140,527 research outputs found

    Microstructure Controlled Shear Band Pattern Formation and Enhanced Plasticity of Bulk Metallic Glasses Containing in situ Formed Ductile Phase Dendrite Dispersions

    Get PDF
    Results are presented for a ductile metal reinforced bulk metallic glass matrix composite based on glass forming compositions in the Zr-Ti-Cu-Ni-Be system. Primary dendrite growth and solute partitioning in the molten state yields a microstructure consisting of a ductile crystalline Ti-Zr-Nb β phase, with bcc structure, in a Zr-Ti-Nb-Cu-Ni-Be bulk metallic glass matrix. Under unconstrained mechanical loading organized shear band patterns develop throughout the sample. This results in a dramatic increase in the plastic strain to failure, impact resistance, and toughness of the metallic glass

    Large supercooled liquid region and phase separation in the Zr–Ti–Ni–Cu–Be bulk metallic glasses

    Get PDF
    Results of calorimetric, differential thermal analysis, and structural measurements are presented for a series of bulk metallic glass forming compositions in the Zr-Ti-Cu-Ni-Be alloy system. The calorimetric data for five alloys, prepared along the tie line between phase separating and nonphase separating compositions, show that the transition from phase separating to nonphase separating behavior is smooth. The bulk glasses near the center of the tie line exhibit large supercooled liquid regions: Delta T approximate to 135 K, the largest known for a bulk metallic glass

    Arterial pulse wave pressure transducer

    Get PDF
    An arterial pulse wave pressure transducer is introduced. The transducer is comprised of a fluid filled cavity having a flexible membrane disposed over the cavity and adapted to be placed on the skin over an artery. An arterial pulse wave creates pressure pulses in the fluid which are transduced, by a pressure sensitive transistor in direct contact with the fluid, into an electric signal. The electrical signal is representative of the pulse waves and can be recorded so as to monitor changes in the elasticity of the arterial walls

    An economical arterial-pulse-wave transducer

    Get PDF
    Transducer records arterial pulses externally. Device uses thin plastic membrane which is fluid coupled to pressure sensitive transistor. Transistor is connected to amplifier which, in turn, is connected to recorder. End section is threaded to accept suitable holder and contains pressure relief vent allowing transistor to sense only pressure levels greater than atmospheric
    • …
    corecore