52 research outputs found

    A paperfluidic platform to detect Neisseria gonorrhoeae in clinical samples

    Full text link
    Globally, the microbe Neisseria gonorrhoeae (NG) causes 106 million newly documented sexually transmitted infections each year. Once appropriately diagnosed, NG infections can be readily treated with antibiotics, but high-risk patients often do not return to the clinic for treatment if results are not provided at the point of care. A rapid, sensitive molecular diagnostic would help increase NG treatment and reduce the prevalence of this sexually transmitted disease. Here, we report on the design and development of a rapid, highly sensitive, paperfluidic device for point-of-care diagnosis of NG. The device integrates patient swab sample lysis, nucleic acid extraction, thermophilic helicase-dependent amplification (tHDA), an internal amplification control (NGIC), and visual lateral flow detection within an 80 min run time. Limits of NG detection for the NG/NGIC multiplex tHDA assay were determined within the device, and clinical performance was validated retroactively against qPCR-quantified patient samples in a proof-of-concept study. This paperfluidic diagnostic has a clinically relevant limit of detection of 500 NG cells per device with analytical sensitivity down to 10 NG cells per device. In triplicate testing of 40 total urethral and vaginal swab samples, the device had 95% overall sensitivity and 100% specificity, approaching current laboratory-based molecular NG diagnostics. This diagnostic platform could increase access to accurate NG diagnoses to those most in need.This work was funded by the National Institute of Health National Institute of Allergy and Infectious Diseases award number R01 AI113927 to Boston University and the NIH National Institute of Biomedical and Bioengineering award number U54 EB007958 to Johns Hopkins University. (R01 AI113927 - National Institute of Health National Institute of Allergy and Infectious Diseases; U54 EB007958 - NIH National Institute of Biomedical and Bioengineering)Accepted manuscrip

    Point-of-Care Sexually Transmitted Infection Diagnostics: Proceedings of the STAR Sexually Transmitted Infection-Clinical Trial Group Programmatic Meeting.

    Get PDF
    The goal of the point-of-care (POC) sexually transmitted infection (STI) Diagnostics meeting was to review the state-of-the-art research and develop recommendations for the use of POC STI diagnostics. Experts from academia, government, nonprofit, and industry discussed POC diagnostics for STIs such as Chlamydia trachomatis, human papillomavirus, Neisseria gonorrhoeae, Trichomonas vaginalis, and Treponema pallidum. Key objectives included a review of current and emerging technologies, clinical and public health benefits, POC STI diagnostics in developing countries, regulatory considerations, and future areas of development. Key points of the meeting are as follows: (i) although some rapid point-of-care tests are affordable, sensitive, specific, easy to perform, and deliverable to those who need them for select sexually transmitted infections, implementation barriers exist at the device, patient, provider, and health system levels; (ii) further investment in research and development of point-of-care tests for sexually transmitted infections is needed, and new technologies can be used to improve diagnostic testing, test uptake, and treatment; (iii) efficient deployment of self-testing in supervised (ie, pharmacies, clinics, and so on) and/or unsupervised (ie, home, offices, and so on) settings could facilitate more screening and diagnosis that will reduce the burden of sexually transmitted infections; (iv) development of novel diagnostic technologies has outpaced the generation of guidance tools and documents issued by regulatory agencies; and (v) questions regarding quality management are emerging including the mechanism by which poor-performing diagnostics are removed from the market and quality assurance of self-testing is ensured

    Microfluidic Chip for Molecular Amplification of Influenza A RNA in Human Respiratory Specimens

    Get PDF
    A rapid, low cost, accurate point-of-care (POC) device to detect influenza virus is needed for effective treatment and control of both seasonal and pandemic strains. We developed a single-use microfluidic chip that integrates solid phase extraction (SPE) and molecular amplification via a reverse transcription polymerase chain reaction (RT-PCR) to amplify influenza virus type A RNA. We demonstrated the ability of the chip to amplify influenza A RNA in human nasopharyngeal aspirate (NPA) and nasopharyngeal swab (NPS) specimens collected at two clinical sites from 2008–2010. The microfluidic test was dramatically more sensitive than two currently used rapid immunoassays and had high specificity that was essentially equivalent to the rapid assays and direct fluorescent antigen (DFA) testing. We report 96% (CI 89%,99%) sensitivity and 100% (CI 95%,100%) specificity compared to conventional (bench top) RT-PCR based on the testing of n = 146 specimens (positive predictive value = 100%(CI 94%,100%) and negative predictive value = 96%(CI 88%,98%)). These results compare well with DFA performed on samples taken during the same time period (98% (CI 91%,100%) sensitivity and 96%(CI 86%,99%) specificity compared to our gold standard testing). Rapid immunoassay tests on samples taken during the enrollment period were less reliable (49%(CI 38%,61%) sensitivity and 98%(CI 98%,100%) specificity). The microfluidic test extracted and amplified influenza A RNA directly from clinical specimens with viral loads down to 103 copies/ml in 3 h or less. The new test represents a major improvement over viral culture in terms of turn around time, over rapid immunoassay tests in terms of sensitivity, and over bench top RT-PCR and DFA in terms of ease of use and portability

    Developmental patterns of sleep slow wave activity and synaptic density in adolescent mice.

    No full text
    STUDY OBJECTIVE: In humans sleep slow wave activity (SWA) declines during adolescence. It has been suggested that this decline reflects the elimination of cortical synapses, but this hypothesis has never been tested directly. DESIGN: We focused on mouse frontal cortex and collected data from early adolescence (∼postnatal day 20, P20) to adulthood (P60) of (1) SWA; (2) expression of synapsin I, a presynaptic marker; and (3) number of dendritic spines in layers I-II. SETTING: Basic sleep research laboratory. PATIENTS OR PARTICIPANTS: YFP-line H mice (n = 70; P15-87, all males) and GFP-line S mice (n = 14; P17-60, 8 females) were used for EEG recording. Forty-five YFP mice (P19-119, 12 females) and 42 GFP-S mice (P20-60, 14 females) were used for in vivo 2-photon imaging and ex vivo confocal microscopy, respectively. Other YGP mice (n = 57, P10-77) were used for western blot analysis of synapsin I. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: As in humans, SWA in mice declined from early adolescence to adulthood. Synapsin I levels increased from P10 to P24, with little change afterwards. Mean spine density in apical dendrites of layer V pyramidal neurons (YFP-H) showed no change from P20 to P60. Spine number in layers I-II apical dendrites, belonging to layer III and V pyramidal neurons (GFP-S), increased slightly from P20 to P30 and decreased from P30 to P60; smaller spines decreased in number from P20 to P60, while bigger spines increased. CONCLUSIONS: In mice, it is unlikely that the developmental decrease in SWA can be accounted for by a net pruning of cortical synapses
    • …