32 research outputs found

    Cost of AF Ablation: Where Do We Stand?

    Get PDF
    Atrial fibrillation (AF) is a common and frequently disabling chronic condition associated with significant patient morbidity and affecting an increasing stratum of our ageing society. Direct costs related to atrial fibrillation are comprised from direct cost of medical therapy, catheter ablation, and related hospitalizations and imaging procedures, with indirect costs related to complications of the primary therapeutic strategy, management of related conditions, as well as disability and loss in quality of life related to AF. Over the last decade, catheter ablation became a promising alternative to rate and rhythm control among symptomatic AF patients. The purpose of this paper is to describe the evidence on the financial implications related to ablation based on published data and authors' experience

    Fluoroless catheter ablation of atrial fibrillation: integration of intracardiac echocardiography and cartosound module

    Get PDF
    Objective: To evaluate the feasibility, safety, and clinical efficacy of non-fluoroscopic radiofrequency catheter ablation of atrial fibrillation (AF) in comparison to traditional fluoroscopy-guided ablation in a local Canadian community cohort. Methods: We retrospectively studied consecutive patients with paroxysmal and persistent AF undergoing pulmonary vein isolation (PVI) guided by intracardiac echocardiography (ICE) and Carto system (CartoSound module). ICE-guided PVI without fluoroscopy (Zero-fluoro group) was performed in 116 patients, and conventional fluoroscopy-guided PVI (Traditional group) was performed in 131 patients. Results: Two hundred and forty-seven patients with AF (60.7% male; mean age: 62.2 ± 10.6 years; paroxysmal AF =63.1%) who underwent PVI were studied. Mean procedure times were similar between both groups (136.8±33.4 minutes in the zero-fluoro group vs. 144.3±44.9 minutes in the traditional group; p=0.2). Acute PVI was achieved in all patients. Survival from early AF recurrence was 85% and 81% in the zero-fluoro and traditional groups, respectively (p = 0.06). Survival from late AF recurrence (12-months) between the zero-fluoro and traditional groups was also similar (p=0.1). Moreover, there were no significant differences between complication rates, including hematoma (p = 0.2) and tamponade (p = 1),between both groups. Conclusions: Zero-fluoroscopy ICE and CartoSound-guided AF ablation may be safe and feasible in patients undergoing PVI compared to conventional fluoroscopy-guided ablation

    Current Issues in Atrial Fibrillation

    No full text
    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. It places an enormous burden on the patients, caregivers, and the society at large. While the main themes in the care of an AF patient have not changed over the years and continue to focus on stroke prevention, control of the ventricular, rate and rhythm maintenance, there have been a number of new developments in each of these realms. This paper will discuss the “hot” topics in AF in 2012 including new and upcoming medical and invasive management strategies for this condition.Peer Reviewe

    Cost of Atrial Fibrillation: Invasive vs Non-Invasive Management in 2012

    No full text

    Pseudoaneurysm of thoracic aorta presenting as inappropriate sinus tachycardia and chronic cough

    No full text
    Background Pseudoaneurysm of thoracic aorta as a complication of blunt trauma to the chest, can present with a variety of symptoms due to mass compression effect. Here we report the first pseudoaneurysm of thoracic aorta presenting with chronic cough and inappropriate sinus tachycardia. The purpose of this case report is to highlight pseudoaneurysm of thoracic aorta as a rare differential diagnosis for inappropriate sinus tachycardia. Case presentation Here we report a case of 29-year-old white woman, a nurse, with history of a motor vehicle accident. She initially presented to medical attention with inappropriate sinus tachycardia 2 years following the motor vehicle accident during her pregnancy. Six years later she underwent sinoatrial node modification after failing a number of medications. Days prior to the ablation she developed a mild cough which became constant within a week following ablation. A computed tomography scan of her chest performed as part of a workup revealed an outpouching of the inferomedial aspect of the aortic arch, which was compressing her left main bronchus. She underwent arch repair surgery and recovered without complications. Four years later she presented with significant symptomatic sinus bradycardia requiring pacemaker placement. Conclusions This is the first reported case of thoracic pseudoaneurysm of aorta presenting with inappropriate sinus tachycardia due to compression of the vagal nerve and cough as a result of the left main bronchus compressive effect; it highlights the importance of considering structural abnormalities in a differential diagnosis of inappropriate sinus tachycardia before any interventions.York University Librarie
    corecore