57 research outputs found

    Implementing Ac-225 labelled radiopharmaceuticals:practical considerations and (pre-)clinical perspectives

    Get PDF
    BackgroundIn the past years, there has been a notable increase in interest regarding targeted alpha therapy using Ac-225, driven by the observed promising clinical anti-tumor effects. As the production and technology has advanced, the availability of Ac-225 is expected to increase in the near future, making the treatment available to patients worldwide.Main bodyAc-225 can be labelled to different biological vectors, whereby the success of developing a radiopharmaceutical depends heavily on the labelling conditions, purity of the radionuclide source, chelator, and type of quenchers used to avoid radiolysis. Multiple (methodological) challenges need to be overcome when working with Ac-225; as alpha-emission detection is time consuming and highly geometry dependent, a gamma co-emission is used, but has to be in equilibrium with the mother-nuclide. Because of the high impact of alpha emitters in vivo it is highly recommended to cross-calibrate the Ac-225 measurements for used quality control (QC) techniques (radio-TLC, HPLC, HP-Ge detector, and gamma counter). More strict health physics regulations apply, as Ac-225 has a high toxicity, thereby limiting practical handling and quantities used for QC analysis.ConclusionThis overview focuses specifically on the practical and methodological challenges when working with Ac-225 labelled radiopharmaceuticals, and underlines the required infrastructure and (detection) methods for the (pre-)clinical application

    Integrated Data Analysis of Six Clinical Studies Points Toward Model-Informed Precision Dosing of Tamoxifen

    Get PDF
    Introduction: At tamoxifen standard dosing, ∼20% of breast cancer patients do not reach proposed target endoxifen concentrations >5.97 ng/mL. Thus, better understanding the large interindividual variability in tamoxifen pharmacokinetics (PK) is crucial. By applying non-linear mixed-effects (NLME) modeling to a pooled ‘real-world’ clinical PK database, we aimed to (i) dissect several levels of variability and identify factors predictive for endoxifen exposure and (ii) assess different tamoxifen dosing strategies for their potential to increase the number of patients reaching target endoxifen concentrations. Methods: Tamoxifen and endoxifen concentrations with genetic and demographic data of 468 breast cancer patients from six reported studies were used to develop a NLME parent-metabolite PK model. Different levels of variability on model parameters or measurements were investigated and the impact of covariates thereupon explored. The model was subsequently applied in a simulation-based comparison of three dosing strategies with increasing degree of dose individualization for a large virtual breast cancer population. Interindividual variability of endoxifen concentrations and the fraction of patients at risk for not reaching target concentrations were assessed for each dosing strategy. Results and Conclusions: The integrated NLME model enabled to differentiate and quantify four levels of variability (interstudy, interindividual, interoccasion, and intraindividual). Strong influential factors, i.e., CYP2D6 activity score, drug–drug interactions with CYP3A and CYP2D6 inducers/inhibitors and age, were reliably identified, reducing interoccasion variability to <20% CV. Yet, unexplained interindividual variability in endoxifen formation remained large (47.2% CV). Hence, therapeutic drug monitoring seems promising for achieving endoxifen target concentrations. Three tamoxifen dosing strategies [standard dosing (20 mg QD), CYP2D6-guided dosing (20, 40, and 60 mg QD) and individual model-informed precision dosing (MIPD)] using three therapeutic drug monitoring samples (5–120 mg QD) were compared, leveraging the model. The proportion of patients at risk for not reaching target concentrations was 22.2% in standard dosing, 16.0% in CYP2D6-guided dosing and 7.19% in MIPD. While in CYP2D6-guided- and standard dosing interindividual variability in endoxifen concentrations was high (64.0% CV and 68.1% CV, respectively), it was considerably reduced in MIPD (24.0% CV). Hence, MIPD demonstrated to be the most promising strategy for achieving target endoxifen concentrations

    Clinical implications of food-drug interactions with small-molecule kinase inhibitors

    Get PDF
    During the past two decades, small-molecule kinase inhibitors have proven to be valuable in the treatment of solid and haematological tumours. However, because of their oral administration, the intrapatient and interpatient exposure to small-molecule kinase inhibitors (SMKIs) is highly variable and is affected by many factors, such as concomitant use of food and herbs. Food-drug interactions are capable of altering the systemic bioavailability and pharmacokinetics of these drugs. The most important mechanisms underlying food-drug interactions are gastrointestinal drug absorption and hepatic metabolism through cytochrome P450 isoenzymes. As food-drug interactions can lead to therapy failure or severe toxicity, knowledge of these interactions is essential. This Review provides a comprehensive overview of published studies involving food-drug interactions and herb-drug interactions for all registered SMKIs up to Oct 1, 2019. We critically discuss US Food and Drug Administration (FDA) and European Medicines Agency (EMA) guidelines concerning food-drug interactions and offer clear recommendations for their management in clinical practice

    Early Identification of Patients at Risk of Cabazitaxel-induced Severe Neutropenia

    Get PDF
    BACKGROUND: Cabazitaxel frequently causes severe neutropenia. A higher cabazitaxel systemic exposure is related to a lower nadir absolute neutrophil count (ANC).OBJECTIVE: To describe the effect of cabazitaxel systemic exposure on ANC by a population pharmacokinetic/pharmacodynamic (POP-PK/PD) model, and to identify patients at risk of severe neutropenia early in their treatment course using a PK threshold.DESIGN, SETTING, AND PARTICIPANTS: Data from five clinical studies were pooled to develop a POP-PK/PD model using NONMEM, linking both patient characteristics and cabazitaxel systemic exposure directly to ANC.OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: A PK threshold, predictive of severe neutropenia (grade ≥3), was determined using a receiver operating characteristic curve.RESULTS AND LIMITATIONS: Ninety-six patients were included with a total of 1726 PK samples and 1081 ANCs. The POP-PK/PD model described both cabazitaxel PK and ANC accurately. A cabazitaxel plasma concentration of &gt;4.96 ng/ml at 6 h after the start of infusion was found to be predictive of severe neutropenia, with a sensitivity of 76% and a specificity of 65%.CONCLUSIONS: Early cabazitaxel plasma levels are predictive of severe neutropenia. Implementation of the proposed PK threshold results in early identification of almost 76% of all severe neutropenias. If prospectively validated, patients at risk could benefit from prophylactic administration of granulocyte colony stimulating factors, preventing severe neutropenia in an early phase of treatment. Implementation of this threshold permits a less restricted use of the 25 mg/m2 dose, potentially increasing the therapeutic benefit.PATIENT SUMMARY: Treatment with cabazitaxel chemotherapy often causes neutropenia, leading to susceptibility to infections, which might be life threatening. We found that a systemic cabazitaxel concentration above 4.96 ng/ml 6 h after the start of infusion is predictive of the occurrence of severe neutropenia. Measurement of systemic cabazitaxel levels provides clinicians with the opportunity to prophylactically stimulate neutrophil growth.</p

    Therapeutic Drug Monitoring of Kinase Inhibitors in Oncology

    Get PDF
    Although kinase inhibitors (KI) frequently portray large interpatient variability, a 'one size fits all' regimen is still often used. In the meantime, relationships between exposure-response and exposure-toxicity have been established for several KIs, so this regimen could lead to unnecessary toxicity and suboptimal efficacy. Dose adjustments based on measured systemic pharmacokinetic levels-i.e., therapeutic drug monitoring (TDM)-could therefore improve treatment efficacy and reduce the incidence of toxicities. Therefore, the aim of this comprehensive review is to give an overview of the available evidence for TDM for the 77 FDA/EMA kinase inhibitors currently approved (as of July 1st, 2023) used in hematology and oncology. We elaborate on exposure-response and exposure-toxicity relationships for these kinase inhibitors and provide practical recommendations for TDM and discuss corresponding pharmacokinetic targets when possible

    Obesity Alters Endoxifen Plasma Levels in Young Breast Cancer Patients: A Pharmacometric Simulation Approach

    Get PDF
    Endoxifen is the most important metabolite of the prodrug tamoxifen. High interindividual variability in endoxifen steady-state concentrations (CSS,min ENDX) is observed under tamoxifen standard dosing breast cancer patients that do not reach endoxifen concentrations above a proposed therapeutic threshold of 5.97 ng/mL may be at higher recurrence risk. In this investigation, 10 clinical tamoxifen studies were pooled (nPatients=1388) to investigate influential factors on CSS,min ENDX using nonlinear mixed-effects modelling. Age and body weight were found to significantly impact CSS,min ENDX in addition to CYP2D6 phenotype. Compared to post-menopausal patients, pre-menopausal patients had a 30% higher risk for subtarget CSS,min ENDX at tamoxifen 20 mg per day. In treatment simulations for distinct patient subpopulations, young overweight patients had a 3.1-13.8-fold higher risk for subtarget CSS,min ENDX compared to elderly low-weight patients. Considering ever-rising obesity rates and the clinical importance of tamoxifen for pre-menopausal patients, this subpopulation may benefit most from individualised tamoxifen dosing

    Influence of germline variations in drug transporters ABCB1 and ABCG2 on intracerebral osimertinib efficacy in patients with non-small cell lung cancer

    Get PDF
    BACKGROUND: Central nervous system (CNS) metastases are present in approximately 40% of patients with metastatic epidermal growth factor receptor-mutated ( EGFRm+) non-small cell lung cancer (NSCLC). The EGFR-tyrosine kinase inhibitor osimertinib is a substrate of transporters ABCB1 and ABCG2 and metabolized by CYP3A4. We investigated relationships between single nucleotide polymorphisms (SNPs) ABCB1 3435C>T, ABCG2 421C>A and 34G>A, and CYP3A4∗22 and CNS treatment efficacy of osimertinib in EGFRm+ NSCLC patients. METHODS: Patients who started treatment with osimertinib for EGFRm+ NSCLC between November 2014 and June 2021 were included in this retrospective observational multicentre cohort study. For patients with baseline CNS metastases, the primary endpoint was CNS progression-free survival (CNS-PFS; time from osimertinib start until CNS disease progression or death). For patients with no or unknown baseline CNS metastases, the primary endpoint was CNS disease-free survival (CNS-DFS; time from osimertinib start until occurrence of new CNS metastases). Relationships between SNPs and baseline characteristics with CNS-PFS and CNS-DFS were studied with competing-risks survival analysis. Secondary endpoints were relationships between SNPs and PFS, overall survival, severe toxicity, and osimertinib pharmacokinetics. FINDINGS: From 572 included patients, 201 had baseline CNS metastases. No SNP was associated with CNS-PFS. Genotype ABCG2 34GA/AA and/or ABCB1 3435CC --present in 35% of patients-- was significantly associated with decreased CNS-DFS (hazard ratio 0.28; 95% CI 0.11-0.73; p = 0.009) in the multivariate analysis. This remained significant after applying a Bonferroni correction and internal validation through bootstrapping. ABCG2 421CA/AA was related to more severe toxicity (27.0% versus 16.5%; p = 0.010). INTERPRETATION: ABCG2 34G>A and ABCB1 3435C>T are predictors for developing new CNS metastases during osimertinib treatment, probably because of diminished drug levels in the CNS. ABCG2 421C>A was significantly related with the incidence of severe toxicity. Pre-emptive genotyping for these SNPs could individualize osimertinib therapy. Addition of ABCG2 inhibitors for patients without ABCG2 34G>A should be studied further, to prevent new CNS metastases during osimertinib treatment. FUNDING: No funding was received for this trial

    Implementing Ac-225 labelled radiopharmaceuticals: practical considerations and (pre-)clinical perspectives

    Get PDF
    Abstract Background In the past years, there has been a notable increase in interest regarding targeted alpha therapy using Ac-225, driven by the observed promising clinical anti-tumor effects. As the production and technology has advanced, the availability of Ac-225 is expected to increase in the near future, making the treatment available to patients worldwide. Main body Ac-225 can be labelled to different biological vectors, whereby the success of developing a radiopharmaceutical depends heavily on the labelling conditions, purity of the radionuclide source, chelator, and type of quenchers used to avoid radiolysis. Multiple (methodological) challenges need to be overcome when working with Ac-225; as alpha-emission detection is time consuming and highly geometry dependent, a gamma co-emission is used, but has to be in equilibrium with the mother-nuclide. Because of the high impact of alpha emitters in vivo it is highly recommended to cross-calibrate the Ac-225 measurements for used quality control (QC) techniques (radio-TLC, HPLC, HP-Ge detector, and gamma counter). More strict health physics regulations apply, as Ac-225 has a high toxicity, thereby limiting practical handling and quantities used for QC analysis. Conclusion This overview focuses specifically on the practical and methodological challenges when working with Ac-225 labelled radiopharmaceuticals, and underlines the required infrastructure and (detection) methods for the (pre-)clinical application

    Pharmacokinetics of dalteparin during haemodialysis

    No full text
    BACKGROUND/AIMS: Usually, the appropriate dosage of low-molecular-weight heparin during haemodialysis is empirically based on the clinical effect. We studied the pharmacokinetics of dalteparin during standard haemodialysis in different groups of patients to assess the added value of measuring the anti-Xa activity for dose monitoring and adjustments.METHODS:The pharmacokinetics of intravenously administered dalteparin during haemodialysis was studied in 9 patients during 27 haemodialysis sessions. Six patients received a single bolus dose of dalteparin (group 1), and 3 patients received a higher initial bolus dose of dalteparin followed by a second bolus dose after 2 h (group 2). The clinical effect was evaluated by visual inspection for clot formation in the extracorporeal circuit.RESULTS:The pharmacokinetic curve suggests a zero-order process of elimination. The mean decrease in anti-Xa activity (slope) was comparable in all patients. The mean anti-Xa activity at the end of haemodialysis (Clast) was 0.15 IU/ml in group 1 and 0.60 IU/ml in group 2.CONCLUSION:We conclude that measuring anti-Xa activity can be used to monitor the elimination of dalteparin during haemodialysis and is highly reproducible.</p
    • …
    corecore