43 research outputs found

    Impaired pulmonary ventilation beyond pneumonia in COVID-19: A preliminary observation

    Get PDF
    BACKGROUND: Coronavirus disease 2019 (COVID-19) may severely impair pulmonary function and cause hypoxia. However, the association of COVID-19 pneumonia on CT with impaired ventilation remains unexplained. This pilot study aims to demonstrate the relationship between the radiological findings on COVID-19 CT images and ventilation abnormalities simulated in a computational model linked to the patients\u27 symptoms. METHODS: Twenty-five patients with COVID-19 and four test-negative healthy controls who underwent a baseline non-enhanced CT scan: 7 dyspneic patients, 9 symptomatic patients without dyspnea, and 9 asymptomatic patients were included. A 2D U-Net-based CT segmentation software was used to quantify radiological futures of COVID-19 pneumonia. The CT image-based full-scale airway network (FAN) flow model was employed to assess regional lung ventilation. Functional and radiological features were compared across groups and correlated with the clinical symptoms. Heterogeneity in ventilation distribution and ventilation defects associated with the pneumonia and the patients\u27 symptoms were assessed. RESULTS: Median percentage ventilation defects were 0.2% for healthy controls, 0.7% for asymptomatic patients, 1.2% for symptomatic patients without dyspnea, and 11.3% for dyspneic patients. The median of percentage pneumonia was 13.2% for dyspneic patients and 0% for the other groups. Ventilation defects preferentially affected the posterior lung and worsened with increasing pneumonia linearly (y = 0.91x + 0.99, R2 = 0.73) except for one of the nine dyspneic patients who had disproportionally large ventilation defects (7.8% of the entire lung) despite mild pneumonia (1.2%). The symptomatic and dyspneic patients showed significantly right-skewed ventilation distributions (symptomatic without dyspnea: 0.86 +/- 0.61, dyspnea 0.91 +/- 0.79) compared to the patients without symptom (0.45 +/- 0.35). The ventilation defect analysis with the FAN model provided a comparable diagnostic accuracy to the percentage pneumonia in identifying dyspneic patients (area under the receiver operating characteristic curve, 0.94 versus 0.96). CONCLUSIONS: COVID-19 pneumonia segmentations from CT scans are accompanied by impaired pulmonary ventilation preferentially in dyspneic patients. Ventilation analysis with CT image-based computational modelling shows it is able to assess functional impairment in COVID-19 and potentially identify one of the aetiologies of hypoxia in patients with COVID-19 pneumonia

    Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide -necked Basilar trunk aneurysm

    Get PDF
    OBJECTIVE: The porous intravascular stents that are currently available may not cause complete aneurysm thrombosis and may therefore fail to provide durable protection against aneurysm rupture when used as a sole treatment modality. The goal of this study was to quantify the effects of porous stents on aneurysm hemodynamics using computational fluid dynamics. METHODS: The geometry of a wide-necked saccular basilar trunk aneurysm was reconstructed from a patient’s computed tomographic angiography images. Three commercial stents (Neuroform2; Boston Scientific/Target, San Leandro, CA; Wingspan; Boston Scientific, Fremont, CA; and Vision; Guidant Corp., Santa Clara, CA) were modeled. Various combinations of one to three stents were virtually conformed to fit into the vessel lumen and placed across the aneurysm orifice. An unstented aneurysm served as a control. Computational fluid dynamics analysis was performed to calculate the hemodynamic parameters considered important in aneurysm pathogenesis and thrombosis for each of the models. RESULTS: The complex flow pattern observed in the unstented aneurysm was suppressed by stenting. Stent placement lowered the wall shear stress in the aneurysm, and this effect was increased by additional stent deployment. Turnover time was moderately increased after single- and double-stent placement and markedly increased after three stents were placed. The influence of stent design on hemodynamic parameters was more significant in double-stented models than in other models. CONCLUSION: Aneurysm hemodynamic parameters were significantly modified by placement of multiple stents. Because the associated modifications may be helpful as well as harmful in terms of rupture risk, use of this technique requires careful consideration

    Comparison of two stents in modifying cerebral aneurysm hemodynamics

    Get PDF
    There is a general lack of quantitative understanding about how specific design features of endovascular stents (struts and mesh design, porosity) affect the hemodynamics in intracranial aneurysms. To shed light on this issue, we studied two commercial high-porosity stents (Tristar stent™ and Wallstent®) in aneurysm models of varying vessel curvature as well as in a patientspecific model using Computational Fluid Dynamics. We investigated how these stents modify hemodynamic parameters such as aneurysmal inflow rate, stasis, and wall shear stress, and how such changes are related to the specific designs. We found that the flow damping effect of stents and resulting aneurysmal stasis and wall shear stress are strongly influenced by stent porosity, strut design, and mesh hole shape. We also confirmed that the damping effect is significantly reduced at higher vessel curvatures, which indicates limited usefulness of high-porosity stents as a stand-alone treatment. Finally, we showed that the stasis-inducing performance of stents in 3D geometries can be predicted from the hydraulic resistance of their flat mesh screens. From this, we propose a methodology to cost-effectively compare different stent designs before running a full 3D simulation

    Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: Implications of intravascular stenting

    Get PDF
    Our aim was to examine hemodynamic implications of intravascular stenting in the canine venous pouch (sidewall or straight-vessel) and rabbit elastase (curved-vessel) aneurysm models. Flow dynamics in stented (Wallstent) and nonstented versions were studied by using computational fluid dynamics simulations and in vitro flow visualization, with a focus on stent placement effects on aneurysmal flow stagnancy and flow impingement. Results show that sidewall and curved aneurysm models have fundamentally different hemodynamics (shear-driven versus inertia-driven) and thus stent placement outcomes

    Validation of CFD simulations of cerebral aneurysms with implication of geometric variations

    Get PDF
    Background. Computational fluid dynamics (CFD) simulations using medical-image-based anatomical vascular geometry are now gaining clinical relevance. This study aimed at validating the CFD methodology for studying cerebral aneurysms by using particle image velocimetry (PIV) measurements, with a focus on the effects of small geometric variations in aneurysm models on the flow dynamics obtained with CFD. Method of Approach. An experimental phantom was fabricated out of silicone elastomer to best mimic a spherical aneurysm model. PIV measurements were obtained from the phantom and compared with the CFD results from an ideal spherical aneurysm model (S1). These measurements were also compared with CFD results, based on the geometry reconstructed from three-dimensional images of the experimental phantom. We further performed CFD analysis on two geometric variations, S2 and S3, of the phantom to investigate the effects of small geometric variations on the aneurysmal flow field. Results. We found poor agreement between the CFD results from the ideal spherical aneurysm model and the PIV measurements from the phantom, including inconsistent secondary flow patterns. The CFD results based on the actual phantom geometry, however, matched well with the PIV measurements. CFD of models S2 and S3 produced qualitatively similar flow fields to that of the phantom but quantitatively significant changes in key hemodynamic parameters such as vorticity, positive circulation, and wall shear stress. Conclusion. CFD simulation results can closely match experimental measurements as long as both are performed on the same model geometry. Small geometric variations on the aneurysm model can significantly alter the flow-field and key hemodynamic parameters. Since medical images are subjected to geometric uncertainties, image-based patient-specific CFD results must be carefully scrutinized before providing clinical feedback

    Computational investigation of prolonged airborne dispersion of novel coronavirus-laden droplets

    Get PDF
    We have performed highly accurate numerical simulations to investigate prolonged dispersion of novel coronavirus-laden droplets in classroom air. Approximately 10,900 virus-laden droplets were released into the air by a teacher coughing and tracked for 90 min by numerical simulations. The teacher was standing in front of multiple students in a classroom. To estimate viral transmission to the students, we considered the features of the novel coronavirus, such as the virus half-life. The simulation results revealed that there was a high risk of prolonged airborne transmission of virus-laden droplets when the outlet flow of the classroom ventilation was low (i.e., 4.3 and 8.6 cm/s). The rates of remaining airborne virus-laden droplets produced by the teacher coughing were 40% and 15% after 45 and 90 min, respectively. The results revealed that students can avoid exposure to the virus-laden droplets by keeping a large distance from the teacher (5.5 m), which is more than two times farther than the currently suggested social distancing rules. The results of this study provide guidelines to set a new protection plan in the classroom to prevent airborne transmission of virus-laden droplets to students

    Numerical model for cough‐generated droplet dispersion on moving escalator with multiple passengers

    Get PDF
    To investigate the motion of virus‐laden droplets between moving passengers in line, we performed numerical simulations of the distribution of airborne droplets within a geometrically detailed model similar to an actual escalator. The left and right sides and the ceiling of the escalator model were surrounded by walls, assuming a subway used by many people every day with concern to virus‐laden droplets. Steps and handrails were incorporated in the model to faithfully compute the escalator‐specific flow field. The ascending and descending movements of the escalator were performed with 10 or 5 passengers standing at different boarding intervals. To resolve the unsteady airflow that is excited by a moving boundary consisting of passengers, steps, and handrails, the moving computational domain method based on the moving‐grid finite‐volume method was applied. On the basis of the consideration that the droplets were small enough, droplet dispersion was computed by solving the equation of virus‐laden droplet motion using a pre‐computed velocity field, in which the flow rate of a cough, diameter distribution, and evaporation of droplets are incorporated. The simulation resolved the detailed motion of droplets in flow, and therefore, we were able to evaluate the risk of viral adhesion to following passengers. As a result, we found that the ascending escalator had a higher risk of being exposed to virus‐laden droplets than the descending escalator. We also reported that the chance of viral droplet adhesion decreases as the distance from the infected person increases, emphasizing the importance of social distancing

    Morphology parameters for intracranial aneurysm rupture risk assessment

    Get PDF
    OBJECTIVE—The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. METHODS—For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P < 0.05) were further examined by multivariate logistic regression analysis. Additionally, receiver operating characteristic analyses were performed on each parameter. RESULTS—Statistically significant differences were found between mean values in ruptured and unruptured groups for size ratio, undulation index, nonsphericity index, ellipticity index, aneurysm angle, and aspect ratio. Logistic regression analysis further revealed that size ratio (odds ratio, 1.41; 95% confidence interval, 1.03−1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08−2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. CONCLUSION—Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies

    Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT

    Get PDF
    Purpose To derive lobar ventilation in patients with chronic obstructive pulmonary disease (COPD) using a rapid time-series hyperpolarized xenon-129 (HPX) magnetic resonance imaging (MRI) technique and compare this to ventilation/perfusion singlephoton emission computed tomography (V/Q-SPECT), correlating the results with high-resolution computed tomography (CT) and pulmonary function tests (PFTs).Materials and methods Twelve COPD subjects (GOLD stages I–IV) participated in this study and underwent HPX-MRI, V/QSPECT/CT, high-resolution CT, and PFTs. HPX-MRI was performed using a novel time-series spiral k-space sampling approach. Relative percentage ventilations were calculated for individual lobe for comparison to the relative SPECT lobar ventilation and perfusion. The absolute HPX-MRI percentage ventilation in each lobe was compared to the absolute CT percentage emphysema score calculated using a signal threshold method. Pearson’s correlation and linear regression tests were performed to compare each imaging modality.Results Strong correlations were found between the relative lobar percentage ventilation with HPX-MRI and percentage ventilation SPECT (r = 0.644; p Conclusion Lobar ventilation with HPX-MRI showed a strong correlation with lobar ventilation and perfusion measurements derived from SPECT/CT, and is better than the emphysema score obtained with high-resolution CT.</div

    Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT

    Get PDF
    PurposeTo derive lobar ventilation in patients with chronic obstructive pulmonary disease (COPD) using a rapid time-series hyperpolarized xenon-129 (HPX) magnetic resonance imaging (MRI) technique and compare this to ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT), correlating the results with high-resolution computed tomography (CT) and pulmonary function tests (PFTs).Materials and methodsTwelve COPD subjects (GOLD stages I–IV) participated in this study and underwent HPX-MRI, V/Q-SPECT/CT, high-resolution CT, and PFTs. HPX-MRI was performed using a novel time-series spiral k-space sampling approach. Relative percentage ventilations were calculated for individual lobe for comparison to the relative SPECT lobar ventilation and perfusion. The absolute HPX-MRI percentage ventilation in each lobe was compared to the absolute CT percentage emphysema score calculated using a signal threshold method. Pearson’s correlation and linear regression tests were performed to compare each imaging modality.ResultsStrong correlations were found between the relative lobar percentage ventilation with HPX-MRI and percentage ventilation SPECT (r = 0.644; p < 0.001) and percentage perfusion SPECT (r = 0.767; p < 0.001). The absolute CT percentage emphysema and HPX percentage ventilation correlation was also statistically significant (r = 0.695, p < 0.001). The whole lung HPX percentage ventilation correlated with the PFT measurements (FEV1 with r = − 0.886, p < 0.001*, and FEV1/FVC with r = − 0.861, p < 0.001*) better than the whole lung CT percentage emphysema score (FEV1 with r = − 0.635, p = 0.027; and FEV1/FVC with r = − 0.652, p = 0.021).ConclusionLobar ventilation with HPX-MRI showed a strong correlation with lobar ventilation and perfusion measurements derived from SPECT/CT, and is better than the emphysema score obtained with high-resolution CT
    corecore