15 research outputs found

    First experiences with an adjustable gravitational valve in childhood hydrocephalus

    No full text

    Management of a locked Strata valve

    No full text

    The use of abdominal binders to treat over-shunting headaches

    No full text

    Magnetic field interactions in adjustable hydrocephalus shunts

    No full text

    Frameless Image-Guided Neuroendoscopy Training in Real Simulators

    No full text
    Background: Over the last decade, neuroendoscopy has re-emerged as an interesting option in the management of intraventricular lesions in both children and adults. Nonetheless, as it has become more difficult to use cadaveric specimens in training, the development of alternative methods was vital. the aim of this study was to analyze the performance of a real simulator, in association with image-guided navigation, as a teaching tool for the training of intraventricular endoscopic procedures.Methods: 3 real simulators were built using a special type of resin. 1 was designed to represent the abnormally enlarged ventricles, making it possible for a third ventriculostomy to be performed. the remaining 2 were designed to simulate a person's skull and brain bearing intraventricular lesions, which were placed as follows: in the foramen of Monro region, in the frontal and occipital horns of the lateral ventricles and within the third ventricle. in all models, MRI images were obtained for navigation guidance. Within the ventricles, the relevant anatomic structures and the lesions were identified through the endoscope and compared with the position given by the navigation device. the next step consisted of manipulating the lesions, using standard endoscopic techniques.Results: We observed that the models were MRI compatible, easy and safe to handle. They nicely reproduced the intraventricular anatomy and brain consistence, as well as simulated intraventricular lesions. the image-based navigation was efficient in guiding the surgeon through the endoscopic procedure, allowing the selection of the best approach as well as defining the relevant surgical landmarks for each ventricular compartment. Nonetheless, as expected, navigation inaccuracies occurred. After the training sessions the surgeons felt they had gained valued experience by dealing with intraventricular lesions employing endoscopic techniques.Conclusion: the use of real simulators in association with image-guided navigation proved to be an effective tool in training for neuroendoscopy.Universidade Federal de São Paulo, Paulista Sch Med, Dept Neurol & Neurosurg, BR-04037001 São Paulo, BrazilNeurologia Inst Curitiba, Dept Neurosurg, Curitiba, Parana, BrazilUniv Fed Pernambuco, Dept Gynecol, Recife, PE, BrazilUniversidade Federal de São Paulo, Paulista Sch Med, Dept Neurol & Neurosurg, BR-04037001 São Paulo, BrazilWeb of Scienc
    corecore