylaxis is controversial but recommended by several guidelines. The aim of this study was to evaluate the efficacy of routine antibiotic prophylaxis in patients with breast cancer undergoing mastectomy.Methods: In this retrospective single-institution study, we reviewed 1413 consecutive female breast cancer patients who underwent mastectomy and/or axillary lymph node surgery between years 2012 and 2019. Prophylactic antibiotics for all patients undergoing mastectomy was introduced in our hospital in 2016 and before that the prophylaxis was prescribed individually on surgeons' preference. All patient records for 30 postoperative days were evaluated in detail and all SSIs were recorded. The rate of SSIs was compared between patients who received antibiotic prophylaxis and those who did not. A multivariate logistic regression model was used to define the odds ratio (OR) for the efficacy of antibiotic prophylaxis.Results: A total of 335 patients underwent mastectomy without antibiotic prophylaxis and 1078 with prophylaxis. The rate of SSIs was 6.9% in patients who received prophylaxis and 6.3% in patients without prophylaxis (p = 0.70). The rate of SSIs was similar before and after the introduction of regular antibiotic prophylaxis and there was no difference in any of the patient subgroups investigated. In multivariable logistic regression analysis, the OR for antibiotic prophylaxis was 1.04 (95% CI: 0.62-1.73, p = 0.88).Conclusions: Routine use of antibiotic prophylaxis did not reduce the rate of SSIs in mastectomy. Unselective antibiotic prophylaxis for all patients does not seem mandatory in mastectomy.</p

    Primaarimelanooman leikkaushoito

    Get PDF
    Teema: Ihomelanooma. English summar

    Ultrasonic scissors decrease postoperative bleeding complications in mastectomy : A retrospective multicenter cohort study on 728 patients

    Get PDF
    Introduction: The aim of this study was to evaluate the rate of postoperative bleeding complications (primary outcome) and any other surgical complications (secondary outcome) in mastectomy between two surgical instruments, ultrasonic SonoSurg (R) scissors (US) and traditional electrocautery (EC). Materials and methods: In total 728 patients undergoing mastectomy in two adjacent university hospitals were retrospectively evaluated in terms of postoperative bleeding episodes, surgical site infections, skin flap necrosis, and any reoperations for 30 postoperative days. A propensity score matching was performed to acquire balanced groups. Patients consuming medications affecting hemostasis were excluded from the study. A multivariable logistic regression analysis was conducted to define the odds ratio (OR) for each complication separately. A cost analysis was performed. Results: The rate of postoperative bleeding complications was significantly lower in patients operated with US (0.3% vs 11.5%, OR 0.020, 95% CI 0.034-0.14) when compared to EC. The rate of surgical site infections (OR 0.65, 95% CI 0.35-1.23) was similar with both instruments, but there were less skin flap necroses (OR 0.35, 95% CI 0.13-0.98) in US group. For any reoperation, the OR for US was 0.13 (95% CI 0.046-0.39), mainly due to the lower number of acute bleeding complications. Even though the US instrument is more expensive than EC, the total cost of the treatment is lower in patients operated with US (3419 vs. 3475 euro). Conclusions: US seems to be associated with a lower risk of bleeding complications in mastectomy.(c) 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Peer reviewe

    Oncological Safety of Skin-Sparing Mastectomy and Immediate Breast Reconstruction in Extensive Ductal Carcinoma In Situ

    Get PDF
    IntroductionSkin-sparing mastectomy (SSM) with immediate breast reconstruction is the ideal treatment for interested and suitable patients with extensive ductal carcinoma in situ (DCIS). There is no guideline to indicate on how large DCIS the procedure can be performed safely. The primary target of this study was to define the oncological safety of SSM in extensive pure DCIS. The secondary target was to find predictive factors for DCIS upstaging to invasive disease.Materials and methodsA total of 71 consecutive patients with extensive pure DCIS and undergoing SSM with immediate latissimus dorsi (LD) breast reconstruction were retrospectively evaluated.ResultsThe median size of DCIS lesion in preoperative imaging was 60 mm, the median weight of mastectomy specimen was 350 g, and the median resection margin (RM) was 2.0 mm. A total of 20 patients (28%) had an RM less than 0.5 mm and nine patients (13%) had ink positive margins. Six patients having positive RM underwent reoperation. A total of 29 patients (41%) presented invasive cancer foci in final histopathological assessment and nine patients (13%) had an axillary metastasis. Adjuvant therapy was given to 23 patients presenting invasive cancer. There were no local recurrences or distant metastases (0%, 95% confidence interval 0-0.051) during the mean follow-up of 71 mo. None of the factors evaluated predicted upstaging to invasive disease.ConclusionsSSM with immediate breast reconstruction in patients with extensive DCIS is oncologically safe even when the margins are close or positive. Additional invasive foci and solitary axillary lymph node metastases are frequent but do not worsen the outcome.</p

    Same-day mastectomy and axillary lymph node dissection is safe for most patients with breast cancer

    Get PDF
    Background and Objective: The aim of this study was to evaluate the safety of same-day mastectomy, with or without a sentinel node biopsy (SNB) and/or axillary lymph node dissection (ALND). Methods: In this retrospective study, we reviewed 913 consecutive women who underwent a simple mastectomy for breast cancer between the years 2014 and 2019 and were treated either with same-day surgery (SDS) or an overnight stay (OS) regime. We reviewed all surgical complications, any unplanned return to care (RTC) and the rehospitalization rate for 30 postoperative days. Results: A total of 259 patients (28%) were treated with SDS and 654 patients (72%) with an OS regime. There was no difference in RTC (odds ratio: 0.79 [95% confidence interval: 0.53-1.18], p = 0.26) or any major complications between the groups. None of the investigated subgroups, such as patients with previous neoadjuvant therapy, diabetes, obesity (up to a body mass index of 40 kg/m(2)), the American Society of Anaesthesiologist Class of 3, or elderly patients aged 75-84 years, showed an increased complication rate when treated with the SDS regime. Conclusion: A same-day simple mastectomy is safe with SNB and/or ALND. It can be performed safely for most patients with stable co-morbidities.</p

    Iatrogenic pneumothorax after breast reduction surgery caused by local anesthesia infiltration - a case report

    Get PDF
    We present a case of a 44-year-old woman, who underwent bilateral breast reduction mammoplasty and suffered a unilateral pneumothorax that was detected postoperatively. Infiltration of a local anesthetic was considered the cause of the pneumothorax. We recommend a more tangential direction of needle placement when infiltrating a local anesthetic

    Ultrasonic scissors decrease postoperative bleeding complications in mastectomy: A retrospective multicenter cohort study on 728 patients

    Get PDF
    IntroductionThe aim of this study was to evaluate the rate of postoperative bleeding complications (primary outcome) and any other surgical complications (secondary outcome) in mastectomy between two surgical instruments, ultrasonic SonoSurg® scissors (US) and traditional electrocautery (EC).Materials and methodsIn total 728 patients undergoing mastectomy in two adjacent university hospitals were retrospectively evaluated in terms of postoperative bleeding episodes, surgical site infections, skin flap necrosis, and any reoperations for 30 postoperative days. A propensity score matching was performed to acquire balanced groups. Patients consuming medications affecting hemostasis were excluded from the study. A multivariable logistic regression analysis was conducted to define the odds ratio (OR) for each complication separately. A cost analysis was performed.ResultsThe rate of postoperative bleeding complications was significantly lower in patients operated with US (0.3% vs 11.5%, OR 0.020, 95% CI 0.034–0.14) when compared to EC.The rate of surgical site infections (OR 0.65, 95% CI 0.35–1.23) was similar with both instruments, but there were less skin flap necroses (OR 0.35, 95% CI 0.13–0.98) in US group. For any reoperation, the OR for US was 0.13 (95% CI 0.046–0.39), mainly due to the lower number of acute bleeding complications. Even though the US instrument is more expensive than EC, the total cost of the treatment is lower in patients operated with US (3419 vs. 3475 euro).ConclusionsUS seems to be associated with a lower risk of bleeding complications in mastectomy.</p
    corecore