4 research outputs found

    Development of a detector based on a CVD-diamond for the use in radiotherapy facilities

    No full text
    High radiation hardness, chemical resistance, high temperature operation capabilities stimulate a growing interest to use diamond materials as detectors of ionizing radiation. Samples of CVD-diamond materials in sizes 4×3 mm and 4×1 mm with thickness from 50 microns up to 500 microns have been grown in INR RAS using a DC glow discharge in a mixture of gases CH4/H2 on molybdenum substrates.Высокая радиационная стойкость, стойкость к химическим воздействиям, температурная стабильность вызывают повышенный интерес к использованию алмазных материалов в качестве детекторов ионизирующих излучений. Образцы CVD-алмазных материалов размерами 4×3 и 4×1 мм толщиной от 50 до 500 мкм выращены в ИЯИ РАН методом газофазного осаждения в тлеющем разряде в смеси газов СН4/Н2 на подложках из молибдена.Висока радіаційна стійкість, стійкість до хімічних впливів, температурна стабільність викликають підвищений інтерес до використання алмазних матеріалів як детектори іонізуючих випромінювань. Зразки CVD-алмазних матеріалів розмірами 4×3 та 4×1 мм товщиною від 50 до 500 мкм вирощені в ІЯІ РАН методом газофазного осадження в жевріючому розряді в суміші газів СН4/Н2 на підкладках з молібдену

    Operation of the 400-750kV pulse voltage multi-cascade discriminator

    No full text
    The multi-cascade discriminator (МD) of the amplitude of pulsed 400-750kV voltage is an important part of the pulse high-voltage generator at the highcurrent linac injector of the Moscow meson factory [1]. It was invented and designed at the Efremov Institute of Electrophysical Apparature (Leningrad). It was partially tested at the factory [2] and successfully ran at 1 Hz repetition rate [3] in the adjusting mode of the accelerator. However the transition to 50Hz repetition rate gave rise to certain drawbacks, such as the current overloading of the inductivities, breakdown of the diodes and insufficient voltage. Analytical and experimental researches were conducted, and the required changes were made on their basis. These changes allowed the discriminator to operate with high reliability. The main results are set forth in this report

    H⁻ injector for Moscow meson factory linac

    No full text
    Status report is presented for an H⁻ injector being now under construction. The injector parameters are as follows: energy − 400 keV; average beam current − 400 µA; beam pulse duration − up to 200 µs; pulse repetition rate − 50 Hz. A pulsed high-voltage generator and a surface-plasma ion source power supply have been developed and manufactured.Представлено состоянии работ по созданию инжектора отрицательных ионов водорода с энергией 400 кВ, который должен обеспечить средний ток пучка ионов до 400 мкА при длительности импульса тока до 200 мкс и частоте повторения импульсов 50 Гц. Разработаны, изготовлены и смонтированы генератор ускоряющего импульсного напряжения и система питания поверхностно-плазменного ионного источника.Представлено звіт про стан робіт зі створення інжектора негативних іонів водню з енергією 400 кВ, що повинен забезпечити середній струм пучка іонів до 400 мкА при тривалості імпульсу струму пучка до 200 мкс і частоті повторення імпульсів 50 Гц. Розроблено, виготовлені і змонтовані генератор прискорювальної імпульсної напруги і система живлення поверхнево-плазмового іонного джерел

    Nuclear Incoherence: Deterrence Theory and Non-Strategic Nuclear Weapons in Russia

    No full text
    corecore