80 research outputs found

    Improving the efficiency of the cardiac catheterization laboratories through understanding the stochastic behavior of the scheduled procedures

    Get PDF
      Background: In this study, we sought to analyze the stochastic behavior of Catherization Labora­tories (Cath Labs) procedures in our institution. Statistical models may help to improve estimated case durations to support management in the cost-effective use of expensive surgical resources. Methods: We retrospectively analyzed all the procedures performed in the Cath Labs in 2012. The duration of procedures is strictly positive (larger than zero) and has mostly a large mini­mum duration. Because of the strictly positive character of the Cath Lab procedures, a fit of a lognormal model may be desirable. Having a minimum duration requires an estimate of the threshold (shift) parameter of the lognormal model. Therefore, the 3-parameter lognormal model is interesting. To avoid heterogeneous groups of observations, we tested every group-car­diologist-procedure combination for the normal, 2- and 3-parameter lognormal distribution. Results: The total number of elective and emergency procedures performed was 6,393 (8,186 h). The final analysis included 6,135 procedures (7,779 h). Electrophysiology (intervention) pro­cedures fit the 3-parameter lognormal model 86.1% (80.1%). Using Friedman test statistics, we conclude that the 3-parameter lognormal model is superior to the 2-parameter lognormal model. Furthermore, the 2-parameter lognormal is superior to the normal model. Conclusions: Cath Lab procedures are well-modelled by lognormal models. This information helps to improve and to refine Cath Lab schedules and hence their efficient use.

    Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease

    Get PDF
    BACKGROUND: Excimer laser coronary angioplasty is reported to give excellent procedural results for treatment of complex coronary lesions, but this method has not been compared with balloon angioplasty in a randomised trial. METHODS: Patients (n = 308) with stable angina and coronary lesions longer than 10 mm on visual assessment were included. 151 patients (158 lesions) were assigned randomly to laser angioplasty and 157 (167 lesions) to balloon angioplasty. The primary clinical endpoints were death, myocardial infarction, coronary bypass surgery, or repeat coronary angioplasty of the randomised segment during 6 months of follow-up. The primary angiographic endpoint was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by quantitative coronary angiography. FINDINGS: Laser angioplasty was followed by balloon angioplasty in 98% of procedures. The angiographic success rate was 80% in patients treated with laser angioplasty compared with 79% in patients treated with balloon angioplasty. There were no deaths. Myocardial infarction, coronary bypass surgery, and repeat angioplasty occurred in 4.6%, 10.6%, and 21.2%, respectively, of the patients in the laser angioplasty group compared with 5.7%, 10.8%, and 18.5% of the balloon angioplasty group. Net mean (SD) gain in minimal lumen diameter was 0.40 (0.69) mm in patients treated with laser angioplasty and 0.48 (0.66) mm in those treated with balloon angioplasty (p = 0.34). The restenosis rate (> 50% diameter stenosis) was 51.6% in the laser angioplasty group versus 41.3% in the balloon angioplasty group (p = 0.13). INTERPRETATION: Excimer laser angioplasty followed by balloon angioplasty provides no benefit additional to balloon angioplasty alone with respect to the initial and long-term clinical and angiographic outcome in the treatment of obstructive coronary artery diseas

    Value of bronchoscopy after EUS in the preoperative assessment of patients with esophageal cancer at or above the carina

    Get PDF
    Introduction: Esophageal cancer is an aggressive disease with a strong tendency to infiltrate into surrounding structures. The aim of the present study is to determine the additional value of bronchoscopy for detecting invasion of the tracheobronchial tree after endoscopic ultrasonography (EUS) in the preoperative assessment of patients with esophageal cancer at or above the carina. Materials and Methods: Between January 1997 and December 2006, 104 patients were analyzed for histologically proven esophageal cancer at or above the carina. All patients underwent both EUS and bronchoscopy (with biopsy on indication) in the preoperative assessment of local resectability. Results and Discussion: After extensive diagnostic workup, 58 of 104 patients (56%) were eligible for potentially curative esophagectomy; nine of these 58 patients (9/58, 15%) appeared to be incurable peroperatively because of ingrowth in the tracheobronchial tree (five patients), ingrowth in other vital structures (two patients) or distant metastases (two patients). Of the 46 non-operable patients, local irresectability (T-stage 4) was identified in 26 patients (26/46, 57%) due to invasion of vital structures on EUS: invasion of the aorta in six patients, invasion of the lung in 11 patients; in 12 patients invasion of the tracheobronchial tree was described, which was confirmed by bronchoscopy in only five patients. No patients with T4 were identified by bronchoscopy alone. Conclusion: For patients with esophageal tumors at or above the carina, no additional value of bronchoscopy (with biopsy on indication) to exclude invasion of the tracheobronchial tree was seen after EUS in a specialized centre. Although based on relatively small numbers, we conclude that bronchoscopy is not indicated if no invasion of the airways is identified on EUS

    Rationale and design of EXPLORE: a randomized, prospective, multicenter trial investigating the impact of recanalization of a chronic total occlusion on left ventricular function in patients after primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the setting of primary percutaneous coronary intervention, patients with a chronic total occlusion in a non-infarct related artery were recently identified as a high-risk subgroup. It is unclear whether ST-elevation myocardial infarction patients with a chronic total occlusion in a non-infarct related artery should undergo additional percutaneous coronary intervention of the chronic total occlusion on top of optimal medical therapy shortly after primary percutaneous coronary intervention. Possible beneficial effects include reduction in adverse left ventricular remodeling and preservation of global left ventricular function and improved clinical outcome during future coronary events.</p> <p>Methods/Design</p> <p>The Evaluating Xience V and left ventricular function in Percutaneous coronary intervention on occLusiOns afteR ST-Elevation myocardial infarction (EXPLORE) trial is a randomized, prospective, multicenter, two-arm trial with blinded evaluation of endpoints. Three hundred patients after primary percutaneous coronary intervention for ST-elevation myocardial infarction with a chronic total occlusion in a non-infarct related artery are randomized to either elective percutaneous coronary intervention of the chronic total occlusion within seven days or standard medical treatment. When assigned to the invasive arm, an everolimus-eluting coronary stent is used. Primary endpoints are left ventricular ejection fraction and left ventricular end-diastolic volume assessed by cardiac Magnetic Resonance Imaging at four months. Clinical follow-up will continue until five years.</p> <p>Discussion</p> <p>The ongoing EXPLORE trial is the first randomized clinical trial powered to investigate whether recanalization of a chronic total occlusion in a non-infarct related artery after primary percutaneous coronary intervention for ST-elevation myocardial infarction results in a better preserved residual left ventricular ejection fraction, reduced end-diastolic volume and enhanced clinical outcome.</p> <p>Trial registration</p> <p>trialregister.nl NTR1108.</p

    Coronary pressure never lies

    No full text
    Fractional Flow Reserve (FFR), calculated by coronary pressure measurement, is the invasive gold standard to assess the hemodynamic significance of a coronary stenosis. FFR reliably indicates whether a stenosis is responsible for inducible ischemia and if percutaneous coronary intervention is appropriate. False positive or negative FFR is rare. Occasionally, however, a clinical or angiographic condition is encountered in which in first instance the FFR measurement contradicts the intuitive feeling of the interventionalist. Further examination in such cases, however, often reveals a clear physiologic explanation and in this manner FFR "lifts the veil". Two such patients are presented in this case report and the reasons for apparent or actual false positive or negative FFR are discussed

    Improving the efficiency of the cardiac catheterization laboratories through understanding the stochastic behavior of the scheduled procedures

    No full text
    \u3cp\u3eBACKGROUND: In this study, we sought to analyze the stochastic behavior of Catherization Laboratories (Cath Labs) procedures in our institution. Statistical models may help to improve estimated case durations to support management in the cost-effective use of expensive surgical resources.\u3c/p\u3e\u3cp\u3eMETHODS: We retrospectively analyzed all the procedures performed in the Cath Labs in 2012. The duration of procedures is strictly positive (larger than zero) and has mostly a large minimum duration. Because of the strictly positive character of the Cath Lab procedures, a fit of a lognormal model may be desirable. Having a minimum duration requires an estimate of the threshold (shift) parameter of the lognormal model. Therefore, the 3-parameter lognormal model is interesting. To avoid heterogeneous groups of observations, we tested every group-cardiologist-procedure combination for the normal, 2- and 3-parameter lognormal distribution.\u3c/p\u3e\u3cp\u3eRESULTS: The total number of elective and emergency procedures performed was 6,393 (8,186 h). The final analysis included 6,135 procedures (7,779 h). Electrophysiology (intervention) procedures fit the 3-parameter lognormal model 86.1% (80.1%). Using Friedman test statistics, we conclude that the 3-parameter lognormal model is superior to the 2-parameter lognormal model. Furthermore, the 2-parameter lognormal is superior to the normal model.\u3c/p\u3e\u3cp\u3eCONCLUSIONS: Cath Lab procedures are well-modelled by lognormal models. This information helps to improve and to refine Cath Lab schedules and hence their efficient use.\u3c/p\u3

    Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment

    No full text
    \u3cp\u3eBackground - Although intravascular ultrasound (IVUS) is the present standard for the evaluation of optimum stent deployment, this technique is expensive and not routinely feasible in most catheterization laboratories. Coronary pressure-derived myocardial fractional flow reserve (FFR(myo)) is an easy, cheap, and rapidly obtainable index that is specific for the conductance of the epicardial coronary artery. In this study, we investigated the usefulness of coronary pressure measurement to predict optimum and suboptimum stent deployment. Methods and Results - In 30 patients, a Wiktor- i stent was implanted at different inflation pressures, starting at 6 atm and increasing step by step to 8, 10, 12, and 14 atm, if necessary. After every step, stent deployment was evaluated by quantitative coronary angiography (QCA), IVUS, and coronary pressure measurement. If any of the 3 techniques did not yield an optimum result, the next inflation was performed, and all 3 investigational modalities were repeated until optimum stent deployment was present by all of them or until the treating physician decided to accept the result. Optimum deployment according to QCA was finally achieved in 24 patients, according to IVUS in 17 patients, and also according to coronary pressure measurement in 17 patients. During the step-up, a total of 81 paired IVUS and coronary pressure measurements were performed, of which 91% yielded concordant results (ie, either an optimum or a suboptimum expansion of the stent by both techniques, P&lt;0.00001). On the contrary, QCA showed a low concordance rate with IVUS and FFR(myo) (48% and 46%, respectively). Conclusions - In this study, using a coil stent, both IVUS and coronary pressure measurement were of similar value with respect to the assessment of optimum stent deployment. Therefore, coronary pressure measurement can be used as a cheap and rapid alternative to IVUS for that purpose.\u3c/p\u3
    corecore