90 research outputs found

    Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues

    Get PDF
    Background: Occupational or environmental exposure to asbestos fibres is associated with pleural and parenchymal lung diseases. A histopathologic hallmark of exposure to asbestos is the presence in lung parenchyma of the so-called asbestos bodies. They are the final product of biomineralization processes resulting in deposition of endogenous iron and organic matter (mainly proteins) around the inhaled asbestos fibres. For shedding light on the formation mechanisms of asbestos bodies it is of fundamental importance to characterize at the same length scales not only their structural morphology and chemical composition but also to correlate them to the possible alterations in the local composition of the surrounding tissues. Here we report the first correlative morphological and chemical characterization of untreated paraffinated histological lung tissue samples with asbestos bodies by means of soft X-ray imaging and X-Ray Fluorescence (XRF) microscopy, which reveals new features in the elemental lateral distribution. Results: The X-ray absorption and phase contrast images and the simultaneously monitored XRF maps of tissue samples have revealed the location, distribution and elemental composition of asbestos bodies and associated nanometric structures. The observed specific morphology and differences in the local Si, Fe, O and Mg content provide distinct fingerprints characteristic for the core asbestos fibre and the ferruginous body. The highest Si content is found in the asbestos fibre, while the shell and ferruginous bodies are characterized by strongly increased content of Mg, Fe and O compared to the adjacent tissue. The XRF and SEM-EDX analyses of the extracted asbestos bodies confirmed an enhanced Mg deposition in the organic asbestos coating. Conclusions: The present report demonstrates the potential of the advanced synchrotron-based X-ray imaging and microspectroscopy techniques for studying the response of the lung tissue to the presence of asbestos fibres. The new results obtained by simultaneous structural and chemical analysis of tissue specimen have provided clear evidence that Mg, in addition to Fe, is also involved in the formation mechanisms of asbestos bodies. This is the first important step to further thorough investigations that will shed light on the physiopathological role of Mg in tissue response to the asbestos toxicity

    Optical constants modelling in silicon nitride membrane transiently excited by EUV radiation.

    Get PDF
    We hereby report on a set of transient optical reflectivity and transmissivity measurements performed on silicon nitride thin membranes excited by extreme ultraviolet (EUV) radiation from a free electron laser (FEL). Experimental data were acquired as a function of the membrane thickness, FEL fluence and probe polarization. The time dependence of the refractive index, retrieved using Jones matrix formalism, encodes the dynamics of electron and lattice excitation following the FEL interaction. The observed dynamics are interpreted in the framework of a two temperature model, which permits to extract the relevant time scales and magnitudes of the processes. We also found that in order to explain the experimental data thermo-optical effects and inter-band filling must be phenomenologically added to the model

    Characterization of ultrafast free-electron laser pulses using extreme-ultraviolet transient gratings

    Get PDF
    The characterization of the time structure of ultrafast photon pulses in the extreme-ultraviolet (EUV) and soft X-ray spectral ranges is of high relevance for a number of scientific applications and photon diagnostics. Such measurements can be performed following different strategies and often require large setups and rather high pulse energies. Here, high-quality measurements carried out by exploiting the transient grating process, i.e. a third-order non-linear process sensitive to the time-overlap between two crossed EUV pulses, is reported. From such measurements it is possible to obtain information on both the second-order intensity autocorrelation function and on the coherence length of the pulses. It was found that the pulse energy density needed to carry out such measurements on solid state samples can be as low as a few mJ cm−2. Furthermore, the possibility to control the arrival time of the crossed pulses independently might permit the development of a number of coherent spectroscopies in the EUV and soft X-ray regime, such as, for example, photon echo and two-dimensional spectroscopy

    Towards jitter-free pump-probe measurements at seeded free electron laser facilities

    Get PDF
    X-ray free electron lasers (FEL) coupled with optical lasers have opened unprecedented opportunities for studying ultrafast dynamics in matter. The major challenge in pump-probe experiments using FEL and optical lasers is synchronizing the arrival time of the two pulses. Here we report a technique that benefits from the seeded-FEL scheme and uses the optical seed laser for nearly jitter-free pump-probe experiments. Timing jitter as small as 6 fs has been achieved and confirmed by measurements of FEL-induced transient reflectivity changes of Si3N4 using both collinear and non-collinear geometries. Planned improvements of the experimental set-up are expected to further reduce the timing jitter between the two pulses down to fs level

    Transmission and emission x-ray microscopy: Operation modes, contrast mechanisms and applications

    No full text
    Advances in microscopy techniques based on x-rays have opened unprecedented opportunities in terms of spatial resolution, combined with chemical and morphology sensitivity, to analyze solid, soft and liquid matter. The advent of ultrabright third and fourth generation photon sources and the continuous development of x-ray optics and detectors has pushed the limits of imaging and spectroscopic analysis to structures as small as a few tens of nanometers. Specific interactions of x-rays with matter provide elemental and chemical sensitivity that have made x-ray spectromicroscopy techniques a very attractive tool, complementary to other microscopies, for characterization in all actual research fields. The x-ray penetration power meets the demand to examine samples too thick for electron microscopes implementing 3D imaging and recently also 4D imaging which adds time resolution as well. Implementation of a variety of phase contrast techniques enhances the structural sensitivity, especially for the hard x-ray regime. Implementation of lensless or diffraction imaging helps to enhance the lateral resolution of x-ray imaging to the wavelength dependent diffraction limit. \ua9 2011 IOP Publishing Ltd

    X-ray fluorescence microscopy artefacts in elemental maps of topologically complex samples: Analytical observations, simulation and a map correction method

    No full text
    XRF spectroscopy is among the most widely used non-destructive techniques for elemental analysis. Despite the known angular dependence of X-ray fluorescence (XRF), topological artefacts remain an unresolved issue when using X-ray micro- or nano-probes. In this work we investigate the origin of the artefacts in XRF imaging of topologically complex samples, which are unresolved problems in studies of organic matter due to the limited travel distances of low energy XRF emission from the light elements. In particular we mapped Human Embryonic Kidney (HEK293T) cells. The exemplary results with biological samples, obtained with a soft X-ray scanning microscope installed at a synchrotron facility were used for testing a mathematical model based on detector response simulations, and for proposing an artefact correction method based on directional derivatives. Despite the peculiar and specific application, the methodology can be easily extended to hard X-rays and to set-ups with multi array detector systems when the dimensions of surface reliefs are in the order of the probing beam size
    • …
    corecore