23 research outputs found

    Risk and Severity of COVID-19 and ABO Blood Group in Transcatheter Aortic Valve Patients

    No full text
    While cardiovascular disease has been associated with an increased risk of coronavirus disease 2019 (COVID-19), no studies have described its clinical course in patients with aortic stenosis who had undergone transcatheter aortic valve replacement (TAVR). Numerous observational studies have reported an association between the A blood group and an increased susceptibility to SARS-CoV-2 infection. Our objective was to investigate the frequency and clinical course of COVID-19 in a large sample of patients who had undergone TAVR and to determine the associations of the ABO blood group with disease occurrence and outcomes. Patients who had undergone TAVR between 2010 and 2019 were included in this study and followed-up through the recent COVID-19 outbreak. The occurrence and severity (hospitalization and/or death) of COVID-19 and their associations with the ABO blood group served as the main outcome measures. Of the 1125 patients who had undergone TAVR, 403 (36%) died before 1 January 2020, and 20 (1.8%) were lost to follow-up. The study sample therefore consisted of 702 patients. Of them, we identified 22 cases (3.1%) with COVID-19. Fourteen patients (63.6%) were hospitalized or died of disease. Multivariable analysis identified the A blood group (vs. others) as the only independent predictor of COVID-19 in patients who had undergone TAVR (odds ratio (OR) = 6.32; 95% confidence interval (CI) = 2.11−18.92; p = 0.001). The A blood group (vs. others; OR = 8.27; 95% CI = 1.83−37.43, p = 0.006) and a history of cancer (OR = 4.99; 95% CI = 1.64−15.27, p = 0.005) were significantly and independently associated with disease severity (hospitalization and/or death). We conclude that patients who have undergone TAVR frequently have a number of cardiovascular comorbidities that may work to increase the risk of COVID-19. The subgroup with the A blood group was especially prone to developing the disease and showed unfavorable outcomes

    Prognostic Value of Incomplete Revascularization after Percutaneous Coronary Intervention Following Acute Coronary Syndrome: Focus on CKD Patients

    No full text
    International audienceBackground: Residual coronary artery disease (CAD) has been associated with worsened prognosis in patients undergoing percutaneous coronary intervention (PCI) for acute coronary syndromes (ACS). The residual SYNTAX Score (rSS) aims to assess residual CAD after PCI. The association between kidney function and rSS has not been investigated in ACS patients. In this study, we sought to determine whether chronic kidney disease (CKD) patients exhibit more incomplete revascularization following stage revascularization procedures by PCI. We evaluated the impact of incomplete revascularization on the occurrence of major cardiovascular events (MACE) at one-year follow-up. Methods: A total of 831 ACS patients undergoing PCI were divided into 3 subgroups according to their estimated Glomerular Filtration Rate (eGFR): 695 with eGFR ≄ 60 mL/min/1.73 m 2 , 108 with eGFR 60-30 mL/min/1.73 m 2 , 28 with eGFR 8. The primary endpoint was the occurrence of MACE (all-cause mortality, myocardial infarction (MI), repeated revascularization except from planned revascularization, stroke and definite or probable recurrent stent thrombosis) one year after the index procedure. Results: Severe CKD patients had significantly higher MACE (12.0% vs. 25.9% vs. 35.7%; p 8 had higher MACE, all-cause and cardiovascular mortality. CKD was an independent predictive factor of rSS > 8 (HR: 1.65, 95% CI: 1.01 to 2.71; p = 0.048). Multivariate analysis identified rSS > 8, but not CKD, as an independent predictor of cardiac death and MACE. Conclusion: In ACS, CKD is predictive of incomplete revascularization, which stands out as a strong predictor of adverse cardiovascular outcomes including cardiac death and MACE

    Impact of Opioid Analgesia and Inhalation Sedation Kalinox on Pain and Radial Artery Spasm during Transradial Coronary Angiography

    No full text
    With respect to the transfemoral approach, transradial procedures enable a drastic reduction of bleeding events and are associated with a reduction of mortality. Radial artery spasm (RAS) is one of the most common complications and may lead to patient discomfort and procedural failure. Currently, there is no consensus on the optimal sedation protocol to avoid RAS. The aim of this study was to investigate the respective impact of opioids analgesia and inhalation sedation with a 50% nitrous oxide/oxygen premix (Kalinox) on pain and occurrence of RAS during transradial coronary procedures. Consecutive patients undergoing transradial coronary angiography were prospectively enrolled in one, single center observational study (Nouvel Hôpital Civil, Strasbourg, France). Patients received opioids analgesia or inhalation sedation with Kalinox. The primary endpoints of the study were the incidence of a pain scale ≥5/10 and the occurrence of RAS. The secondary endpoints were the incidence of side effects. A total of 325 patients were enrolled (185 in the opioids analgesia group, 140 in the Kalinox group). RAS and pain scale ≥5 rates were not significantly different in the opioids analgesia and Kalinox groups (respectively 13.5% vs. 10.0% and 16.2% vs. 11.4%). Headache was more frequently observed in the Kalinox group (6.4% vs. 0.0%; p = 0.002). By multivariate analysis, female gender, BMI <25 kg/m2, puncture difficulty, the use of plastic needle and 6F sheath were identified as independent predictors of RAS. Procedural inhalation sedation by Kalinox is as safe as opioids analgesia during transradial coronary angiography

    Impact of Antithrombotic Regimen and Platelet Inhibition Extent on Leaflet Thrombosis Detected by Cardiac MDCT after Transcatheter Aortic Valve Replacement

    No full text
    The impact of antithrombotic regimen and platelet inhibition extent on subclinical leaflet thrombosis (SLT) detected by cardiac multidetector computed tomography (MDCT) after transcatheter aortic valve replacement (TAVR) is not well established. Hypoattenuation affecting motion (HAM) has been proposed as a surrogate marker of SLT, and is characterized by hypoattenuated leaflet thickening (HALT) and concomitant reduction in leaflet motion (RELM). We sought to investigate (i) the prevalence of HAM and HALT after TAVR detected by MDCT, (ii) the predictors of SLT, (iii) the impact of oral anticoagulant (OAC) and platelet inhibition extent assessed by platelet reactivity index vasodilator stimulated phosphoprotein (PRI-VASP) and closure time adenosine diphosphate (CT-ADP) on SLT. Of 187 consecutive patients who underwent TAVR from 1 August 2017 to 31 March 2018, 90 of them had cardiac CT at relevant follow-up. Clinical, biological, echocardiographic, procedural characteristics and treatments were collected before, at discharge, and 1 year after TAVR. P2Y12 platelet inhibition extent and primary haemostasis disorders were investigated using platelet PRI-VASP and CT-ADP point-of-care assays. Eighty-five post-TAVR CTs out of 90 were ranked for clarity and assessed with sufficient diagnostic quality. HAM was evidenced in 13 patients (15.3%) and HALT in 30 patients (35%). Procedural characteristics, including aortic valve calcium score, annulus size, or procedural heparin regimens, were equivalent between groups. Likewise, no impact of P2Y12 inhibition (PRI-VASP) nor primary haemostasis disorders (CT-ADP) on SLT could be evidenced. No impact of SLT on valve deterioration evaluated by transthoracic echocardiography (TTE) and clinical events could be established at 12 months follow-up. By multivariate analysis, lack of oral anticoagulant therapy at discharge (HR 12.130 CI 95% (1.394–150.582); p = 0.028) and higher haemoglobin levels were evidenced as the sole independent predictors of SLT. In four patients with HAM, MDCT follow-up was obtained after initiation of OAC therapy and showed a complete regression of HAM. SLT was evidenced in a sizeable proportion of patients treated by TAVR and was mainly determined by the lack of oral anticoagulant therapy. Conversely, no impact of platelet inhibition extent on SLT could be evidenced

    Electrocardiographic Strain Pattern Is a Major Determinant of Rehospitalization for Heart Failure After Transcatheter Aortic Valve Replacement

    No full text
    International audienceBackground Electrocardiographic strain pattern (ESP) has recently been associated with increased adverse outcome in aortic stenosis and after surgical aortic valve replacement. Our study sought to determine the impact and incremental value of ESP pattern in predicting adverse outcome after transcatheter aortic valve replacement.Methods and Results A total of 585 patients with severe aortic stenosis (mean age, 83±7 years; men, 39.8%) were enrolled for transcatheter aortic valve replacement from November 2012 to May 2018. ESP was defined as ≄1‐mm concave down‐sloping ST‐segment depression and asymmetrical T‐wave inversion in the lateral leads. The primary end points of the study were all‐cause mortality, rehospitalization for heart failure, myocardial infarction, and stroke. A total of 178 (30.4%) patients were excluded because of left bundle‐branch block (n=103) or right bundle‐branch block (n=75). Among the 407 remaining patients, 106 had ESP (26.04%). At a median follow‐up of 20.00 months (11.70–29.42 months), no impact of electric strain on overall and cardiac death could be established. By contrast, incidence of rehospitalization for heart failure was significantly higher (33/106 [31.1%] versus 33/301 [11%]; P <0.001) in patients with ESP. By multivariate analyses, ESP remained a strong predictor of rehospitalization for heart failure (hazard ratio, 2.75 [95% CI, 1.61–4.67]; P <0.001).Conclusions In patients with aortic stenosis who were eligible for transcatheter aortic valve replacement, ESP is frequent and associated with an increased risk of postinterventional heart failure regardless of preoperative left ventricular hypertrophy. ESP represents an easy, objective, reliable, and low‐cost tool to identify patients who may benefit from intensified postinterventional follow‐up

    Impact of Incomplete Coronary Revascularization on Late Ischemic and Bleeding Events after Transcatheter Aortic Valve Replacement

    No full text
    BACKGROUND: The impact of coronary artery disease (CAD) and revascularization by percutaneous coronary intervention (PCI) on prognosis in patients undergoing transcatheter aortic valve replacement (TAVR) remain debated. A dismal prognosis in patients undergoing PCI has been associated with elevated baseline SYNTAX score (bSS) and residual SYNTAX score (rSS). The objective was to investigate whether the degree of bSS and rSS impacted ischemic and bleeding events after TAVR. METHODS: bSS and rSS were calculated in 311 patients admitted for TAVR. The primary outcome was the occurrence of major adverse cardiac events (MACE), a composite endpoint of myocardial infarction, stroke, cardiovascular death, or rehospitalization for heart failure. The occurrence of late major/life-threatening bleeding complications (MLBCs) and each primary endpoint individually were the secondary endpoints. RESULTS: bSS > 22 was associated with higher occurrence of MACE (p = 0.013). rSS > 8 and bSS > 22 had no impact on overall cardiovascular mortality. rSS > 8 and bSS > 22 were associated with higher rates of myocardial infarction (p = 0.001 and p = 0.004) and late occurrence of MLBCs. Multivariate analysis showed that bSS > 22 (sHR 2.48) and rSS > 8 (sHR 2.35) remained predictors of MLBCs but not of myocardial infarction. CONCLUSIONS: Incomplete coronary revascularization and CAD burden did not impact overall and cardiac mortality but constitute predictors of late MLBCs in TAVR patients

    Acute kidney injury and acute kidney recovery following Transcatheter Aortic Valve Replacement

    No full text
    International audienceBackground Acute kidney injury (AKI) is associated with a dismal prognosis in Transcatheter Aortic Valve replacement (TAVR). Acute kidney recovery (AKR), a phenomenon reverse to AKI has recently been associated with better outcomes.Methods: Between November 2012 to May 2018, we explored consecutive patients referred to our Heart Valve Center for TAVR. AKI was defined according to the VARC-2 definition. Mirroring the VARC-2 definition of AKI, AKR was defined as a decrease in serum creatinine (≄50%) or ≄25% improvement in GFR up to 72 hours after TAVR.Results AKI and AKR were respectively observed in 8.3 and 15.7% of the 574 patients included. AKI and AKR patients were associated to more advanced kidney disease at baseline. At a median follow-up of 608 days (range 355-893), AKI and AKR patients experienced an increased cardiovascular mortality compared to unchanged renal function patients (14.6% and 17.8% respectively, vs. 8.1%, CI 95%, p<0.022). Chronic kidney disease, (HR: 3.9; 95% CI 1.7-9.2; p < 0.001) was the strongest independent factor associated with AKI similarly to baseline creatinine level (HR: 1; 95% CI 1 to 1.1 p < 0.001) for AKR. 72-hours post procedural AKR (HR: 2.26; 95% CI 1.14 to 4.88; p = 0.021) was the strongest independent predictor of CV mortality.Conclusions: Both AKR and AKI negatively impact long term clinical outcomes of patients undergoing TAVR

    Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study

    No full text
    Published data on the size-specific effective orifice area (EOA) of transcatheter heart valves (THVs) remain scarce. Here, we sought to investigate the intra-individual changes in EOA and mean transvalvular aortic gradient (MG) of the Sapien 3 (S3), CoreValve (CV), and Evolut R (EVR) prostheses both at short-term and at 1-year follow-up. The study sample consisted of 260 consecutive patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI). EOAs and MGs were measured with Doppler echocardiography for the following prostheses: S3 23 mm (n = 74; 28.5%), S3 26 mm (n = 67; 25.8%), S3 29 mm (n = 20; 7.7%), CV 23 mm (n = 2; 0.8%), CV 26 mm (n = 15; 5.8%), CV 29 mm (n = 24; 9.2%), CV 31 mm (n = 9; 3.5%), EVR 26 mm (n = 22; 8.5%), and EVR 29 mm (n = 27; 10.4%). Values were obtained at discharge, 1 month, 6 months, and 1 year from implantation. At discharge, EOAs were larger and MGs lower for larger-size prostheses, regardless of being balloon-expandable or self-expandable. In patients with small aortic annulus size, the hemodynamic performances of CV and EVR prostheses were superior to those of S3. However, we did not observe significant differences in terms of all-cause mortality according to THV type or size. Both balloon-expandable and self-expandable new-generation THVs show excellent hemodynamic performances without evidence of very early valve degeneration
    corecore