17 research outputs found

    Артропластика тазобедренного сустава у пациентов с ожирением (метаанализ проспективных когортных исследований)

    Get PDF
    Acetabular defects are a major obstacle to achieving good outcomes after revision hip arthroplasty. One way to deal with this problem is to use acetabular augments. We aimed to describe mid-term outcomes of revision hip arthroplasty using acetabular augments.Materials and methods. We analyzed 85 cases (83 patients) of revision hip arthroplasty using acetabular augments performed during 2012-2018 period: 53 women and 30 men with average age of 57±13 years (25-79). Distribution of acetabular defects was: 51 cases — Paprosky IIIA, 17 cases — Paprosky IIIB, 12 cases — Paprosky IIB, 5 cases — Paprosky IIC. 14 patients had chronic pelvic discontinuity. Aseptic loosening was indication for the operation in 83 cases, periprosthetic hip fracture — 1, dislocation — 1. The amount of previously undregone ipsilateral hipsurgeries was 1 in 35 cases, 2 in 25 cases, 3 and more in 25 cases. Average follow-up period was 38±19 months (1-79).Results. The average HHS score improved from 37±7 preoperatively to 73±9 after 3 months and to 80±11 after 12 months postoperatively (p = 0.001). Average VAS score improved from 7±2 preoperatively to 4±1 after 3 months and to 3±1 after 12 months postoperatively (p = 0.001). Stable acetabular fixation was achieved in each case according to X-ray findings at final follow-up. However, radiolucent lines were present around the cup in 10 cases (11.8 %) followed by no clinical evidence of aseptic loosening. Hip center of rotation was restored from 26.40±18.38 mm (4-75) preoperatively to 4.78±5.02 mm (0-20) postoperatively relatively to 0 point. Complications manifested in 9 out of 85 cases (10,6%). Distribution of complications was: periprosthetic joint infection in 6 cases, recurrent dislocation — 2, periprosthetic hip fracture — 1.7 patients required implant removal and exchange.Conclusions. Good mid-term outcomes can be achieved using acetabular augments during hip revision surgery in setting of acetabular defects. Acetabular augments are a reliable option in case of Paprosky IIIB, IIIA defects and chronic pelvic discontinuity, providing good mechanical stability.Цель исследования — оценить, влияет ли ожирение пациентов, которым выполняется тотальное эндопротезирование тазобедренного сустава, на длительность операции и стационарного лечения, объем кровопотери, частоту осложнений и летальных исходов.Материал и методы. Нами был выполнен анализ литературных источников, полученных из баз данных PubMed, EBSCO, Cochrane, WanFang и CNKI (Китайская национальная инфраструктура знаний). В метаанализ были включены результаты 24 клинических исследований, которые охватывали 156 914 участников, из них 46 782 страдало ожирением и морбидным ожирением. Оценка проводилась с помощью программы Revman 5.3.Результаты. У пациентов с ИМТ30 оперативное вмешательство занимало больше времени по сравнению с пациентами, имеющими нормальный показатель ИМТ: WMD = -5,14 (95% ДИ -8,13 ... -2,14) (мин), р0,001. Частота вывихов после операции составила RR = 0,07 (95% ДИ = 0,59-0,84) р0,001, частота инфекционных осложнений RR = 0, 56 (95% ДИ 0,50-0,62) (p0, 001) и объема кровопотери WMD = -181,39 (95% ДИ = -293,26 ... -69,52) (мл), p = 0,001. Показатели шкалы Харриса через 5 лет после операции, отражающие функциональные результаты оперативного лечения, у пациентов с ожирением имели более низкие величины, чем при нормальном ИМТ; WMD = 2,85 (95% ДИ 1,04-4,66), p = 0,002. Сроки стационарного лечения, тем не менее, не имели существенной разницы между группами пациентов с нормальным и аномальным весом тела WMD = 0,30, (95% ДИ 0,34-0,95) (дней), p = 0,36.Выводы. Избыточный объем подкожной жировой клетчатки создает дополнительные технические трудности при установке эндопротеза, что, в конечном счете, сказывается как на увеличении продолжительности и объеме операции, так и на кровопотери. При этом у пациентов с повышенным ИМТ возрастает частота послеоперационных вывихов, инфекционных осложнений, снижаются функциональные результаты хирургического лечения. В конечном итоге, ожирение отрицательно влияет на клиническую эффективность тотального первичного эндопротезирования тазобедренного сустава

    Хирургическое лечение пациентов с патологией коленного сустава и деформациями нижних конечностей: систематический обзор литературы

    Get PDF
    Background. In patients with knee pathology, a phased approach to surgical treatment is often used: first, corrective osteotomies and then, if necessary, arthroplasty. This technique allows achieving optimal results of treatment. The study aimed to determine promising methods of surgical treatment of patients with knee pathology and deformities of the lower limb axis. Material and Methods. Publication search was conducted in the databases of eLibrary, PubMed, and Scopus from 2000 to 2020 (a search period of 20 years) using the following keywords: deformity of the lower limb axis, deformity correction, and total knee arthroplasty. Demographic data of the patients, features of surgical techniques, and treatment results were analyzed. Results. The literature search identified 1,232 publications, of which 12 studies that analyzed a total of 2.428 patients were included in this review. The surgical treatment covered the period from 1987 to 2018. The average follow-up period was 64.17.4 months, the average patient age was 58.81.4 years, the average duration of surgery was 114.23.9 min, and the average volume of blood loss was 484.030.0 mL. The fixation period with a metal plate, from the moment of osteotomy to hardware removal, was on average 18.01.8 months. Conclusion. Corrective osteotomies can prevent or delay knee replacement by an average of 11.8 years. Osteotomy preceding total arthroplasty does not negatively affect the survival of endoprosthesis, and its results are comparable with the medium- and long-term results of primary arthroplasty.Актуальность. У пациентов с патологией коленного сустава часто используется этапный подход к хирургическому лечению: сначала корригирующие остеотомии, а затем, при необходимости эндопротезирование. Такая тактика позволяет добиться оптимальных конечных результатов лечения. Целью данного обзора является определение перспективных способов хирургического лечения пациентов с патологией коленного сустава в сочетании с деформациями оси нижней конечности. Материал и методы. Поиск публикаций проводили в базах данных eLIBRARY, PubMed и Scopus с глубиной поиска 20 лет (с 2000 по 2020 г.) по ключевым словосочетаниям: деформация оси конечности (deformity of the lower limb axis), корригирующая остеотомия (deformity correction), тотальное эндопротезирование коленного сустава (total knee arthroplasty). Были проанализированы демографические данные пациентов, особенности хирургических вмешательств и результаты лечения. Результаты. По результатам поиска было найдено 1232 публикации, для анализа отобрано 12 исследований, в которые вошли 2428 пациентов. Сроки оперативного лечения пациентов охватили период с 1987 по 2018 г. Срок наблюдения составил в среднем 64,17,4 мес., средний возраст пациентов составил 58,81,4 года, средняя продолжительность операции 114,23,9 мин., средний объем кровопотери 484,030,0 мл. Время фиксации металлоконструкцией, прошедшее от момента остеотомии до удаления, составило в среднем 18,01,8 мес. Заключение. Корригирующие остеотомии могут предотвратить эндопротезирование или отсрочить его в среднем на 11,8 лет. Остеотомия, предшествующая тотальному эндопротезированию, не оказывает отрицательного влияния на выживаемость эндопротеза, ее результаты сопоставимы со среднесрочными и долгосрочными результатами первичного эндопротезирования

    Раскол керамического вкладыша эндопротеза тазобедренного сустава: клинический случай

    Get PDF
    Background. Ceramic component fracture is a severe complication of primary and revision total hip arthroplasty, leading to multiple revision surgeries. Case report. This report of rare clinical case of ceramic liner fracture. Fifteen months after a planned left hip replacement, the patient experienced anterior surface pain in the area of the operated joint accompanied by creaking, so the patient went for a consultation. Based on the results of the consultation, the patient was urgently hospitalized and underwent a delayed surgery for revision arthroplasty. Radiologically, there was varus position of the femoral component, dislocation of the bearings. MSCT showed ceramic liner fracture and fragment dislocation. Intraoperatively, the multifragmentary fracture of the liner, significant damage to the head, and retroversion of the acetabular component (retroversion was detected on the preoperative CT scan) were identified. All components of the endoprosthesis and tribologic bearings were replaced with identical ones, total synovectomy was performed, and the wound was cleaned and sanitized. Conclusion. The presented case report demonstrates the danger of incorrect positioning of the components when using a ceramic bearings. In this case, retroversion of the acetabular component and varus position of the femoral component resulted in a reduced contact area between the head and the liner, which caused the ceramic to fracture. The described observation confirms the need for further in-depth study of the ceramic bearings in order to prevent ceramic component fracture, as it leads to severe complications and significant economic costs.Актуальность. Раскол керамических компонентов является тяжелым осложнением первичного и ревизионного тотального эндопротезирования тазобедренного сустава, приводящим к многократным ревизионным операциям. Описание клинического наблюдения. Представляем редкий клинический случай раскола керамического вкладыша. Через 15 мес. после проведения планового эндопротезирования левого тазобедренного сустава у пациента появились боли по передней поверхности в области оперированного сустава, сопровождающиеся скрипами, вследствие чего пациент обратился за медицинской помощью. По результатам консультации пациент был экстренно госпитализирован и прооперирован в отсроченном порядке в объеме ревизионного эндопротезирования. Рентгенологически отмечались варусное положение бедренного компонента, дислокация пары трения. По данным МСКТ выявлены раскол керамического вкладыша и дислокация фрагментов. Интраоперационно обнаружены мультифрагментарный раскол вкладыша, значительное повреждение головки. На дооперационной КТ была выявлена ретроверсия вертлужного компонента. Выполнены замена всех компонентов эндопротеза и трибологической пары на идентичную, тотальная синовэктомия, рана промыта и санирована. Заключение. Представленный клинический случай демонстрирует опасность неправильного положения компонентов при использовании керамической пары трения. В приведенном наблюдении ретроверсия вертлужного компонента и варусное положение бедренного компонента привели к уменьшению площади контакта головки и вкладыша, что повлияло на раскол керамики. Описанное наблюдение подтверждает необходимость дальнейшего изучения керамической пары трения с целью профилактики раскола керамических компонентов, так как это приводит к тяжелым осложнениям и значительным экономическим затратам

    ОПЫТ ПРИМЕНЕНИЯ ИНДИВИДУАЛЬНЫХ ТРЕХФЛАНЦЕВЫХ ВЕРТЛУЖНЫХ КОМПОНЕНТОВ ПРИ РЕВИЗИОННОМ ЭНДОПРОТЕЗИРОВАНИИ ТАЗОБЕДРЕННОГО СУСТАВА

    Get PDF
    Extensive defects of acetabulum especially accompanied by pelvis discontinuity at the level of acetabulum pose a serious challenge in revision hip replacement and create additional complexity in fixing the acetabular component. One of the perspective options to solve the above issue is the use of custom triflange acetabular components (CTAC) designed based on preoperative computer tomography given the specifics of bone defects of the patient. Purpose of the study — to evaluate the outcomes of CTAC use in revision hip replacement.Materials and methods. The authors analyzed treatment outcomes of 12 patients after revision hip replacement using additive techniques of computer simulation and 3D printing CTAC. Follow up period after the surgery averaged 7±3 months (from one to ten months). 7 out of 12 patients had acetabular defects of Paprosky 3B type, 4 patients had defects of Paprosky 3A and in one patient — of Paprosky 2C.Results. Two out of twelve patients had prosthesis dislocations that required revision hip surgery, one of those patients underwent open reduction of dislocation with wound debridement, another patient underwent replacement of articulating couple of acetabular component. Total scores under Harris Hip Score and paint VAS score prior to treatment was 28±7 and 7±1 points respectively, postoperative scores were 76±9 and 3±1 respectively.Conclusion. The application of additive techniques for revision hip replacement in patients with extensive acetabular and pelvic defects allows to make a precise preoperative planning, to restore joint rotation center, to reconstruct bone defects and to securely fix triflange acetabular component that altogether significantly improve treatment outcomes and patients satisfaction with the surgery.Значительные дефекты вертлужной впадины, особенно сопровождающиеся нарушением целостности тазового кольца, являются серьезной проблемой ревизионного эндопротезирования тазобедренного сустава и создают дополнительные сложности для фиксации ацетабулярного компонента эндопротеза. Одним из перспективных вариантов решения описанной проблемы является использование индивидуальных трех- фланцевых вертлужных компонентов (CTAC — Custom Triflange Acetabular Component), проектируемых на основе предоперационной компьютерной томографии с учетом особенностей костных дефектов пациента.Цель исследования — оценить эффективность использования CTAC при ревизионном эндопротезировании тазобедренного сустава.Материал и методы. Проанализированы результаты лечения 12 пациентов, перенесших ревизионное эндопротезирование с применением аддитивных технологий компьютерного моделирования и 3D-печати CTAC. Время наблюдения пациентов после эндопротезирования составило в среднем 7±3 мес. (от 1 до 10 мес.). У 7 пациентов из 12 были выявлены дефекты вертлужной впадины типа 3B по W.G. Paprosky, у 4 — типа 3А и у одного — 2С.Результаты. У 2 пациентов из 12 произошли вывихи эндопротеза, что потребовало проведения повторных оперативных вмешательств на тазобедренном суставе, одному из них — открытое вправление вывиха с санацией раны, другому — замена артикулирующей пары ацетабулярного компонента эндопротеза. Суммы баллов по шкале Харриса и визуальной аналоговой шкале боли до лечения составили 28±7 и 7±1, соответственно, после эндопротезирования — 76±9 и 3±1, соответственно.Выводы. Применение аддитивных технологий при ревизионном эндопротезировании тазобедренного сустава у пациентов с обширными костными дефектами вертлужной впадины и таза позволяет провести точное предоперационное планирование, восстановить центр ротации сустава, восполнить дефицит костной ткани, надежно фиксировать индивидуальный трехфланцевый вертлужный компонент эндопротеза, что значительно улучшает результаты лечения и удовлетворенность пациентов операцией

    Индивидуальные трехфланцевые вертлужные компоненты при ревизионном эндопротезировании тазобедренного сустава у пациентов со значительными дефектами вертлужной впадины: планирование, хирургическая техника, результаты

    Get PDF
    Employment of custom triflange acetabular components (CTAC) is one of the few options for pelvic reconstruction in the patients requiring complex acetabulum revisions with Paprosky 2 C, 3 A and 3 B defects and pelvic ring disruption.The purpose of the study was to describe the features of planning, surgical technique, and short-term treatment outcomes of the patients with significant acetabular defects, in which the revision hip arthroplasty was performed using the CTAC.Materials and Methods. A single-center analysis of a series of consecutive patients was performed: 50 complex acetabulum revisions in 47 patients (16 men and 31 women). The average age of the patients was 60±12 years (from 31 to 82; Me 62 years), the average body mass index was 29.7±6.3 kg/m2 (18.4 to 46.3; Me 29.0 kg/m).Results. The mean follow-up was 22±13 months (from 3 to 3.6 years; Me 20 months). The average Harris score increased from 27±7 (from 15 to 39; Me 27) before surgery to 64±16 (from 22 to 90; Me 67) a year after (p0.001). The level of pain according to VAS before surgery was 7±1 points (from 5 to 9; Me 7), after treatment it decreased to 2±1 points (from 0 to 7; Me 1, p0.001). In 17 cases out of 50 (34%), there was at least one complication: dislocations — 7 (14%) cases; infection — 3 (6%); loosening — 2 (4%); complications associated with the femoral component — 4 (8%), including 3 intraoperative fractures and 1 postoperative, associated with loosening of the implant; pronounced disturbances of static and locomotor functions — 2 (4%). 12 cases out of 50 (24%) required another surgery, all of which were performed in a year. The Kaplan-Meyer survival rate for the hip implants was 0.71, for the CTAC — 0.87.Conclusion. Employment of the CTAC for revision hip arthroplasty in the patients with significant acetabulum defects and pelvic ring disruption allows reliable fixation of the endoprosthesis components. The STAC placement technique is more anatomical than use of structural allografts, several augments or sup-cage systems. It allows reconstruction of extensive bone defects, theoretically avoiding the long-term problems with allografts, modular trabecular components, antiprotrusion systems and cup-cage. Although, to prove this, the longer follow-up is needed.Использование индивидуальных трехфланцевых вертлужных компонентов (CTAC — custom triflange acetabular component) является одним из немногих вариантов реконструкции таза для пациентов, нуждающихся в сложных ревизиях вертлужной впадины, сопровождающихся дефектами 2 C, 3 A и 3 B по Paprosky и нарушением целостности тазового кольца.Цель исследования — определить особенности планирования, хирургической техники и краткосрочных результатов лечения пациентов со значительными дефектами вертлужной впадины, у которых при ревизионном эндопротезировании тазобедренного сустава применялись индивидуальные трехфланцевые вертлужные компоненты.Материал и методы. Был проведен одноцентровый анализ серии последовательных пациентов: 50 сложных ревизий вертлужной впадины у 47 пациентов (16 мужчин и 31 женщина). Средний возраст пациентов составил 60±12 лет (от 31 до 82 лет; Ме 62 года), среднее значение индекса массы тела — 29,7±6,3 кг/м2 (от 18,4 до 46,3 кг/м2; Ме 29,0 кг/м2).Результаты. Средний срок наблюдения составил 22±13 мес. (от 3 мес. до 3,6 лет; Ме 20 мес.). Среднее значение по шкале Харриса увеличилось с 27±7 (от 15 до 39; Ме 27) до операции до 64±16 (от 22 до 90; Ме 67) через год после (р0,001). Уровень болевого синдрома по ВАШ до оперативного вмешательства составлял 7±1 баллов (от 5 до 9; Ме 7), после лечения снизился до 2±1 баллов (от 0 до 7; Ме 1) (р0,001). В 17 случаях из 50 (34%) развилось, по крайней мере, одно осложнение: вывихи — 7 (14%) случаев; инфекция — 3 (6%); расшатывание — 2 (4%); осложнения, связанные с бедренным компонентом — 4 (8%), включая 3 интраоперационных перелома и 1 послеоперационный, сопряженный с расшатыванием имплантата; выраженные нарушения статико-локомоторных функций — 2 (4%). В 12 случаях из 50 (24%) потребовалось проведение очередных оперативных вмешательств — все они были выполнены в течение первого года после операции. Выживаемость по Каплану – Мейеру имплантата тазобедренного сустава целиком составила 0,71, выживаемость CTAC — 0,87.Заключение. Применение индивидуальных трехфланцевых вертлужных компонентов при ревизионном эндопротезировании тазобедренного сустава у пациентов со значительными дефектами вертлужной впадины и разобщением целостности тазового кольца позволяет провести надежную фиксацию компонентов эндопротеза. Методика установки СТАС является более анатомичной по сравнению с применением структурных аллографтов, нескольких аугментов или систем сup-сage и позволяет реконструировать обширные костные дефекты, теоретически избегая долгосрочных проблем аллотрансплантатов, модульных трабекулярных компонентов, антипротрузионных систем и сup-сage, но для доказательств этого необходимы более долгосрочные наблюдения

    Основные тренды в эндопротезировании тазобедренного сустава на основании данных регистра артропластики НМИЦ ТО им. Р.Р. Вредена с 2007 по 2020 г.

    Get PDF
    This publication is the official report describing all total hip arthroplasty procedures registered in the database from 01.01.2007 to 31.12.2020. During this period, 74762 operations were performed: 67019 (89.64%) primary and 7743 (10.36%) revision. The proportion of males and females underwent primary arthroplasty was 41.1% and 59.0%, respectively. The age of patients with primary arthroplasty was 57.8 years (95% CI from 57.7 to 57.9), with revision 59.3 years (95% CI from 59.0 to 59.6). The absolute number of primary hip arthroplasty procedures added into the database increased annually from 2007 to 2012. Since 2015, there has been a trend towards a decrease in the number of hip arthroplasty, due to the more intensive growth in the number of knee replacements performed. The number of revision hip arthroplasty operations varies from year to year with a clear tendency to increase, except 2020. The large proportion of revisions are accounted for by early revisions performed in the first years after primary hip arthroplasty, as well as early re-revisions. The main types of implants fixation on primary arthroplasty during the reporting period were cementless (50.89%) and hybrid (32.33%). In patients of older age groups, there is a significant decrease in the proportion of cementless fixation, while the proportion of hybrid, reverse hybrid and cemented structures is increasing. There are significant fluctuations in the ratio of different types of implants fixation in different years.Данная публикация является официальным отчетом, описывающим все операции тотального эндопротезирования (ТЭП) тазобедренного сустава (ТБС), зарегистрированные в базе данных с 01.01.2007 по 31.12.2020 г. За этот период было выполнено 74 762 операции: 67 019 (89,64%) первичных и 7743 (10,36%) ревизионных. Доля пациентов мужского и женского пола при первичном ТЭП составила 41,1% и 59,0% соответственно. Возраст пациентов при первичном ТЭП в среднем составил 57,8 лет (95% ДИ от 57,7 до 57,9), при ревизионном 59,3 лет (95% ДИ от 59,0 до 59,6). Абсолютное число операций первичного ТЭП ТБС, внесенных в базу регистра, ежегодно увеличивалось с 2007 по 2012 г. С 2015 г. наблюдается тенденция к постепенному уменьшению числа ТЭП ТБС в связи с более интенсивным ростом выполняемых ревизионных артропластик коленного сустава. Количество ревизионных операций колеблется от года к году с явной тенденцией к увеличению, за исключением 2020 г. Большая доля ревизий приходится на ранние ревизии, выполненные в первые годы после первичного ТЭП ТБС, а также на ранние ре-ревизии. Основными типами фиксации эндопротезов при первичном ТЭП в течение отчетного периода являлись бесцементная (50,89%) и гибридная (32,33%). У пациентов старших возрастных групп отмечается значительное уменьшение доли бесцементной фиксации, при этом нарастают доли гибридных, реверс-гибридных и цементируемых конструкций. Отмечаются значительные колебания в соотношениях различных по типу фиксации имплантатов в разные годы
    corecore