206 research outputs found

    The reiterative accuracy of gait determined by simplified gait analysis

    Get PDF
    Dynamic perception is the perception of the relation of moving body parts to each other. To examine dynamic perception, the reiterative accuracy of well-known movements - for example, gait - is analysed. Simplified gait analysis can be obtained for 50 cycles of gait in this research. The high number of gait cycles analysed provides an opportunity to calculate the average and standard deviation of different temporal (duration of stance phase, swing phase, double support phase) and spatial parameters (step length, stride length, cadence) of each subject investigated. 45 healthy, young subjects, 11 professional hand ball players, 24 patients after medial meniscectomy, 20 elderly, healthy subjects, and 20 patients with hip osteoarthritis are investigated. The average, standard deviation and normalized deviation of parameters of each person are calculated. The normalized deviation of parameters enables modelling of dynamic perception, because it is independent from the value of parameters due to normalization. O ur tests show that the size of the parameter is independent from lateral dominance at healthy subjects. The size of the normalized deviation of parameters depends on age, on the intensity of sports activities, and on orthopaedical diseases

    Verification of determining the spatial position of the lower extremity by ultrasound-based motion analyser

    Get PDF
    The objective of this study is to verify the ultrasound-based motion analysis method on 16 healthy people during gait. Ultrasound-based triplets were fixed onto the sacrum, the left and right thighs and the left and right calves. A ZEBRIS ultrasound-based motion analysis system was used for measuring the spatial coordinates of triplets during gait. The position of the nineteen anatomical points involved in the study was defined by an ultrasound-based pointer in the local coordinate system specified by the triplets before starting measurements. The spatial coordinates of the designated anatomical points can be calculated from the coordinate of triplets. The method is calibrated with interobserver and intraobserver variations. On the basis of the statistical analysis of the spatial coordinates specified by the ultrasound-based measurement method, it can be established that the measurement method is reproducible because in case of an experienced person performing measurements the maximum standard deviation of co ordinates is below 1 mm, and around 2 mm in case of a person inexperienced in measurements

    Verification of determining the curvatures and range of motion of the spine by electromechanical-based skin-surface device

    Get PDF
    There is an increasing awareness of the risk and dangers of exposure to radiation associated with repeated radiographic assessment of spinal curvature and spinal movement. As such, attempts are continuously being made to develop skin surface devices for use in examining the progression and response to treatment of various spinal disorders. However, devices must be verified before use in research or in a clinical environment. The aim of this study was to examine the reliability of measurements using a skin-surface device, the Spinal Mouse on 30 healthy volunteers. Spinal curvature was measured with the Spinal Mouse during standing, flexion, and extension (each five times by each of two examiners). The method was calibrated by a ZEBRIS ultrasound-based measuring method with WINSPINE software commercially available, and the measurement error rate of the method was determined by statistical calculations. On the basis of calibration and error calculations it could be established that the accuracy and the reproduci bility of the method were appropriate, because the maximum value of intraobserver variation is 0.97 degrees (18.8%), that of interobserver variation is 1.54 degrees (27.1%). A second way of verifying the method is to specify the difference between the angles determined by the two methods. The maximum value of the average difference is 1.62 degrees (26.6%)

    KINEMATICAL ANALYSIS OF SHOULDER JOINT DURING ELEVATION MEASURED BY ULTRASOUND-BASED MEASURING SYSTEM

    Get PDF
    In order to analyse shoulder joint movements, the author uses a ZEBRIS CMS-HS ultrasound-based movement sensor and a related measurement program developed by the researchers in Biomechanical Laboratory in TUB. In essence, the measurement involves the determination of the spatial position of the 16 anatomical points specified on the basis of the coordinates of ultrasound-based triplets positioned on the upper limb, the scapula, and the thorax, measured in the course of motion. Kinematic characteristics of 74 shoulder joints of 50 healthy persons were identified during elevation. A specially developed processing program was used for the calculation and analysis of humerus elevation, scapulothoracal, and glenohumeral angles, defined as angles of spatial vectors; the glenohumeral, scapulothorocal and capuloglenoid ratio to be determined therefrom; and of scapulothoracal and glenohumeral rhythm during motion. Motion of the humerus and the scapula relative to each other was characterized by the rotation center of the two bones and rigid bodies as well as their absolute and relative displacement relative to each other. The biomechanical model of the shoulder joint during elevation can be described by analysing the results of the measurements performed

    Application of OptiTrack motion capture systems in human movement analysis A systematic literature review

    Get PDF
    With the spreading of motion analysis decisions to invest into a new system demand scientific reference applications. The aim of the present systematic review is to reveal the biomechanical scientific applications of OptiTrack motion capture systems and to overview documented usage conditions and purposes. Six major scientific literature databases were used (PubMed, PubMed Central, ScienceDirect, IEEE Xplore, PLOS and Web Of Science). An OptiTrack camera system had to be used for human or biologically related motion capture. A total of 85 articles were included, 4 out of which dealt with the validation of OptiTrack systems and 81 utilized the system for biomechanical analyses. The data analysed and extracted from the system validation studies included: description of the validated and the reference system, measured features and observed errors. The data extracted from the utilizing studies also included: OptiTrack application, camera type and frequency, marker size, camera number, data processing software and the motion studied. The review offers a broad collection of biomechanical applications of OptiTrack motion capture systems as scientific references for certain motion studies. The review also summarizes findings on the accuracy of the systems. It concludes that the method descriptions of system usage are often underspecifie

    Parameter Reduction in the Frequency Analysis of Center of Pressure in Stabilometry

    Get PDF
    During postural stability evaluation frequency analyses are applied on the motion of the foot center of pressure (CoP). In this study we compared the most widely used frequency type CoP parameters (median frequency, mean power frequency, bandwidth) including some newly defined parameters (frequency range power ratios, spectral power ratio between the anteroposterior and mediolateral directions, largest CoP amplitude with the corresponding frequency). The parameters were acquired from 25 young and healthy participants. Correlation analysis was used to exclude parameters that contain redundant information. Variance analysis was used to evaluate the behavior and usability of the parameters in different stance conditions (bipedal stance with eyes open and eyes closed, single leg stance with eyes open) where the balancing capability alters. Based on our results we recommend using the largest amplitude and frequency power ratios between specified frequency bands, spectral power ratio between anteroposterior and mediolateral direction and mean power frequency

    Verification of simplified gait analysis

    Get PDF
    In this study we describe a simplified gait analysis system for the estimation of spatial-temporal parameters and kinetic parameters during walking on an instrumented treadmill. This method proposes to compute the values of temporal (length of double support phase, length of stance phase, time of step, time of stride) and few spatial parameters (step length, stride length, cadence) from the graph of time vs. ground reaction force at a constant gait speed. The method was verified by a clinical gait analysis method using a ZEBRIS ultrasound-based measuring system with ARMMODEL software, and the measurement error rate of the method was determined by statistical calculations. The maximum relative value of the average difference of temporal parameters is 0.79 % in cycle time and that of spatial parameters is 0.66%. On the basis of statistical analysis, it can be established that the measurement method is reproducible. This system is simple, inexpensive and does not provoke any discomfort to subjects. It can be car ried on for long periods of time during a treadmill walk, thus providing new longitudinal information such as the stride-to-stride variability of gait. Several clinical applications can be proposed such as outcome evaluation after different orthopaedical, rheumatological, neurological diseases, and monitoring of the rehabilitation process

    Validation of the Estimated Torques of an Open-chain Kinematic Model of the Human Body

    Get PDF
    The standing human body is frequently modeled as an inverted double pendulum restricted to a single plane. In order to capture the coordination efforts and interplay between spatial dimensions, the model has to capture motion and joint torques in all spatial dimensions. Our two-segment model covers two degrees of freedom (ML and AP revolutions) at the ankle and the hip level and utilizes the Denavit-Hartenberg convention. This work aimed to validate the model's torque estimation on a diverse group of participants (11 women, 22–56 years, 11 men, 22–61 years). The inverse dynamic calculations provide estimated joint torques for a motion capture recorded trial, while standing on a force platform enables the indirect measurement of ankle torques. A 60-second-long visually guided balancing task was recorded and repeated three times. The estimated and the indirectly measured torques were compared, and offset and variance type errors ( normalized RMSE and R2 ) were analyzed. The R2-values were excellent (R2 > 0.90) 64 out of the 66 cases (97%) for AP torques and 58 out of the 66 cases (88%) for ML torques. Normalized RMSE values were dominantly under the 0.35 value with some outliers. RMSE showed no evident connection with age, body height, body mass, or BMI. An open-chain kinematic model with two segments, following the Denavit-Hartenberg convention, is well suited to estimate the control torque traces of the human body during standing balancing and needs only three tracked positions

    A járás sebességének és a csípőízületi arthrosis fokának hatása a járás változékonyságára

    Get PDF
    The gait analysis is an important element of examination of orthopedic and neurology, howeverfew research studied the variability of gait at different gait speeds and at patients with differentdegree of hip osteoarthritis. The research was intended to clarify 1) how the variability ofgait is affected by different controlled speeds, and 2) how the variability of gait is affected by variousdegrees of hip osteoarthrosis. We examined healthy, elderly subject and patients with moderateand severe hip osteoarthritis at three different gait speed. The spatial positions of anatomical points investigated were determined by zebris CMS-HS ultrasound-based motion analysissytem during more than 400 gait cycles, and the coefficient of varience of spatial, temporal andangular parameters are calculated. Our data suggested that the figures describing the varianceof most parameters significantly depended on speed and on degree of osteoarthritis. The dataalso indicated that the most accurate and secure gait patterns were produced at speeds near theself-selected gait speeds; speeds different therefrom reduced the security and accuracy of gait.For comparisons, it is expedient to perform tests at various controlled speeds, with one of thecontrolled speeds not to deviate significantly from the self-selected gait speed of the subject /group of subjects. Hip joint degeneration significantly worsened variance on the affected side,with non-affected joints and the pelvis plays an important role in compensation as shown byincreased flexibility, thereby playing an increased role in the adaptation of step-by-step motions.The two different characterizations of the kinematic variance of the lower limb (variance of spatialand temporal parameters; variance of angular parameters) may display opposing tendencies,but they describe the same change in gait. Based on the results, it can be stated that uponthe appearance and deterioration of osteoarthrosis, particular attention must be paid to theimprovement of gait stability and accuracy by a variety of special exercises.A járás vizsgálata fontos eleme a biomechanikai, ortopédiai, neurológiai vizsgálatoknak, azonban kevés kutatás foglalkozik a járás variációjának vizsgálatával különbözÅ‘ sebesség és különbözÅ‘ fokú csípÅ‘ízületi arthrosis esetén. A kutatás céljai annak tisztázása volt, 1) hogyan befolyásolja a járás variációját a különbözÅ‘ kontrollált sebesség, 2) hogyan befolyásolja a járás variációját a csípÅ‘ízületi ízületi kopás különbözÅ‘ foka. A járásvizsgálatokat idÅ‘s egészséges, valamint kisfokú és nagyfokú arthrosissal rendelkezÅ‘ betegeken végeztük három különbözÅ‘ kontrollált sebességen. Az anatómiai pontok térbeli helyzetét zebris CMS-HS ultrahang-alapú mozgásvizsgáló rendszerrel végeztük, majd számítottuk a távolság-, idÅ‘-, szögjellegű paraméterek variációs tényezÅ‘jét. Az adataink az sugallták, hogy a legtöbb paraméter variációját jellemzÅ‘ értékek szignifikánsan függtek a sebességtÅ‘l, és az arthrosis fokától. Az adatokból az is látszott, hogy a legpontosabb, legbiztonságosabb járás a szabadon választható sebesség környékén alakult ki, az ettÅ‘l eltérÅ‘ sebességek a járás biztonságát, pontosságát csökkentették. Az összehasonlításokhoz célszerű több kontrollált sebességen végezni a vizsgálatokat, amikor az egyik kontrollált sebesség szignifikánsan nem tér el a vizsgált személy /csoport szabadon választott sebességétÅ‘l. A csípÅ‘ízületi degeneráció szignifikánsan rontotta az érintett oldal variációját, és a kompenzációban az ellenoldali ízületek és a medenceöv szerepe jelentÅ‘s, amit a flexibilitás növekedésével és ezáltal a lépésrÅ‘l-lépésre történÅ‘ mozgások adaptálásában való megnövekedett szerepvállalásra utalt. Az alsó végtag kinematikai variációjának két különbözÅ‘ jellemzése (távolság-idÅ‘ paraméterek variációja, valamint a szögjellemzÅ‘ paraméterek variációja) ellentétes tendenciát mutathat, de ez ugyanazt a járás stabilitási változást jellemzi. Az eredmények alapján azt mondhattuk, hogy az arthrosis megjelenésével és rosszabbodásával különös figyelmet kell fordítani az járás biztonságának, pontosságának javítására különbözÅ‘ speciális gyakorlatokkal. DOI: 10.17489/biohun/2009/2/0

    A fejmozgás szerepe az egyensúlyozó képességben

    Get PDF
    Az ember egy instabil rendszer, így egy folyamatosan működÅ‘ szabályozás szükséges a stabilizálásához. Ezt a szabályozó rendszert jellemzi az egyensúlyozó képesség. A kutatás célja a dinamikus egyensúlyozó képesség elemzése hirtelen irányváltoztatás ún. kilökéses tesztek segítségével. Ha az ember állását megzavarjuk, egyensúlyát veszti, a fejen belül a belsÅ‘ fülben a vesztibuláris rendszer továbbítja az agy felé a megfelelÅ‘ jeleket. Jelen kutatásban a fejmozgás szerepét elemeztük, mint egy meghatározó tényezÅ‘t az egyensúlyozó képességben, hiszen itt található a mozgásunk detektálására alkalmas két legfontosabb érzékelÅ‘rendszer (látórendszer, vesztibuláris rendszer). A kutatás célja olyan új paraméterek definiálása, amelyek az emberi egyensúlyozó képességet megfelelÅ‘ megbízhatósággal jellemzik. A mérésben 2 nÅ‘ és 9 férfi vett részt (n=11; átlagos életkor: 22.82±1.72 év; átlagos magasság: 179.42±10.83 cm; átlagos testtömeg: 80.65±19.90 kg). A mérésekben részt vevÅ‘ alanyoknál a beválasztási paraméter az volt, hogy ne rendelkezzenek mozgásrendszerbeli hátrányossággal. A dinamikus egyensúlyozó képességet ún. kilökéses teszttel, 6 különbözÅ‘ testhelyzetben (kétlábas állás nyitott és csukott szemmel 4 és 8 rugós felfüggesztésnél és egylábas állás mindkét lábbal nyitott szemmel 4 rugós felfüggesztésnél) vizsgáltuk egy PosturoMed© (Haider-Bioswing, Weiden, Németország) eszköz segítségével. Az alany fejére markerekkel felszerelt munkavédelmi sisakot rögzítettünk és a platformra markereket helyeztünk, melyek térbeli koordinátáit a BME MOGI Tanszékének Mozgáslaboratóriumában található Optitrack© Motion Capture kamerarendszer (NaturalPoint, Inc. DBA OptiTrack) segítségével rögzítettünk, Motive© (NaturalPoint, Inc. DBA OptiTrack) és MUBMA (MOGI Universal Biomechanical Motion Analyzer) mérésvezérlÅ‘ programokkal. A fejmozgást leíró paraméter megbízhatóságának elemzéséhez a vizsgálatokat 4 alkalommal végeztük el. Minden alkalommal az alanyokat 10-szer mértük le. Az alkalmak között rendben 3, 9 és 3 nap kimaradás volt, hogy rövidtávú és hosszabb távú ismétléses tesztet is elvégezzünk. A koordinátákból 37 paramétert számítottam és értékeltem ki Mathematica (Wolfram©, v11.2) algoritmusokkal. A paramétereket a platformmozgásból, a fejmozgásból és a fej és platform egymáshoz viszonyított mozgásából számítottam. Az eredmények kiértékelése során elemeztem a sikeres/sikertelen mérések arányát, a mérési alkalmak közötti szignifikáns különbségeket, a vizsgált paraméterek korrelációját és megbízhatóságukat a szakirodalomból ismert megbízhatósági együtthatók (ICC, CV, CVCR) számításával az IBM SPSS Statistics 22® program segítségével. A tesztek eredményei alapján a nem megbízható paramétereket kizártam, így 8 (ebbÅ‘l 5 új: PlatXMinmax, PlatXlokmax, PlatXlokmax_T, PlatPathX és PlatPathY) platformmozgásból számított és 2 új (DiffPathX és DiffMin_X) a fej és a platform egymáshoz viszonyított mozgását jellemzÅ‘ paraméter lett megbízható. A paramétereket olyan szempontból is elemeztem, hogy egyes vizsgált testhelyzetek mérési eredményei között melyek mutatnak szignifikáns különbségeket. A megbízhatósági tesztek eredményeibÅ‘l az is megállapítható, hogy a 4 rugós, kétlábas, nyitott és csukott szemes, valamint a 8 rugós, kétlábas, csukott szemes méréseket, több paraméter jellemezte megbízhatóan, mint a többi testhelyzetben történt mérést. Célszerű ezeket a beállításokat alkalmazni, mivel megbízhatóságuk erÅ‘sebb. A 10 megbízhatónak talált paraméter a 11 vizsgált testhelyzet összehasonlítási esetbÅ‘l minimum 6-nál szignifikáns különbséget mutatott. Így kijelenthetÅ‘, hogy ezek a paraméterek az alkalmazott egyensúlyozási technikát és a vizsgált személy egyensúlyozó képességét megbízhatóan jellemzik. Ezekkel a paraméterekkel az emberi egyensúlyozásról egy átfogóbb képet alkothatunk. Megállapítható, hogy a fejmozgásnak meghatározó szerepe van az egyensúlyozó képességben és modellezésére vannak olyan megbízható paraméterek, amelyek a szakirodalomban nem ismertek. Ezeket, az egyensúlyozó képességet új szemszögbÅ‘l jellemzÅ‘ paramétereket érdemes figyelembe venni jövÅ‘beli kutatások során
    • …