92 research outputs found

    In-vitro evaluation of photofunctionalized implant surfaces in a high-glucose microenvironment simulating diabetics

    Get PDF
    The present study aimed to assess the efficacy of photofunctionalization on commercially available dental implant surfaces in a high-glucose environment. Discs of three commercially available implant surfaces were selected with various nano- and microstructural alterations (Group 1—laser-etched implant surface, Group 2—titanium–zirconium alloy surface, Group 3—air-abraded, large grit, acid-etched surface). They were subjected to photo-functionalization through UV irradiation for 60 and 90 min. X-ray photoelectron spectroscopy (XPS) was used to analyze the implant surface chemical composition before and after photo-functionalization. The growth and bioactivity of MG63 osteoblasts in the presence of photofunctionalized discs was assessed in cell culture medium containing elevated glucose concentration. The normal osteoblast morphology and spreading behavior were assessed under fluorescence and phase-contrast microscope. MTT (3-(4,5 Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) and alizarin red assay were performed to assess the osteoblastic cell viability and mineralization efficiency. Following photofunctionalization, all three implant groups exhibited a reduced carbon content, conversion of Ti4+ to Ti3+, increased osteoblastic adhesion, viability, and increased mineralization. The best osteoblastic adhesion in the medium with increased glucose was seen in Group 3. Photofunctionalization altered the implant surface chemistry by reducing the surface carbon content, probably rendering the surfaces more hydrophilic and conducive for osteoblastic adherence and subsequent mineralization in high-glucose environment.International Team for Implantolog

    A Comparative Study on Simulated Chairside Grinding and Polishing of Monolithic Zirconia.

    Get PDF
    This study evaluated the effects of different simulated chairside grinding and polishing protocols on the physical and mechanical properties of surface roughness, hardness, and flexural strength of monolithic zirconia. Sintered monolithic zirconia specimens (15 mm × 3 mm × 3 mm) were abraded using three different burs: diamond bur, modified diamond bur (zirconia specified), and tungsten carbide bur, along with a group of unprepared specimens that served as a control group. The study was divided into two phases, Phase 1 and Phase 2. Surface roughness, surface hardness, and flexural strength were assessed before and after the grinding procedure to determine the 'best test group' in Phase 1. The best abrasive agent was selected for Phase 2 of the study. The specimens in Phase 2 underwent grinding with the best abrasive agent selected. Following the grinding, the specimens were then polished using commercially available diamond polishing paste, a porcelain polishing kit, and an indigenously developed low-temperature sintered zirconia slurry. The physical and mechanical properties were again assessed. Results were analyzed using one-way ANOVA test. Specimens were observed under scanning electron microscopy (SEM) and X-ray diffraction (XRD) for their microstructure and crystalline phases, respectively. Grinding with diamond burs did not weaken zirconia (p > 0.05) but produced rougher surfaces than the control group (p < 0.05). Tungsten carbide burs did not significantly roughen the zirconia surface. However, specimens ground by tungsten carbide burs had a significantly reduced mean flexural strength (p < 0.05) and SEM revealed fine surface cracks. Phase transformation was not detected by XRD. Polishing with commercially available polishing agents, however, restored the surface roughness levels to the control group. Dental monolithic zirconia ground with tungsten carbide burs had a significantly reduced flexural strength and a smooth but defective surface. However, grinding with diamond burs roughened the zirconia surface. These defects may be reduced by polishing with commercially available polishing agents. The use of tungsten carbide burs for grinding dental zirconia should not be advocated. Grinding with diamond abrasives does not weaken zirconia but requires further polishing with commercially available polishing agents

    Significance of Effect of Metformin on Cancer Stem Cells – “Need of an Hour” in oral cancer

    Get PDF
    Oral cancer is a life-threatening disease. Advanced therapeutic approaches are still insufficient to improve the prognosis. Effect of Metformin on cancer stem cells (CSCs) provides promising future. Research on diverse molecular mechanisms involved in different kinds of cancers showed a definite correlation. The role in oral squamous cell carcinoma(OSCC) is not yet defines. So, it will be fruitful in future if the research on metformin and CSCs would be done in oral cancer. It would be helpful in improving the results of current antitumor treatment in oral cancer

    Reply to the letter regarding “Chronic mechanical irritation and oral squamous cell carcinoma: A systematic review and meta-analysis”

    Get PDF
    Dear Editor, We thank Dr. Jian Xie for the valuable inputs on our paper titled ‘Chronic mechanical irritation and oral squamous cell carcinoma: A systematic review and meta-analysis [1].’ The first concern of Dr. Xie was that we had included two studies that were based on the same population. We re-examined these papers, one was published in 2010 [2] and the other in 2017 [3] by the same group of authors. Given the significant time difference between the two papers, we did not want to presume they were from the same sample population. There is no clear evidence that they are from the same sample population. Read more in PDF

    Chronic mechanical irritation and oral squamous cell carcinoma: A systematic review and meta-analysis

    Get PDF
    The objective of the present article was to qualitatively and quantitatively review the association between chronic mechanical irritation and oral squamous cell carcinoma (OSCC). PubMed, SCOPUS, and Web of Science databases were searched using the keyword combinations “chronic trauma and oral squamous cell carcinoma; chronic irritation and oral squamous cell carcinoma; chronic irritation and oral cancer; and chronic trauma and oral cancer.” Duplicates and irrelevant articles were excluded after the title and abstract screening. The full texts of the remaining articles were assessed using selection criteria. A total of 375 (PubMed-126; SCOPUS-152; WOS-97) articles were screened, and 343 duplicates and irrelevant articles were excluded from the study. Only 9 of the remaining 32 articles met the selection criteria and were included in the qualitative analysis. Buccal mucosa and tongue, being highly prone to chronic irritation through the dental prosthesis, were the common sites for OSCC. Edentulous subjects with ill-fitting dentures were at a high risk of developing chronic irritation associated-OSCC. According to the Joanna Briggs Institute of risk assessment, eight of the nine included studies had a low risk of bias. The quantitative analysis showed a significant association (p < 0.00001) between the chronic oral mucosal irritation and OSCC with an overall risk ratio of 2.56 at a confidence interval of 1.96-3.35. Chronic oral mucosa irritation has a significant association with OSCC, and the nature of association could be that of a potential co-factor (dependent risk factor) rather than an independent risk factor

    Efficacy of lateral bone augmentation prior to implant placement: A systematic review and meta-analysis

    Full text link
    AIM The aim of the current systematic review was to critically appraise evidence from randomized and prospective non-randomized comparative clinical trials about the efficacy of lateral bone augmentation prior to implant placement and their outcome regarding bone-width gain. MATERIAL AND METHODS Eight databases were searched until May 2018 for randomized and prospective non-randomized comparative trials on lateral bone augmentation prior to implant placement. After elimination of duplicate studies, data extraction and risk-of-bias assessment according to the Cochrane guidelines, random-effects meta-analyses of Mean Differences (MD) or Relative Risks (RR) and their 95% CIs were performed, followed by subgroup, meta-regression, and sensitivity analyses. RESULTS A total of 25 trials (16 randomized / 9 non-randomized) were identified, which included a total of 553 patients (42.2% male; mean age of 43.9 years). In these included studies and populations, various modalities for primary lateral bone augmentation rendered implant placement feasible. Bone width gain was significantly inversely associated with baseline bone width (pooled effect: -0.35 mm/mm; 95% CI: -0.63 to -0.07 mm; p=0.01). % graft resorption demonstrated a correlation with patient age (36% /year, 95% CI: -0.62 to -0.11 mm; p=0.01). The presence of xenograft added to autogenous graft led to less resorption compared to autograft alone (MD: 1.06 mm; 95% CI: 0.21 to 1.92 mm; p=0.01). Barrier membrane did not yield significant difference in terms of bone width gain (MD: -0.33 mm; 95% CI: -2.24 to 1.58 mm; p>0.05) and graft resorption (MD: 0.84 mm; 95% CI: -1.42 to 3.09 mm; p>0.05). CONCLUSIONS Initially smaller bone dimension favors larger bone width gain, which indicates that a severe lateral bone deficiency can be effectively augmented applying primary lateral bone augmentation. Patients' age and recipient site (maxilla or mandible) seems to influence graft resorption. The addition of a xenograft can be helpful for reducing graft resorption. This article is protected by copyright. All rights reserved

    Ultrasound and CBCT analysis of blood flow and dimensions of the lingual vascular canal: A case control study

    Get PDF
    Objective To assess the correlation between the diameter of the mandibular lingual vascular canal (MLVC) as determined on CBCT examination to blood flow and arterial diameter as determined by ultrasound Doppler analysis (USG) in dentate and edentulous patients. Methods 20 subjects were equally distributed into two groups based on the status of their dentition. Group 1 included dentate subjects (DE) and Group 2 included edentulous subjects (ED).The subjects from both the groups underwent CBCT scan for the assesement of the diameter of the MLVC.Similarly, USG was done to assess the diameter of the sublingual artery anastomosis and blood flow in the anterior mandible. Data was analysed using Karl Pearson’s Correlation coefficient test and Student’s unpaired ‘t’ test. Results Irrespective of the status of the dentition and age, a positive correlation was noted between the diameter of foramen on CBCT examination and the diameter of anastomosing artery as studied by the USG (r ​= ​0.290).Similarly, a positive correlation was observed between the diameter of foramen on CBCT and the volume of blood entering the mandible (r ​= ​0.447).A positive correlation (r ​= ​0.138) was observed between the diameter of the anastomosing artery and the volume of blood entering the mandible. Conclusion The anterior mandible has a rich vascular supply independent of age and status of the dentition.The dimensions and location of MVLC could be assessed on a CBCT prior to implant placement so that the operating surgeon has an idea about the vascularity of the region. Further studies with higher sample size should be undertaken to confirm these findings

    Evaluation of mechanical and adhesion properties of glass ionomer cement incorporating nano-sized hydroxyapatite particles

    Full text link
    Glass ionomer cement is a widely used luting agent for indirect restorations but presents inferior mechanical properties compared to resin cement due to its low elastic modulus. This study evaluated the mechanical and adhesion properties of glass ionomer luting cements reinforced with nano-sized hydroxyapatite particles (HA). The nano-sized HA particles were synthesized using the co-precipitation technique and the resulting precipitate was characterized using X-ray diffraction analysis (XRD), field emission scanning electron (FESEM) and transmission electron microscopy (TEM). HA particles were incorporated into the glass powder (FUJI I, GC) and the luting agent was manipulated in a liquid to powder ratio of 3:1 into 6% by weight after determining the best ratio. The flexural strength of the luting agent and shear bond strength of dentin were analyzed and compared to other luting agents namely, (a) glass ionomer (FUJI I), (b) resin-modified glass ionomer (RelyX Luting Plus) and (c) adhesive resin cement (RelyX U200). Failure types after debonding from dentin were evaluated under SEM. Flexural strength and bond strength data were analyzed using one-way ANOVA and Tukey's tests (alpha = 0.001). Addition of 6 w % HA particles in the range of 80-150 nm enhanced the flexural strength (30.97 ± 5.9 versus 11.65 ± 5.63) and shear bond strength (0.97 ± 0.41 versus 0.39 ± 0.16) of a conventional glass ionomer luting agent significantly compared to the non-reinforced ones when manipulated at a liquid to powder ratio of 3:1 (P < 0.001). While conventional glass ionomer, HA-reinforced glass ionomer and resin-modified glass ionomer specimens showed exclusively mixed type of failures, adhesive resin cement showed cohesive failures within the resin cement. Increased mechanical and adhesion potential of the experimental glass ionomer luting agent after incorporation of HA particles could expand the scope of application of this cement

    Effect of simulated chairside grinding procedures using commercially available abrasive agents on the surface properties of zirconia

    No full text
    Aim: The aim of the present study was to assess the change in physical properties (surface roughness, surface hardness and phase transformation) after surface grinding of zirconia by using three commercially available abrasives. Materials and Methods: Thirty sintered zirconia specimens were prepared and divided into three groups namely Group M (grinded using Mani Dia diamond bur standard grit), Group T (grinded using Tri Hawk diamond bur coarse grit) and Group P (grinded using Predator carbide bur). A customised assembly was used to follow a standardised protocol for surface grinding. The surface roughness, surface hardness and phase transformation was recorded before and after the grinding procedure. Statistical Analysis Used: ANOVA and Bonferroni post hoc test were used to assess the values obtained after the testing the surface roughness and surface hardness. Results: The results of the present study revealed the average values of change in surface roughness as Group M (0.44 μm) and Group T (1.235 μm) and Group P (-0.88 μm). The average values of change in surface hardness were Group T (19.578 HV), Group M (46.722 HV) and Group P (36.429 HV). The change in surface hardness was not statistically significant. There was no phase transformation seen after the grinding procedure. Clinical Significance: Carbide burs along with copious water irrigation when used to grind zirconia intra-orally produces has a polishing effect, minimal change in hardness & no phase transformation. The present study advocates the use of carbides for chair-side grinding of zirconia
    corecore