47 research outputs found

    Rapid Assessment of Power Requirements and Optimization of Thermal Ice Protection Systems

    Get PDF
    Presented at 2018 Aviation Technology, Integration, and Operations Conference (AIAA 2018-4136)A thermal ice protection system prevents or dispatches ice formed on critical aircraft components like wings or nacelles by heating them either through electro-thermal or pneumatic means. The power requirements for such a system are a function of flight and atmospheric conditions and protected surface area. The developed analysis framework allows evaluation of transient and steady-state cases, anti-icing and de-icing designs, as well as evaporative and running-wet operation. To enable these analyses, a flow solver is first used to calculate local water catch efficiencies and convective heat transfer coefficients on an airfoil. These are then used within a thermal solver which evaluates water and ice accumulations over multiple control volumes under different cases of interest. This control volume approach includes both thermal and mass balances to track temperatures of the protected surface, ice, and water, as well as water/ice layer thicknesses and the water mass flow in or out of the control volume through evaporation or runback. Finally, this tool can yield power requirements for different system layouts and operating conditions, or optimize the protected surface area for a given airfoil under given operating conditions. This can help designers get an estimate of the power draw, and obtain more information on placement of the IPS on novel configurations during the design space exploration phase itself with greater fidelity and minimal computational costs

    Rheological constitutive equation for model of soft glassy materials

    Full text link
    We solve exactly and describe in detail a simplified scalar model for the low frequency shear rheology of foams, emulsions, slurries, etc. [P. Sollich, F. Lequeux, P. Hebraud, M.E. Cates, Phys. Rev. Lett. 78, 2020 (1997)]. The model attributes similarities in the rheology of such ``soft glassy materials'' to the shared features of structural disorder and metastability. By focusing on the dynamics of mesoscopic elements, it retains a generic character. Interactions are represented by a mean-field noise temperature x, with a glass transition occurring at x=1 (in appropriate units). The exact solution of the model takes the form of a constitutive equation relating stress to strain history, from which all rheological properties can be derived. For the linear response, we find that both the storage modulus G' and the loss modulus G'' vary with frequency as \omega^{x-1} for 1<x<2, becoming flat near the glass transition. In the glass phase, aging of the moduli is predicted. The steady shear flow curves show power law fluid behavior for x<2, with a nonzero yield stress in the glass phase; the Cox-Merz rule does not hold in this non-Newtonian regime. Single and double step strains further probe the nonlinear behavior of the model, which is not well represented by the BKZ relation. Finally, we consider measurements of G' and G'' at finite strain amplitude \gamma. Near the glass transition, G'' exhibits a maximum as \gamma is increased in a strain sweep. Its value can be strongly overestimated due to nonlinear effects, which can be present even when the stress response is very nearly harmonic. The largest strain \gamma_c at which measurements still probe the linear response is predicted to be roughly frequency-independent.Comment: 24 pages, REVTeX, uses multicol, epsf and amssymp; 20 postscript figures (included). Minor changes to text (relation to mode coupling theory, update on recent foam simulations etc.) and figures (emphasis on low frequency regime); typos corrected and reference added. Version to appear in Physical Review

    Does varicocele repair improve conventional semen parameters? A meta-analytic study of before-after data

    Get PDF
    Purpose The purpose of this meta-analysis is to study the impact of varicocele repair in the largest cohort of infertile males with clinical varicocele by including all available studies, with no language restrictions, comparing intra-person conventional semen parameters before and after the repair of varicoceles. Materials and Methods The meta-analysis was performed according to PRISMA-P and MOOSE guidelines. A systematic search was performed in Scopus, PubMed, Cochrane, and Embase databases. Eligible studies were selected according to the PICOS model (Population: infertile male patients with clinical varicocele; Intervention: varicocele repair; Comparison: intra-person before-after varicocele repair; Outcome: conventional semen parameters; Study type: randomized controlled trials [RCTs], observational and case-control studies). Results Out of 1,632 screened abstracts, 351 articles (23 RCTs, 292 observational, and 36 case-control studies) were included in the quantitative analysis. The before-and-after analysis showed significant improvements in all semen parameters after varicocele repair (except sperm vitality); semen volume: standardized mean difference (SMD) 0.203, 95% CI: 0.129–0.278; p<0.001; I2=83.62%, Egger’s p=0.3329; sperm concentration: SMD 1.590, 95% CI: 1.474–1.706; p<0.001; I2=97.86%, Egger’s p<0.0001; total sperm count: SMD 1.824, 95% CI: 1.526–2.121; p<0.001; I2=97.88%, Egger’s p=0.0063; total motile sperm count: SMD 1.643, 95% CI: 1.318–1.968; p<0.001; I2=98.65%, Egger’s p=0.0003; progressive sperm motility: SMD 1.845, 95% CI: 1.537%–2.153%; p<0.001; I2=98.97%, Egger’s p<0.0001; total sperm motility: SMD 1.613, 95% CI 1.467%–1.759%; p<0.001; l2=97.98%, Egger’s p<0.001; sperm morphology: SMD 1.066, 95% CI 0.992%–1.211%; p<0.001; I2=97.87%, Egger’s p=0.1864. Conclusions The current meta-analysis is the largest to date using paired analysis on varicocele patients. In the current meta-analysis, almost all conventional semen parameters improved significantly following varicocele repair in infertile patients with clinical varicocele. Keywords Controlled before-after studies; Infertility, male; Meta-analysis; Varicocel

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Corporate Governance and Financial Distress: evidence from Taiwan

    No full text
    Prior empirical evidence supports the wealth expropriation hypothesis that weak corporate governance induced by certain types of ownership structures and board composition tends to result in minority interest expropriation. This in turn reduces corporate value. However, it is still unclear whether corporate financial distress is related to these corporate governance characteristics. To answer this question, we adopt three variables to proxy for corporate governance risk, namely, the percentage of directors occupied by the controlling shareholder, the percentage the controlling shareholders shareholding pledged for bank loans (pledge ratio), and the deviation in control away from the cash flow rights. Binary logistic regressions are then fitted to generate dichotomous prediction models. Taiwanese listed firms, characterised by a high degree of ownership concentration, similar to that in most countries, are used as our empirical samples. The evidence suggests that the three variables mentioned above are positively related to the risk for financial distress in the following year. Generally speaking, firms with weak corporate governance are vulnerable to economic downturns and the probability of falling into financial distress increases. Copyright Blackwell Publishing Ltd. 2004.
    corecore