241 research outputs found

    Significant association of a M129V independent polymorphism in the 5\prime UTR of the PRNP gene with sporadic Creutzfeldt-Jakob disease in a large German case-control study

    Get PDF
    Background: A single nucleotide polymorphism (SNP) in the coding region of the prion protein gene (PRNP) at codon 129 has been repeatedly shown to be an associated factor to sporadic Creutzfeldt-Jakob disease (sCJD), but additional major predisposing DNA variants for sCJD are still unknown. Several previous studies focused on the characterisation of polymorphisms in PRNP and the prion-like doppel gene (PRND), generating contradictory results on relatively small sample sets. Thus, extensive studies are required for validation of the polymorphisms in PRNP and PRND.Methods: We evaluated a set of nine SNPs of PRNP and one SNP of PRND in 593 German sCJD patients and 748 German healthy controls. Genotyping was performed using MALDI-TOF mass spectrometry.Results: In addition to PRNP 129, we detected a significant association between sCJD and allele frequencies of six further PRNP SNPs. No significant association of PRND T174M with sCJD was shown. We observed strong linkage disequilibrium within eight adjacent PRNP SNPs, including PRNP 129. However, the association of sCJD with PRNP 1368 and PRNP 34296 appeared to be independent on the genotype of PRNP 129. We additionally identified the most common haplotypes of PRNP to be over-represented or under-represented in our cohort of patients with sCJD.Conclusion: Our study evaluated previous findings of the association of SNPs in the PRNP and PRND genes in the largest cohorts for association study in sCJD to date, and extends previous findings by defining for the first time the haplotypes associated with sCJD in a large population of the German CJD surveillance study

    Evolution to 200G Passive Optical Network

    Full text link
    New generation passive optical network aims at providing more than 100 Gb/s capacity. Thanks to recent progress enabling a variety of optical transceivers up to 40 Gb/s, many evolution possibilities to 200G PONs (passive optical network) could be investigated. This work proposes two directly deployable cases of evolution to 200G PON based on the combination of these improved optical transceivers and WDM (wavelength division multiplexing). The physical layer of the optical network has been simulated with OptiSystem software to show the communication links performances behavior when considering key components parameters in order to achieve good network design for a given area. The complexity of the proposed architectures and financial cost comparisons are also discussed.Comment: http://www.davidpublishing.com/davidpublishing/Upfile/2/7/2013/2013020707494407.pd

    Synthesis and In Vitro Evaluation of Novel Nortropane Derivatives as Potential Radiotracers for Muscarinic M2 Receptors

    Get PDF
    Disturbances of the cerebral cholinergic neurotransmitter system are present in neurodegenerative disorders. SPECT or PET imaging, using radiotracers that selectively target muscarinic receptor subtypes, may be of value for in vivo evaluation of such conditions. 6β-acetoxynortropane, a potent muscarinic M2 receptor agonist, has previously demonstrated nanomolar affinity and high selectivity for this receptor. Based on this compound we synthesized four nortropane derivatives that are potentially suitable for SPECT imaging of the M2 receptor. 6β-acetoxynortropane and the novel derivatives were tested in vitro for affinity to the muscarinic M1−3 receptors. The original 6β-acetoxynortropane displayed high affinity (Ki = 70–90 nM) to M2 receptors and showed good selectivity ratios to the M1 (65-fold ratio) and the M3 (70-fold ratio) receptors. All new derivatives showed reduced affinity to the M2 subtype and loss of subtype selectivity. It is therefore concluded that the newly synthesized derivatives are not suitable for human SPECT imaging of M2 receptors

    Renewable Energy Opportunities at Yuma Proving Ground, Arizona

    Get PDF
    This document provides an overview of renewable resource potential at Yuma Proving Ground, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations

    Perceived Devaluation and STI Testing Uptake among a Cohort of Street-involved Youth in a Canadian Setting

    Get PDF
    Perceived devaluation has been shown to have adverse effects on the mental and physical health outcomes of people who use drugs. However, the impact of perceived devaluation on sexually transmitted infections (STI) testing uptake among street-involved youth, who face multiple and intersecting stigmas due to their association with drug use and risky sexual practices, has not been fully characterized. Data were obtained between December 2013 and November 2014 from a cohort of street-involved youth who use illicit drugs aged 14–26 in Vancouver, British Columbia. Multivariable generalized estimating equations were constructed to assess the independent relationship between perceived devaluation and STI testing uptake. Among 300 street-involved youth, 87.0% reported a high perceived devaluation score at baseline. In the multivariable analysis, high perceived devaluation was negatively associated with STI testing uptake after adjustment for potential confounders (Adjusted Odds Ratio = 0.38, 95% Confidence Interval 0.15–0.98). Perceived devaluation was high among street-involved youth in our sample and appears to have adverse effects on STI testing uptake. HIV prevention and care programs should be examined and improved to better meet the special needs of street-involved youth in non-stigmatizing ways

    Renewable Energy Assessment Methodology for Japanese OCONUS Army Installations

    Get PDF
    Since 2005, Pacific Northwest National Laboratory (PNNL) has been asked by Installation Management Command (IMCOM) to conduct strategic assessments at selected US Army installations of the potential use of renewable energy resources, including solar, wind, geothermal, biomass, waste, and ground source heat pumps (GSHPs). IMCOM has the same economic, security, and legal drivers to develop alternative, renewable energy resources overseas as it has for installations located in the US. The approach for continental US (CONUS) studies has been to use known, US-based renewable resource characterizations and information sources coupled with local, site-specific sources and interviews. However, the extent to which this sort of data might be available for outside the continental US (OCONUS) sites was unknown. An assessment at Camp Zama, Japan was completed as a trial to test the applicability of the CONUS methodology at OCONUS installations. It was found that, with some help from Camp Zama personnel in translating and locating a few Japanese sources, there was relatively little difficulty in finding sources that should provide a solid basis for conducting an assessment of comparable depth to those conducted for US installations. Project implementation will likely be more of a challenge, but the feasibility analysis will be able to use the same basic steps, with some adjusted inputs, as PNNL’s established renewable resource assessment methodology

    Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month post cataract surgery with primary implantation of an intraocular lens using SRK II versus Pediatric IOL Calculator for pediatric intraocular lens calculation. Pediatric IOL Calculator is a modification of SRK II using Holladay algorithm. This program attempts to predict the refraction of a pseudophakic child as he grows, using a Holladay algorithm model. This model is based on refraction measurements of pediatric aphakic eyes. Pediatric IOL Calculator uses computer software for intraocular lens calculation.</p> <p>Methods</p> <p>This comparative study consists of 31 eyes (24 patients) that successfully underwent cataract surgery and intraocular lens implantations. All patients were 12 years old and below (range: 4 months to 12 years old). Patients were randomized into 2 groups; SRK II group and Pediatric IOL Calculator group using envelope technique sampling procedure. Intraocular lens power calculations were made using either SRK II or Pediatric IOL Calculator for pediatric intraocular lens calculation based on the printed technique selected for every patient. Thirteen patients were assigned for SRK II group and another 11 patients for Pediatric IOL Calculator group. For SRK II group, the predicted postoperative refraction is based on the patient's axial length and is aimed for emmetropic at the time of surgery. However for Pediatric IOL Calculator group, the predicted postoperative refraction is aimed for emmetropic spherical equivalent at age 2 years old. The postoperative refractive outcome was taken as the spherical equivalent of the refraction at 3 month postoperative follow-up. The data were analysed to compare the mean prediction error and the accuracy of predictability of intraocular lens power calculation between SRK II and Pediatric IOL Calculator.</p> <p>Results</p> <p>There were 16 eyes in SRK II group and 15 eyes in Pediatric IOL Calculator group. The mean prediction error in the SRK II group was 1.03 D (SD, 0.69 D) while in Pediatric IOL Calculator group was 1.14 D (SD, 1.19 D). The SRK II group showed lower prediction error of 0.11 D compared to Pediatric IOL Calculator group, but this was not statistically significant (p = 0.74). There were 3 eyes (18.75%) in SRK II group achieved acccurate predictability where the refraction postoperatively was within ± 0.5 D from predicted refraction compared to 7 eyes (46.67%) in the Pediatric IOL Calculator group. However the difference of the accuracy of predictability of postoperative refraction between the two formulas was also not statistically significant (p = 0.097).</p> <p>Conclusions</p> <p>The prediction error and the accuracy of predictability of postoperative refraction in pediatric cataract surgery are comparable between SRK II and Pediatric IOL Calculator. The existence of the Pediatric IOL Calculator provides an alternative to the ophthalmologist for intraocular lens calculation in pediatric patients. Relatively small sample size and unequal distribution of patients especially the younger children (less than 3 years) with a short time follow-up (3 months), considering spherical equivalent only.</p
    corecore