27 research outputs found

    Toward the Restoration of Hand Use to a Paralyzed Monkey: Brain-Controlled Functional Electrical Stimulation of Forearm Muscles

    Get PDF
    Loss of hand use is considered by many spinal cord injury survivors to be the most devastating consequence of their injury. Functional electrical stimulation (FES) of forearm and hand muscles has been used to provide basic, voluntary hand grasp to hundreds of human patients. Current approaches typically grade pre-programmed patterns of muscle activation using simple control signals, such as those derived from residual movement or muscle activity. However, the use of such fixed stimulation patterns limits hand function to the few tasks programmed into the controller. In contrast, we are developing a system that uses neural signals recorded from a multi-electrode array implanted in the motor cortex; this system has the potential to provide independent control of multiple muscles over a broad range of functional tasks. Two monkeys were able to use this cortically controlled FES system to control the contraction of four forearm muscles despite temporary limb paralysis. The amount of wrist force the monkeys were able to produce in a one-dimensional force tracking task was significantly increased. Furthermore, the monkeys were able to control the magnitude and time course of the force with sufficient accuracy to track visually displayed force targets at speeds reduced by only one-third to one-half of normal. Although these results were achieved by controlling only four muscles, there is no fundamental reason why the same methods could not be scaled up to control a larger number of muscles. We believe these results provide an important proof of concept that brain-controlled FES prostheses could ultimately be of great benefit to paralyzed patients with injuries in the mid-cervical spinal cord

    Design and testing of a 96-channel neural interface module for the Networked Neuroprosthesis system

    Full text link
    Abstract Background The loss of motor functions resulting from spinal cord injury can have devastating implications on the quality of one’s life. Functional electrical stimulation has been used to help restore mobility, however, current functional electrical stimulation (FES) systems require residual movements to control stimulation patterns, which may be unintuitive and not useful for individuals with higher level cervical injuries. Brain machine interfaces (BMI) offer a promising approach for controlling such systems; however, they currently still require transcutaneous leads connecting indwelling electrodes to external recording devices. While several wireless BMI systems have been designed, high signal bandwidth requirements limit clinical translation. Case Western Reserve University has developed an implantable, modular FES system, the Networked Neuroprosthesis (NNP), to perform combinations of myoelectric recording and neural stimulation for controlling motor functions. However, currently the existing module capabilities are not sufficient for intracortical recordings. Methods Here we designed and tested a 1 × 4 cm, 96-channel neural recording module prototype to fit within the specifications to mate with the NNP. The neural recording module extracts power between 0.3–1 kHz, instead of transmitting the raw, high bandwidth neural data to decrease power requirements. Results The module consumed 33.6 mW while sampling 96 channels at approximately 2 kSps. We also investigated the relationship between average spiking band power and neural spike rate, which produced a maximum correlation of R = 0.8656 (Monkey N) and R = 0.8023 (Monkey W). Conclusion Our experimental results show that we can record and transmit 96 channels at 2ksps within the power restrictions of the NNP system and successfully communicate over the NNP network. We believe this device can be used as an extension to the NNP to produce a clinically viable, fully implantable, intracortically-controlled FES system and advance the field of bioelectronic medicine.https://deepblue.lib.umich.edu/bitstream/2027.42/147921/1/42234_2019_Article_19.pd

    Treatment of Late Stage Disease in a Model of Arenaviral Hemorrhagic Fever: T-705 Efficacy and Reduced Toxicity Suggests an Alternative to Ribavirin

    Get PDF
    A growing number of arenaviruses are known to cause viral hemorrhagic fever (HF), a severe and life-threatening syndrome characterized by fever, malaise, and increased vascular permeability. Ribavirin, the only licensed antiviral indicated for the treatment of certain arenaviral HFs, has had mixed success and significant toxicity. Since severe arenaviral infections initially do not present with distinguishing symptoms and are difficult to clinically diagnose at early stages, it is of utmost importance to identify antiviral therapies effective at later stages of infection. We have previously reported that T-705, a substituted pyrazine derivative currently under development as an anti-influenza drug, is highly active in hamsters infected with Pichinde virus when the drug is administered orally early during the course of infection. Here we demonstrate that T-705 offers significant protection against this lethal arenaviral infection in hamsters when treatment is begun after the animals are ill and the day before the animals begin to succumb to disease. Importantly, this coincides with the time when peak viral loads are present in most organs and considerable tissue damage is evident. We also show that T-705 is as effective as, and less toxic than, ribavirin, as infected T-705-treated hamsters on average maintain their weight better and recover more rapidly than animals treated with ribavirin. Further, there was no added benefit to combination therapy with T-705 and ribavirin. Finally, pharmacokinetic data indicate that plasma T-705 levels following oral administration are markedly reduced during the latter stages of disease, and may contribute to the reduced efficacy seen when treatment is withheld until day 7 of infection. Our findings support further pre-clinical development of T-705 for the treatment of severe arenaviral infections

    Simulation of high-frequency sinusoidal electrical block of mammalian myelinated axons

    No full text
    High frequency alternating current (HFAC) sinusoidal waveforms can block conduction in mammalian peripheral nerves. A mammalian axon model was used to simulate the response of nerves to HFAC conduction block. Sinusoidal waveforms from 1 to 40 kHz were delivered to eight simulated axon diameters ranging from 7.3 to 16 microm. Conduction block was obtained between 3 to 40 kHz. The minimum peak to peak current at which block was obtained, defined as the block threshold, increased with increasing frequency. Block threshold varied inversely with axon diameter. Upon initiation, the HFAC waveform produced one or more action potentials. These simulation results closely parallel previous experimental results of high frequency motor block of the rat sciatic and cat pudendal nerve. During HFAC block, the axons showed a dynamic steady state depolarization of multiple nodes, strongly suggesting a depolarization mechanism for HFAC conduction block

    Energy efficient neural stimulation: coupling circuit design and membrane biophysics.

    Get PDF
    The delivery of therapeutic levels of electrical current to neural tissue is a well-established treatment for numerous indications such as Parkinson's disease and chronic pain. While the neuromodulation medical device industry has experienced steady clinical growth over the last two decades, much of the core technology underlying implanted pulse generators remain unchanged. In this study we propose some new methods for achieving increased energy-efficiency during neural stimulation. The first method exploits the biophysical features of excitable tissue through the use of a centered-triangular stimulation waveform. Neural activation with this waveform is achieved with a statistically significant reduction in energy compared to traditional rectangular waveforms. The second method demonstrates energy savings that could be achieved by advanced circuitry design. We show that the traditional practice of using a fixed compliance voltage for constant-current stimulation results in substantial energy loss. A portion of this energy can be recuperated by adjusting the compliance voltage to real-time requirements. Lastly, we demonstrate the potential impact of axon fiber diameter on defining the energy-optimal pulse-width for stimulation. When designing implantable pulse generators for energy efficiency, we propose that the future combination of a variable compliance system, a centered-triangular stimulus waveform, and an axon diameter specific stimulation pulse-width has great potential to reduce energy consumption and prolong battery life in neuromodulation devices

    Designing the Optical Interface of a Transcutaneous Optical Telemetry Link

    No full text

    Adjustable compliance stimulator.

    No full text
    <p>(A) Experimental stimulator design. (B–D) Voltage/Current traces during a single trial of stimulation with a 200 µs rectangular waveform at threshold. Stimulation with the minimum calculated compliance voltage (2.8 V). (B) Voltage across the FET. (C) Voltage across the tissue and electrode load. (D) Stimulation current.</p

    Stimulus waveform comparison.

    No full text
    <p>Stimulus amplitude for both the rectangular and triangular waveforms was set to the threshold amplitude for maximal contractile force in the gastrocnemius muscle. (A) The threshold energy dissipated across the combined electrode-tissue load was determined for both waveforms, with pulse-widths ranging from 10 to 500 µs. (B) The mean voltage during stimulation for both waveforms. (C) The peak current during stimulation. (D) Charge injected across the load. (E) Direct comparison of charge injection and energy dissipation. Error bars represent standard error. Significance indicated with * for p<0.05, ** for p<0.01, and *** for p<0.001.</p

    Fixed versus adjustable compliance voltage.

    No full text
    <p>(A) Stimulator energy consumed to maximally activate a rat sciatic nerve. Stimulator set to a compliance voltage of 5 V, 10 V, 20 V and the minimum compliance voltage. Stimulation tested across a range of pulse-widths. Incomplete datasets (compliance voltage was insufficient to activate nerve in some animals) were not included in statistical analyses. (B) For reference only, the stimulator energy consumed to activate rat sciatic nerve, with incomplete datasets included. (C) Energy consumed by the FET and by the load across a range of pulse-widths, with compliance voltage minimized. Error bars represent standard error.</p

    Simulated nerve bundle.

    No full text
    <p>Normalized energy required to recruit 50% of the axons of different diameters in a simulated nerve bundle, across a range of pulse-widths (10–1000 µs; 10 µs resolution).</p
    corecore