28 research outputs found

    The performance of thin NaI(Tl) scintillator plate for dark matter search

    Full text link
    A thin (0.05cm) and wide area (5cmX5cm) NaI(Tl) scintillator was developed. The performance of the thin NaI(Tl) plate, energy resolution, single photoelectron energy and position sensitivity were tested. An excellent energy resolution of 20% (FWHM) at 60keV was obtained. The single photoelectron energy was calculated to be approximately 0.42 0.02keV. Position information in the 5cmx5cm area of the detector was also obtained by analyzing the ratio of the number of photons collected at opposite ends of the detector. The position resolution was obtained to be 1cm (FWHM) in the 5cmx5cm area.Comment: 10 pages. Accepted to Journal of Physical Society of Japa

    WIMPs search by means of the highly segmented scintillator

    Full text link
    The highly sensitive method to search for WIMPs dark matter particles is proposed. An array of thin NaI(Tl) plate has the great selectivity for distinguishing the WIMPs events and background ones. The principle of signal selection for WIMPs is described. The high sensitivity for SD (spin-dependent) type WIMPs is expected by applying multi-layer system of NaI(Tl) detector.Comment: 11 pages, added some sentences to make the arguments clea

    Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus -- the "D-shuttle" project --

    Full text link
    Twelve high schools in Japan (of which six are in Fukushima Prefecture), four in France, eight in Poland and two in Belarus cooperated in the measurement and comparison of individual external doses in 2014. In total 216 high-school students and teachers participated in the study. Each participant wore an electronic personal dosimeter "D-shuttle" for two weeks, and kept a journal of his/her whereabouts and activities. The distributions of annual external doses estimated for each region overlap with each other, demonstrating that the personal external individual doses in locations where residence is currently allowed in Fukushima Prefecture and in Belarus are well within the range of estimated annual doses due to the background radiation level of other regions/countries

    A study of the He(p, ) He reaction close to threshold

    No full text
    SIGLEAvailable from CEN Saclay, Service de Documentation, 91191 Gif-sur-Yvette Cedex (France) / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc
    corecore