    Electro-magnetic Tooling for Metal Forming and Powder Compaction

    Get PDF
    The multipurpose FE Code ANSYS is employed to simulate an electro-magnetic forming process. A complicated compression coil with a ferromagnetic outer screen and a stepped field shaper is considered. Details on FE model building are thoroughly discussed. The calculated parameters are the magnetic flux density around the conductors as well as the Lorentz forces developed in both the field shaper and the workpiece. A simplified analysis of the workpiece deformation characteristics is also provided. An equivalent circuit method is employed in order to validate the results from the electro-magnetic FE model. Results from both analyses are in good agreement, denoting that the FE results are valid from an engineering point of view

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    Get PDF
    Abstract Background This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p Conclusions In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH

    Wind turbine control strategy enabling mechanical stress reduction based on dynamic model including blade oscillation effects

    No full text

    A hybrid maximum power point tracking system for grid-connected variable speed wind-generators

    No full text
    • …