35 research outputs found
The performance of thin NaI(Tl) scintillator plate for dark matter search
A thin (0.05cm) and wide area (5cmX5cm) NaI(Tl) scintillator was developed.
The performance of the thin NaI(Tl) plate, energy resolution, single
photoelectron energy and position sensitivity were tested. An excellent energy
resolution of 20% (FWHM) at 60keV was obtained. The single photoelectron energy
was calculated to be approximately 0.42 0.02keV. Position information in the
5cmx5cm area of the detector was also obtained by analyzing the ratio of the
number of photons collected at opposite ends of the detector. The position
resolution was obtained to be 1cm (FWHM) in the 5cmx5cm area.Comment: 10 pages. Accepted to Journal of Physical Society of Japa
WIMPs search by means of the highly segmented scintillator
The highly sensitive method to search for WIMPs dark matter particles is
proposed. An array of thin NaI(Tl) plate has the great selectivity for
distinguishing the WIMPs events and background ones. The principle of signal
selection for WIMPs is described. The high sensitivity for SD (spin-dependent)
type WIMPs is expected by applying multi-layer system of NaI(Tl) detector.Comment: 11 pages, added some sentences to make the arguments clea
Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus -- the "D-shuttle" project --
Twelve high schools in Japan (of which six are in Fukushima Prefecture), four
in France, eight in Poland and two in Belarus cooperated in the measurement and
comparison of individual external doses in 2014. In total 216 high-school
students and teachers participated in the study. Each participant wore an
electronic personal dosimeter "D-shuttle" for two weeks, and kept a journal of
his/her whereabouts and activities. The distributions of annual external doses
estimated for each region overlap with each other, demonstrating that the
personal external individual doses in locations where residence is currently
allowed in Fukushima Prefecture and in Belarus are well within the range of
estimated annual doses due to the background radiation level of other
regions/countries