25 research outputs found

    Strategies for improvement of population based breast cancer screening

    Get PDF

    CBCT-based navigation system for open liver surgery: accurate guidance toward mobile and deformable targets with a semi-rigid organ approximation and electromagnetic tracking of the liver

    Get PDF
    Purpose The surgical navigation system that provides guidance throughout the surgery can facilitate safer and more radical liver resections, but such a system should also be able to handle organ motion. This work investigates the accuracy of intraoperative surgical guidance during open liver resection, with a semi-rigid organ approximation and electromagnetic tracking of the target area.Methods The suggested navigation technique incorporates a preoperative 3D liver model based on diagnostic 4D MRI scan, intraoperative contrast-enhanced CBCT imaging and electromagnetic (EM) tracking of the liver surface, as well as surgical instruments, by means of six degrees-of-freedom micro-EM sensors.Results The system was evaluated during surgeries with 35 patients and resulted in an accurate and intuitive real-time visualization of liver anatomy and tumor's location, confirmed by intraoperative checks on visible anatomical landmarks. Based on accuracy measurements verified by intraoperative CBCT, the system's average accuracy was 4.0 +/- 3.0 mm, while the total surgical delay due to navigation stayed below 20 min.Conclusions The electromagnetic navigation system for open liver surgery developed in this work allows for accurate localization of liver lesions and critical anatomical structures surrounding the resection area, even when the liver was manipulated. However, further clinically integrating the method requires shortening the guidance-related surgical delay, which can be achieved by shifting to faster intraoperative imaging like ultrasound. Our approach is adaptable to navigation on other mobile and deformable organs, and therefore may benefit various clinical applications.Radiolog

    Imaging in interventional oncology, the better you see, the better you treat

    Get PDF
    Imaging and image processing is the fundamental pillar of interventional oncology in which diagnostic, procedure planning, treatment and follow-up are sustained. Knowing all the possibilities that the different image modalities can offer is capital to select the most appropriate and accurate guidance for interventional procedures. Despite there is a wide variability in physicians preferences and availability of the different image modalities to guide interventional procedures, it is important to recognize the advantages and limitations for each of them. In this review, we aim to provide an overview of the most frequently used image guidance modalities for interventional procedures and its typical and future applications including angiography, computed tomography (CT) and spectral CT, magnetic resonance imaging, Ultrasound and the use of hybrid systems. Finally, we resume the possible role of artificial intelligence related to image in patient selection, treatment and follow-up.Patholog

    Adjuvant Hepatic Arterial Infusion Pump Chemotherapy After Resection of Colorectal Liver Metastases: Results of a Safety and Feasibility Study in The Netherlands

    Get PDF
    Background: The 10-year overall survival with adjuvant hepatic arterial infusion pump (HAIP) chemotherapy after resection of colorectal liver metastases (CRLMs) was 61% in clinical trials from Memorial Sloan Kettering Cancer Center. A pilot study was performed to evaluate the safety and feasibility of adjuvant HAIP chemotherapy in patients with resectable CRLMs. Study Design: A phase II study was performed in two centers in The Netherlands. Patients with resectable CRLM without extrahepatic disease were eligible. All patients underwent complete resection and/or ablation of CRLMs and pump implantation. Safety was determined by the 90-day HAIP-related postoperative complications from the day of pump placement (Clavien–Dindo classification, grade III or higher) and feasibility by the successful administration of the first cycle of HAIP chemotherapy. Results: A total of 20 patients, with a median age of 57 years (interquartile range [IQR] 51–64) were included. Grade III or higher HAIP-related postoperative complications were found in two patients (10%), both of whom had a reoperation (without laparotomy) to replace a pump with a slow flow rate or to reposition a flipped pump. No arterial bleeding, arterial dissection, arterial thrombosis, extrahepatic perfusion, pump pocket hematoma, or pump pocket infections were found within 90 days after surgery. After a median of 43 days (IQR 29–52) following surgery, all patients received the first dose of HAIP chemotherapy, which was completed un

    Adjuvant hepatic arterial infusion pump chemotherapy and resection versus resection alone in patients with low-risk resectable colorectal liver metastases - the multicenter randomized controlled PUMP trial

    Get PDF
    Background Recurrences are reported in 70% of all patients after resection of colorectal liver metastases (CRLM), in which half are confined to the liver. Adjuvant hepatic arterial infusion pump (HAIP) chemotherapy aims to reduce the risk of intrahepatic recurrence. A large retrospective propensity score analysis demonstrated that HAIP chemotherapy is particularly effective in patients with low-risk oncological features. The aim of this randomized controlled trial (RCT) --the PUMP trial-- is to investigate the efficacy of adjuvant HAIP chemotherapy in low-risk patients with resectable CRLM. Methods This is an open label multicenter RCT. A total of 230 patients with resectable CRLM without extrahepatic disease will be included. Only patients with a clinical risk score (CRS) of 0 to 2 are eligible, meaning: patients are allowed to have no more than two out of five poor prognostic factors (disease-free interval less than 12 months, node-positive colorectal cancer, more than 1 CRLM, largest CRLM more than 5 cm in diameter, serum Carcinoembryonic Antigen above 200 μg/L). Patients randomized to arm A undergo complete resection of CRLM without any adjuvant treatment, which is the standard of care in the Netherlands. Patients in arm B receive an implantable pump at the time of CRLM resection and start adjuvant HAIP chemotherapy 4–12 weeks after surgery, with 6 cycles of floxuridine scheduled. The primary endpoint is progression-free survival (PFS). Secondary endpoints include overall survival, hepatic PFS, safety, quality of life, and cost-effectiveness. Pharmacokinetics of intra-arterial administration of floxuridine will be investigated as well as predictive biomarkers for the efficacy of HAIP chemotherapy. In a side study, the accuracy of CT angiography will be compared to radionuclide scintigraphy to detect extrahepatic perfusion. We hypothesize that adjuvant HAIP chemotherapy leads to improved survival, improved quality of life, and

    Treatment of temporal artery pseudoaneurysms

    No full text
    Purpose: To give an overview of the etiology and diagnostic process of superficial temporal artery pseudoaneurysms and to evaluate different treatment modalities. Basic methods: PubMed was used for searching multiple databases for relevant clinical studies. Principal findings: A total of 62 studies were included, harboring 82 patients. Surgical excision is the most frequently described treatment, but less invasive treatment modalities as coiling and thrombin injections are gaining popularity. Surgical treatment was successful in all cases (67/67). Endovascular treatment was successful in 69% (9/13); the five cases treated with thrombin injection were all successful. Complementary, a description of our experience with thrombin injection is given. Conclusions: Limited evidence of minimal invasive treatment for superficial temporal artery pseudoaneurysm is available. Based on this review combined with our limited experience, we suggest thrombin injections to be considered as the future primary treatment modality. In the case of unsuccessful exclusion of the aneurysm, surgical excision can be performed

    Axillary reverse mapping (ARM) in clinically node positive breast cancer patients

    No full text
    Background: Axillary reverse mapping (ARM) is a technique to map and preserve upper extremity lymphatic drainage during axillary lymph node dissection (ALND) in breast cancer patients. We prospectively evaluated the metastatic involvement of ARM-nodes in patients who underwent an ALND for clinically node positive disease following (neo)adjuvant chemotherapy (NAC) in comparison to patients in whom primary ALND was performed without NAC. Patients and methods: Patients with clinically node positive invasive breast cancer, confirmed by fine needle aspiration cytology and scheduled for primary ALND were enrolled in the study: Patients were separated into two groups: one group treated with NAC (NAC+ group) and one group not treated with NAC (NAC- group). ARM was performed in all patients by injecting blue dye into the ipsilateral upper extremity. During ALND, ARM-nodes were first identified and removed separately, followed by a standard ALND. Results: 91 patients were included in the NAC+ and 21 patients in the NAC- group. There was no difference in the ARM visualization rate between the two groups (86.8% for NAC+ group versus 90.5% for NAC- group, P = 0.647). In the NAC+ group 16.5% of the patients had metastatic involvement of the ARM-nodes versus 36.8% of the patients in the NAC- group (P = 0.048). Conclusion: The risk of metastatic involvement of ARM-nodes in clinically node positive breast cancer patients is significantly lower in patients who have received NAC. (C) 2014 Elsevier Ltd. All rights reserved

    Comparison of the diagnostic workup of women referred at non-blinded or blinded double reading in a population-based screening mammography programme in the south of the Netherlands

    No full text
    Background: To determine whether referred women experience differences in diagnostic workup at non-blinded or blinded double reading of screening mammograms. Methods: We included a consecutive series of respectively 42.996 and 44.491 screens, double read either in a non-blinded or blinded manner between 2009 and 2011. This reading strategy was alternated on a monthly basis. Results: The overall ultrasound-guided core needle biopsy (CNB) rate and stereotactic CNB (SCNB) rate per 1000 screens were higher at blinded than at non-blinded reading (7.5 vs 6.0, P = 0.008 and 8.1 vs 6.6, P = 0.009). Among women with benign workup, these rates were higher at blinded reading (2.6 vs 1.4, P <0.001 and 5.9 vs 4.7, P = 0.013). The benign biopsy rates were higher at blinded double reading (P <0.001), whereas the positive predictive value of biopsy did not differ (P = 0.103). Conclusions: Blinded double-reading results in higher overall CNB and SCNB rates than non-blinded double reading, as well as a higher benign biopsy rate

    Editor's Choice - Use of Disposable Radiation-absorbing Surgical Drapes Results in Significant Dose Reduction During EVAR Procedures

    Get PDF
    ObjectivesBecause of the increasing number of interventional endovascular procedures with fluoroscopy and the corresponding high annual dose for interventionalists, additional dose-protecting measures are desirable. The purpose of this study was to evaluate the effect of disposable radiation-absorbing surgical drapes in reducing scatter radiation exposure for interventionalists and supporting staff during an endovascular aneurysm repair (EVAR) procedure.MaterialsThis was a randomized control trial in which 36 EVAR procedures were randomized between execution with and without disposable radiation-absorbing surgical drapes (Radpad: Worldwide Innovations & Technologies, Inc., Kansas City, US, type 5511A). Dosimetric measurements were performed on the interventionalist (hand and chest) and theatre nurse (chest) with and without the use of the drapes to obtain the dose reduction and effect on the annual dose caused by the drapes.ResultsUse of disposable radiation-absorbing surgical drapes resulted in dose reductions of 49%, 55%, and 48%, respectively, measured on the hand and chest of the interventionalist and the chest of the theatre nurse.ConclusionsThe use of disposable radiation-absorbing surgical drapes significantly reduces scatter radiation exposure for both the interventionalist and the supporting staff during EVAR procedures
    corecore