18 research outputs found

    Towards a rational design of faecal transplant analogues

    Get PDF
    Faecal transplants (microbiota transfer) have shown to be promising therapies having a wide range of therapeutic applications. However, current safety considerations hamper further valorisation. As such, well designed faecal transplant analogues provide an interesting alternative to minimize possible safety aspects. However, to date little knowledge on how to rationally design such analogues exists. Here, we show by applying first order basic graph theory that such analogues dedicated to restoring a specific physiological functionality (a microbial guild) should consist of 5–6 species to maximize stability, efficiency, and minimize safety issues and production costs

    Maternal Lifestyle Impairs Embryonic Growth

    Get PDF
    Previously, embryonic growth has been assumed to be uniform, but in recent years, it has become more clear that genetic and environmental factors may influence the intrauterine environment and therefore embryonic growth trajectories as well as pregnancy course and outcome. The objective of this study was to investigate associations between modifiable maternal nutrition and lifestyle factors during the periconception period and embryonic growth. We established a prospective cohort including 342 women less than 13 weeks pregnant. At enrollment, women filled out a questionnaire regarding demographic and medical data and a validated food frequency questionnaire. Participants received multiple 3-dimensional ultrasound examinations up until the 12th week of pregnancy, and crown–rump length (CRL) and embryonic volume (EV) were measured offline using V-Scope Virtual Reality software (version 1.0.0) in a Barco I-Space. Associations between maternal periconception vegetable and fruit intake, folic acid supplement use, smoking, and alcohol consumption and embryonic growth measurements were assessed by linear mixed models adjusted for potential confounders. No or postconception initiation of folic acid supplement use was significantly associated with a 0.76 mm (−7.8%) and 1.63 mm (−3.7%) smaller CRL and a 0.01 cm3 (−19.5%) and 0.86 cm3 (−12.2%) smaller EV at 7+0 and 11+0 weeks of gestation, respectively. Smoking, alcohol consumption, and inadequate fruit and vegetable intake showed weaker associations with embryonic growth parameters. These results emphasize the influence of periconceptional maternal folic acid supplement use on embryonic growth. Results regarding maternal nutrition and lifestyle factors also suggest an association with embryonic growth, but this has to be confirmed in a larger study

    First-Trimester Crown-Rump Length and Embryonic Volume of Fetuses with Structural Congenital Abnormalities Measured in Virtual Reality

    Get PDF
    Background With the introduction of three-dimensional (3D) ultrasound it has become possible to measure volumes. The relative increase in embryonic volume (EV) is much larger than that of the crown-rump length (CRL) over the same time period. We examined whether EV is a better parameter to determine growth restriction in fetuses with structural congenital abnormalities. Study Design, Subjects, and Outcome Measures CRL and EV were measured using a Virtual Reality (VR) system in prospectively collected 3D ultrasound volumes of 56 fetuses diagnosed with structural congenital abnormalities in the first trimester of pregnancy (gestational age 7+5 to 14+5 weeks). Measured CRL and EV were converted to z-scores and to percentages of the expected mean using previously published reference curves of euploid fetuses. The one-sample t-test was performed to test significance. Results The EV was smaller than expected for GA in fetuses with structural congenital abnormalities (-35% p<0.001, z-score -1.44 p<0.001), whereas CRL was not (-6.43% p=0.118, z-score -0.43 p=0.605). Conclusions CRL is a less reliable parameter to determine growth restriction in fetuses with structural congenital abnormalities as compared with EV. By measuring EV, growth restriction in first-trimester fetuses with structural congenital abnormalities becomes more evident and enables an earlier detection of these cases

    Breast and Tumour Volume Measurements in Breast Cancer Patients Using 3-D Automated Breast Volume Scanner Images

    Get PDF
    Background: The resection volume in relation to the breast volume is known to influence cosmetic outcome following breast-conserving therapy. It was hypothesised that three-dimensional ultrasonography (3-D US) could be used to preoperatively assess breast and tumour volume and show high association with histopathological measurements. Methods: Breast volume by the 3D-US was compared to the water displacement method (WDM), mastectomy specimen weight, 3-D MRI and three different calculations for breast volume on mammography. Tumour volume by the 3-D US was compared to the histopathological tumour volume and 3-D MRI. Relatedness was based on the intraclass correlation coefficient (ICC) with corresponding 95% confidence interval (95% CI). Bland–Altman plots were used to graphically display the agreement for the different assessment techniques. All measurements were performed by one observer. Results: A total of 36 patients were included, 20 and 23 for the evaluation of breast and tumour volume (ductal invasive carcinomas), respectively. 3-D US breast volume showed ‘excellent’ association with WDM, ICC 0.92 [95% CI (0.80–0.97)]. 3-D US tumour volume showed a ‘excellent’ association with histopathological tumour volume, ICC 0.78 [95% CI (0.55–0.91)]. Bland–Altman plots showed an increased overestimation in lager tumour volumes measured by 3-D MRI compared to histopathological volume. Conclusions: 3-D US showed a high association with gold standard WDM for the preoperative assessment of breast volume and the histopathological measurement of tumour volume. 3-D US is an patient-friendly preoperative available technique to calculate both breast volume and tumour volume. Volume measurements are promising in outcome prediction of intended breast-conserving treatment

    Larger First-Trimester Placental Volumetric Parameters Are Associated With Lower Pressure and More Flow-Mediated Vasodilation of the Fetoplacental Vasculature After Delivery

    Get PDF
    Objective: To explore the correlation between in vivo placental volumetric parameters in the first trimester of pregnancy and ex vivo parameters of fetoplacental vascular function after delivery. Methods: In ten singleton physiological pregnancies, placental volume (PV) and uteroplacental vascular volume (uPVV) were measured offline in three-dimensional ultrasound volumes at 7, 9, and 11 weeks gestational age (GA) using Virtual Organ Analysis and Virtual Reality. Directly postpartum, term placentas were ex vivo dually perfused and pressure in the fetoplacental vasculature was measured to calculate baseline pressure (pressure after a washout period), pressure increase (pressure after a stepwise fetal flow rate increase of 1 mL/min up to 6 mL/min) and flow-mediated vasodilation (FMVD; reduction in inflow hydrostatic pressure on the fetal side at 6 mL/min flow rate). Correlations between in vivo and ex vivo parameters were assessed by Spearman’s correlation coefficients (R). Results: Throu

    Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect

    Get PDF
    Background. This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D) echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD). Methods. 12 data sets from intraoperative epicardial echocardiographic studies in 5 operations (patient age at operation 3 weeks to 4 years and bodyweight at operation 3.8 to 17.2 kg) after surgical closure of VSD were included in the study. The data sets were analysed as two-dimensional (2D) images on the screen of the ultrasound system as well as holograms in an I-space virtual reality (VR) system. The 2D images were assessed for tricuspid valve function. In the I-Space, a 6 degrees-of-freedom controller was used to create the necessary projectory positions and cutting planes in the hologram. The holograms were used for additional assessment of tricuspid valve leaflet mobility. Results. All data sets could be used for 2D as well as holographic analysis. In all data sets the area of interest could be identified. The 2D analysis showed no tricuspid valve stenosis or regurgitation. Leaflet mobility was considered normal. In the virtual reality of the I-Space, all data sets allowed to assess the tricuspid leaflet level in a single holographic representation. In 3 holograms the septal leaflet showed restricted mobility that was not appreciated in the 2D echocardiogram. In 4 data sets the posterior leaflet and the tricuspid papillary apparatus were not completely included. Conclusion. This report shows that dynamic holographic imaging of intraoperative postoperative echocardiographic data regarding tricuspid valve function after VSD closure is feasible. Holographic analysis allows for additional tricuspid valve leaflet mobility analysis. The large size of the probe, in relation to small size of the patient, may preclude a complete data set. At the moment the requirement of an I-Space VR system limits the applicability in virtual reality 3D echocardiography in clinical practice

    First trimester anomaly scan using virtual reality (VR FETUS study): study protocol for a randomized clinical trial

    Get PDF
    BACKGROUND: In recent years it has become clear that fetal anomalies can already be detected at the end of the first trimester of pregnancy by two-dimensional (2D) ultrasound. This is why increasingly in developed countries the first trimester anomaly scan is being offered as part of standard care. We have developed a Virtual Reality (VR) approach to improve the diagnostic abilities of 2D ultrasound. Three-dimensional (3D) ultrasound datasets are used in VR assessment, enabling real depth perception and unique interaction. The aim of this study is to investigate whether first trimester 3D VR ultrasound is of additional value in terms of diagnostic accuracy for the detection of fetal anomalies. Health-related quality of life, cost-effectiveness and also the perspective of both patient and ultrasonographer on the 3D VR modality will be studied. METHODS: Women in the first trimester of a high risk pregnancy for a fetus with a congenital anomaly are eligible for inclusion. This is a randomized controlled trial with two intervention arms. The control group receives 'care as usual': a second trimester 2D advanced ultrasound examination. The intervention group will undergo an additional first trimester 2D and 3D VR ultrasound examination. Following each examination participants will fill in validated questionnaires evaluating their quality of life and healthcare related expenses. Participants' and ultrasonographers' perspectives on the 3D VR ultrasound will be surveyed. The primary outcom

    TUmor-volume to breast-volume RAtio for improving COSmetic results in breast cancer patients (TURACOS); a randomized controlled trial

    Get PDF
    Background: Cosmetic result following breast conserving surgery (BCS) for cancer influences quality of life and psychosocial functioning in breast cancer patients. A preoperative prediction of expected cosmetic result following BCS is not (yet) standard clinical practice and therefore the choice for either mastectomy or BCS is still subjective. Recently, we showed that tumour volume to breast volume ratio as well as tumour location in the breast are independent predictors of superior cosmetic result following BCS. Implementation of a prediction model including both factors, has not been studied in a prospective manner. This study aims to improve cosmetic outcome by implementation of a prediction model in the treatment decision making for breast cancer patients opting for BCS. Methods/design: Multicentre, single-blinded, randomized controlled trial comparing standard preoperative work-up to a preoperative work-up with addition of the prediction model. Tumour volume to bre

    Evaluation of First-Trimester Physiological Midgut Herniation Using Three-Dimensional Ultrasound

    Get PDF
    Introduction: The aim of this study was to investigate the development of midgut herniation in vivo using three-dimensional (3D) ultrasonographic volume and distance measurements and to create reference data for physiological midgut herniation in ongoing pregnancies in a tertiary hospital population. Materials and Methods: The transvaginal 3D ultrasound volumes of 112 women, seen weekly during the first trimester of pregnancy, were obtained and subsequently analysed in a virtual reality environment. The width of the umbilical cord insertion, the maximum diameter of the umbilical cord, and the volume of midgut herniation were measured from 6 until 13 weeks gestational age (GA). Results: All parameters had a positive relation with GA, crown-rump length, and abdominal circumference. In approximately 1 of 10 volumes no midgut herniation could be observed at 9 and 10 weeks GA. In 5.0% of the fetuses the presence of midgut herniation could still be visualised at 12 weeks GA. Conclusion: Reference charts for several dimensions of physiological midgut herniation were created. In the future, our data might be used as a reference in the first trimester for comparison in case of a suspected pathological omphalocele

    Evaluation of embryonic posture using four-dimensional ultrasound and virtual reality

    Get PDF
    Aim: To assess the possibility of embryonic posture evaluation (=feasibility, reproducibility, variation) at rest at 9 weeks' (+0–6 days) gestational age (GA) using four-dimensional ultrasound and virtual reality (VR) techniques. Moreover, it is hypothesized that embryonic posture shows variation at the same time point in an uneventful pregnancy. Methods: In this explorative prospective cohort study, 23 pregnant women were recruited from the Rotterdam periconceptional cohort. A transvaginal four-dimensional ultrasound examination of 30 min per pregnancy was performed between 9 and 10 weeks' GA. The acquired datasets were offline evaluated longitudinally (i.e. per frame) using VR techniques. Results: The ultrasound data of 16 (70%) out of 23 pregnancies were eligible for evaluation. At rest the analysis of the embryonic posture was feasible and showed a strong (>80%) intraobserver and interobserver reproducibility for most body parts. The majority of the body parts were in similar anatomic positions at rest. However, variations in anatomic positions
    corecore