19 research outputs found

    Einfluss von Flavonoiden auf Stress-induzierte Thrombozytenaktivierung

    Get PDF

    Combined Effect of Acute Altitude Exposure and Vigorous Exercise on Platelet Activation

    Get PDF
    Exposure to high altitudes and exercise alters body's physiology and may cause acute cardiovascular events. Platelet activation is one of the key players in these events. Therefore, we investigated the effect of vigorous exercise at higher altitude (2650 m) on platelet aggregation and serum markers of platelet activation. 14 healthy subjects performed a step incremental ergometer test until exhaustion at the Environmental Research Station (UFS, 2650 m) at Zugspitze. Platelet aggregation and serum levels of endothelin-1, soluble p-selectin, platelet factor 4 and Chromogranin A were measured. Platelet activation was significantly enhanced after exercise at high altitude compared to measures immediately prior exercise. We detected significantly enhanced serum levels of endothelin-1 and soluble p-selectin whereas chromogranin A and platelet factor 4 remained unchanged. This effect might be due to increased endothelin-1 levels causing pulmonary vasoconstriction, rheological changes and direct platelet activation. This might be of clinical relevance, especially in patients with pre-existing diseases

    oxLDL Downregulates the Dendritic Cell Homing Factors CCR7 and CCL21

    Get PDF
    Introduction. Dendritic cells (DCs) and oxLDL play an important role in the atherosclerotic process with DCs accumulating in the plaques during plaque progression. Our aim was to investigate the role of oxLDL in the modulation of the DC homing-receptor CCR7 and endothelial-ligand CCL21. Methods and Results. The expression of the DC homing-receptor CCR7 and its endothelial-ligand CCL21 was examined on atherosclerotic carotic plaques of 47 patients via qRT-PCR and immunofluorescence. In vitro, we studied the expression of CCR7 on DCs and CCL21 on human microvascular endothelial cells (HMECs) in response to oxLDL. CCL21- and CCR7-mRNA levels were significantly downregulated in atherosclerotic plaques versus non-atherosclerotic controls [90% for CCL21 and 81% for CCR7 (P < 0.01)]. In vitro, oxLDL reduced CCR7 mRNA levels on DCs by 30% and protein levels by 46%. Furthermore, mRNA expression of CCL21 was significantly reduced by 50% (P < 0.05) and protein expression by 24% in HMECs by oxLDL (P < 0.05). Conclusions. The accumulation of DCs in atherosclerotic plaques appears to be related to a downregulation of chemokines and their ligands, which are known to regulate DC migration. oxLDL induces an in vitro downregulation of CCR7 and CCL21, which may play a role in the reduction of DC migration from the plaques

    Permanent pacemaker dependency in patients with new left bundle branch block and new first degree atrioventricular block after transcatheter aortic valve implantation

    Get PDF
    Conduction disorders with need for permanent pacemaker (PPM) implantation remain frequent complications after transcatheter aortic valve implantation (TAVI). Up to 22% of PPM after TAVI are implanted for new onset left bundle branch block (LBBB) and atrioventricular block (AVB) I. However, clinical benefit and predictors of ventricular pacing in TAVI patients receiving PPM for this indication remain unclear. We retrospectively evaluated pacemaker interrogation data of patients who received a PPM post TAVI for new LBBB and new AVB I. The primary endpoint of this study was relevant ventricular pacing (ventricular pacing rate: Vp ≥ 1%) at the first outpatient pacemaker interrogation. Secondary endpoints were predictors for relevant ventricular pacing. At the first pacemaker interrogation (median follow up at 6.23 2.8-14.8 months), median ventricular pacing frequency was 1.0{\%} 0.1-17.8. Out of 61 patients, 36 (59{\%}) had Vp rates ≥ 1{\%}. Patients with frequent ventricular pacing showed longer QRS duration (155~ms ± 17~ms vs. 144~ms ± 18~ms, p = 0.018) at the time of PPM implantation and were less likely treated with a balloon-expandable Edwards Sapiens Valve (39{\%} vs. 12{\%}, p = 0.040). Our findings suggest that the majority of patients with new LBBB and new AVB I after TAVI show relevant ventricular pacing rates at follow up. Further prospective studies are necessary to identify patients at higher risk of pacemaker dependency

    Lower frequency routine surveillance endomyocardial biopsies after heart transplantation

    Get PDF
    In heart transplantation (HTx) patients, routine surveillance endomyocardial biopsies (rsEMB) are recommended for the detection of early cardiac allograft rejection. However, there is no consensus on the optimal frequency of rsEMB. Frequent rsEMB have shown a low diagnostic yield in the new era of potent immunosuppressive regimen. Efficacy and safety of lower frequency rsEMB have not been investigated so far. In this retrospective, single centre, observational study we evaluated 282 patients transplanted between 2004 and 2014. 218 of these patients were investigated by rsEMB and symptom-triggered EMB (stEMB). We evaluated EMB results, complications, risk factors for rejection, survival 1 and 5 years as well as incidence of cardiac allograft vasculopathy (CAV) 3 years after HTx. A mean of 7.1 +/- 2.5 rsEMB were conducted per patient within the first year after HTx identifying 7 patients with asymptomatic and 9 patients with symptomatic acute rejection requiring glucocorticoide pulse therapy. Despite this relatively low frequency of rsEMB, only 6 unscheduled stEMB were required in the first year after HTx leading to 2 additional treatments. In 6 deaths among all 282 patients (2.1%), acute rejection could not be ruled out as a potential underlying cause. Overall survival at 1 year was 78.7% and 5-year survival was 74%. Incidence of CAV was 17% at 3-year follow-up. Morbidity and mortality of lower frequency rsEMB are comparable with data from the International Society for Heart and Lung Transplantation (ISHLT) registry. Consensus is needed on the optimal frequency of EMB

    Impairment of Quality of Life in Patients with Implanted Subcutaneous Cardioverter Defibrillator (S-ICD) Compared to Implanted Transvenous Cardioverter Defibrillator Therapy

    Get PDF
    Background: The subcutaneous cardioverter defibrillator (S-ICD) has been shown to be a viable alternative to transvenous ICDs (TV-ICD) in all patients at risk of sudden cardiac death (SCD) but without pacing indication.Aim: The aim of this study was to examine the impact of therapy with current S-ICD devices on quality of life (QoL) in comparison to patients with TV-ICD devices.Methods: In our single-centre study, 52 consecutive patients with S-ICD and 52 matched patients with TV-ICD were analysed. QoL has been assessed by a standardized questionnaire (EQ-5D-3L, modified). Additionally, clinical baseline and follow-up data were evaluated.Results: Two-thirds of the total study population reported restrictions in daily routine compared to their life before ICD implantation. A total of 27.7% of S-ICD patients stated to expect an improvement of QoL by deactivation or explantation of their defibrillator compared to only 6.4% of patients with TV-ICD (p=0.006), which was mainly caused by discomfort and pain from the S-ICD pocket (relevant discomfort and pain in 32.6% vs 11.5%;p<0.01).Limitations: Main limitation of the study is that quality of life was assessed for one single time point only and time since implantation differed significantly between S-ICD and TV-ICD. Furthermore our collective is younger, and, due to the high proportion of patients without cardiomyopathy, the mean EF is better than usual ICD collective. The absence of heart failure in about the half of our patients might have relevant impact on our QoL analysis. Conclusion: A relevant proportion of S-ICD patients expects an improvement of QoL by explantation of the device. Of note, this impression was not driven by the fear of receiving shocks but mainly by discomfort and pain caused by the pulse generator

    Impairment of Quality of Life among Patients with Wearable Cardioverter Defibrillator Therapy (LifeVest®): A Preliminary Study

    Get PDF
    Background. Wearable cardioverter defibrillator (WCD) therapy is feasible and safe in patients as a transient protection against sudden cardiac death (SCD). However, the impact of WCD therapy on quality of life (QoL) has not been studied. Methods. In our single-centre study, 109 consecutive patients with a prescription of WCD were retrospectively analysed. Quality of life has been assessed by a standardized questionnaire (EQ-5D-3L, modified). Additionally, clinical baseline and follow-up data and recorded arrhythmic episodes were evaluated. Results. Mean WCD therapy time was 56.2 (± 42.4) days, with a daily wear time of 19.7 (± 5) hours. A total of 3441 arrhythmia episodes were detected. Of these, 27 (1%) were adequate but did not require shock therapy. Likewise, no inadequate shock therapy occurred. WCD therapy negatively affected quality of life: 43% of patients reported mental health issues. 37% reported pain or discomfort. Self-care, usual activities, and mobility were restricted in 17%, 48%, and 36%, respectively. 29% were afraid of receiving shock therapy, and 48% suffered from sleep disturbance. However, 64% indicated having felt safe during WCD therapy. Accordingly, average quality of life was rated 70/100 points. Conclusion. In our cohort, no SCD was prevented by WCD therapy. In contrast, in this preliminary study quality of life was reduced. Thus, careful recommendation of WCD therapy for high risk patients should be considered

    Determination of time of death by blinded post-mortem interrogation of cardiac implantable electrical devices

    Get PDF
    Postmortal interrogation of cardiac implantable electrical devices (CIED) may contribute to the determination of time of death in forensic medicine. Recent studies aimed to improve estimation of time of death by combining findings from autopsy, CIED interrogation and patients ' medical history. CIED from deceased undergoing forensic autopsy were included, if time of death remained unclear after forensic assessment. CIED explanted from deceased with known time of death were analysed as a control cohort. CIED were sent to our device interrogation lab and underwent analysis blinded for autopsy findings, medical history and police reports. The accuracy of time of death determination and the accuracy of time of death in the control cohort served as primary outcome. A total of 87 CIED were analysed. The determination of time of death was possible in 54 CIED (62%, CI 52-72%). The accuracy of the estimated time of death was 92.3% in the control cohort. Certain CIED type and manufacturers were associated with more successful determination. Blinded postmortal analysis enables a valid determination of the time of death in the majority of CIED. Analysis of explanted CIED in a cardiological core lab is feasible and should be implemented in forensic medicine
    corecore