9 research outputs found

    Impact of asymmetric tethering on outcomes after edge-to-edge mitral valve repair for secondary mitral regurgitation

    Get PDF
    BACKGROUND The impact of postero-anterior and medio-lateral mitral valve (MV) tethering patterns on outcomes in patients undergoing transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR) is unknown. METHODS The ratio of the posterior to anterior MV leaflet angle (PLA/ALA) in MV segment 2 was defined as postero-anterior tethering asymmetry. Medio-lateral tethering asymmetry was assessed as the ratio of the medial (segment 3) to lateral (segment 1) MV tenting area. We used receiver-operating characteristics and a Cox regression model to identify cut-off values of asymmetric anteroposterior and medio-lateral tethering for prediction of 2~year all-cause mortality after TMVR. RESULTS Among 178 SMR patients, postero-anterior tethering was asymmetric in 67 patients (37.9%, PLA/ALA ratio > 1.54). Asymmetric medio-lateral tethering (tenting area ratio > 1.49) was observed in 49 patients (27.5%). M-TEER reduced MR to ≀ 2 + in 92.1% of patients; MR reduction was less effective in the presence of asymmetric postero-anterior tethering (p = 0.02). A multivariable Cox regression model identified both types of asymmetric MV tethering to be associated with increased all-cause 2-year mortality (postero-anterior tethering asymmetry: HR = 2.77, CI 1.43-5.38; medio-lateral tethering asymmetry: HR = 2.90, CI 1.54-5.45; p < 0.01). CONCLUSIONS Asymmetric postero-anterior and medio-lateral MV tethering patterns are associated with increased 2-year mortality in patients undergoing M-TEER for SMR. A detailed echocardiographic analysis of MV anatomy may help to identify patients who profit most from M-TEER

    Cardio‐hepatic syndrome in patients undergoing mitral valve transcatheter edge‐to‐edge repair

    Get PDF
    Aims The impact of the cardio-hepatic syndrome (CHS) on outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) for relevant mitral regurgitation (MR) is unknown. The objectives of this study were three-fold: (i) to characterize the pattern of hepatic impairment, (ii) to investigate the prognostic value of CHS, and (iii) to evaluate the changes in hepatic function after M-TEER. Methods and results Hepatic impairment was quantified by laboratory parameters of liver function. In accordance with existing literature, two types of CHS were distinguished: ischaemic type I CHS (elevation of both transaminases) and cholestatic type II CHS (elevation of two out of three parameters of hepatic cholestasis). The impact of CHS on 2-year mortality was evaluated using a Cox model. The change in hepatic function after M-TEER was assessed by laboratory testing at follow-up. We analysed 1083 patients who underwent M-TEER for relevant primary or secondary MR at four European centres between 2008 and 2019. Ischaemic type I and cholestatic type II CHS were observed in 11.1% and 23.0% of patients, respectively. Predictors for 2-year all-cause mortality differed by MR aetiology. While in primary MR cholestatic type II CHS was independently associated with 2-year mortality, ischaemic CHS type I was an independent mortality predictor in secondary MR patients. At follow-up, patients with MR reduction ≀2+ (obtained in 90.7% of patients) presented with improved parameters of hepatic function (median reduction of 0.2 mg/dl, 0.2 U/L and 21 U/L for bilirubin, alanine aminotransferase and gamma-glutamyl transferase, respectively, p < 0.01). Conclusions The CHS is frequently observed in patients undergoing M-TEER and significantly impairs 2-year survival. Successful M-TEER may have beneficial effects on CHS

    Identification and characterisation of VW-resident stem cells in coronary vessels

    No full text
    In der vorliegenden Arbeit gelang es die Bedeutung sowie die Aktivierung und Mobilisierung der koronaren GefĂ€ĂŸwand-residenten Stammzellen bei der Angiogenese des Herzgewebes mittels Cardiac Angiogenesis Assay prĂ€zise zu charakterisieren und beeinflussende Faktoren zu identifizieren.In the present work the activation and mobilisation of vascular wall resident stem cells of coronary vessels could be characterised during the angiogenesis of cardiac tissue using the Cardiac Angiogenesis Assay. Moreover influencing factors were identified

    Comparison of balanced and unbalanced crystalloids as resuscitation fluid in patients treated for cardiogenic shock

    No full text
    Abstract Background The efficacy and safety of saline versus balanced crystalloid solutions in ICU-patients remains complicated by exceptionally heterogenous study population in past comparative studies. This study sought to compare saline and balanced crystalloids for fluid resuscitation in patients with cardiogenic shock with or without out-of-hospital cardiac arrest (OHCA). Methods We retrospectively analyzed 1032 propensity score matched patients with cardiogenic shock from the Munich University Hospital from 2010 to 2022. In 2018, default resuscitation fluid was changed from 0.9% saline to balanced crystalloids. The primary endpoint was defined as 30-day mortality rate. Results Patients in the saline group (n = 516) had a similar 30-day mortality rate as patients treated with balanced crystalloids (n = 516) (43.1% vs. 43.0%, p = 0.833), but a higher incidence of new onset renal replacement therapy (30.2% vs 22.7%, p = 0.007) and significantly higher doses of catecholamines. However, OHCA-patients with a lactate level higher than 7.4 mmol/L had a significantly lower 30-day mortality rate when treated with saline (58.6% vs. 79.3%, p = 0.013). In addition, use of balanced crystalloids was independently associated with a higher mortality in the multivariate cox regression analysis after OHCA (hazard ratio 1.43, confidence interval: 1.05–1.96, p = 0.024). Conclusions In patients with cardiogenic shock, use of balanced crystalloids was associated with a similar all-cause mortality at 30 days but a lower rate of new onset of renal replacement therapy. In the subgroup of patients after OHCA with severe shock, use of balanced crystalloids was associated with a higher mortality than saline. Trial registration: LMUshock registry (WHO International Clinical Trials Registry Platform Number DRKS00015860)

    Multicenter Experience With the Transcatheter Leaflet Repair System for Symptomatic Tricuspid Regurgitation.

    No full text
    BACKGROUND Transcatheter treatment techniques for tricuspid regurgitation (TR) have evolved in recent years, with leaflet repair being the most commonly used, but thus far evidence on the PASCAL and PASCAL Ace system is based mainly on compassionate use data. OBJECTIVES This is the first report on commercial use in a multicenter study with a large patient cohort investigating the safety and efficacy of the PASCAL and PASCAL Ace system in the treatment of TR. METHODS In a retrospective, multicenter, observational setting, data from all consecutive patients undergoing leaflet repair for TR at 8 centers was collected, including a centralized analysis of echocardiographic data. RESULTS A total of 235 high-risk patients (mean age 78 ± 8 years, 49% women, mean Society of Thoracic Surgeons Predicted Risk of Mortality score 8.6% ± 6.8%) were included. TR was functional in 87% of patients and graded severe or higher in 91%. TR was successfully reduced to moderate or less in 78% of patients (P < 0.001). Procedural success was 78% (n = 153). At the latest available follow-up (median 173 days), TR reduction was sustained (78% with TR moderate or less; P < 0.001), and echocardiography showed indications of right ventricular remodeling (mean right ventricular end-diastolic diameter 56 ± 9 mm vs 53 ± 9 mm; P < 0.001). Patients' symptoms diminished significantly (63% were in New York Heart Association functional class I or II at follow-up; P < 0.001). In a device-specific analysis, the PASCAL and PASCAL Ace showed no difference in TR reduction (postprocedural TR moderate or less in 77% vs 78%; P = 0.82). CONCLUSIONS In early clinical experience, the PASCAL (Ace) leaflet repair system has high technical and procedural success rates with efficient TR reduction and significant clinical and echocardiographic improvement at follow-up

    Transcatheter Aortic Valve Replacement with the Self-Expandable Core Valve Evolut Prosthesis Using the Cusp-Overlap vs. Tricusp-View

    No full text
    Despite the rapid increase in experience and technological improvement, the incidence of conduction disturbances in patients undergoing transcatheter aortic valve replacement (TAVR) with the self-expandable CoreValve Evolut valve remains high. Recently, a cusp-overlap view (COP) implantation technique has been proposed for TAVR with self-expandable valves offering an improved visualization during valve expansion compared to the three-cusp view (TCV). This study aims to systematically analyze procedural outcomes of TAVR patients treated with the CoreValve Evolut valve using a COP compared to TCV in a high-volume center. The primary endpoint was technical success according the 2021 VARC-3 criteria. A total of 122 consecutive patients (61 pts. TCV: April 2019 to November 2020; 61 pts. COP: December 2020 to October 2021) that underwent TAVR with the CoreValve Evolut prosthesis were included in this analysis. Although there was no difference in the primary endpoint technical success between TCV and COP patients (93.4% vs. 90.2%, OR 0.65, 95% CI 0.16, 2.4, p = 0.51), we observed a significantly lower risk for permanent pacemaker implantation (PPI) among COP patients (TCV: 27.9% vs. COP: 13.1%, OR 0.39, 95% CI 0.15, 0.97, p = 0.047). Implantation of the CoreValve Evolut prosthesis using the COP might help to reduce the rate of PPI following TAVR

    Cardio-hepatic syndrome in patients undergoing transcatheter mitral valve edge-to-edge repair.

    Get PDF
    AIMS The impact of the cardio-hepatic syndrome (CHS) on outcomes in patients undergoing transcatheter edge-to-edge repair (M-TEER) for relevant mitral regurgitation (MR) is unknown. The objectives of this study were three-fold: (I) to characterize the pattern of hepatic impairment, (II) to investigate the prognostic value of CHS, and (III) to evaluate the changes in hepatic function after M-TEER. METHODS AND RESULTS Hepatic impairment was quantified by laboratory parameters of liver function. In accordance with existing literature, two types of CHS were distinguished: Ischemic type I CHS (elevation of both transaminases) and cholestatic type II CHS (elevation of two out of three parameters of hepatic cholestasis). The impact of CHS on two-year mortality was evaluated using a Cox model. The change in hepatic function after M-TEER was assessed by laboratory testing at follow-up. We analyzed 1083 patients who underwent M-TEER for relevant primary or secondary MR at four European centers between 2008 and 2019. Ischemic type I and cholestatic type II CHS were observed in 11.1% and 23.0% of patients, respectively. Predictors for two-year all-cause mortality differed by MR etiology. While in primary MR cholestatic type II CHS was independently associated with two-year mortality, ischemic CHS type I was an independent mortality predictor in SMR patients. At follow-up, patients with MR reduction ≀2+ (obtained in 90.7% of patients) presented with improved parameters of hepatic function (median reduction of 0.2mg/dl, 0.2U/l and 21U/l for bilirubin, ALT and GGT, respectively, p<0.01). CONCLUSIONS CHS is frequently observed in patients undergoing M-TEER and significantly impairs two-year survival. Successful M-TEER may have beneficial effects on CHS
    corecore