    Long-term clinical outcomes of everolimus-eluting bioresorbable scaffolds versus everolimus-eluting stents:final five-year results of the AIDA randomised clinical trial

    Get PDF
    Background: Absorb bioresorbable vascular scaffold (BVS)-related events have been reported between 1 and 3 years – the period of active scaffold bioresorption. Data on the performance of the Absorb BVS in daily clinical practice beyond this time point are scarce. Aims: This report aimed to provide the final five-year clinical follow-up of the Absorb BVS in comparison with the XIENCE everolimus-eluting stent (EES). In addition, we evaluated the effect of prolonged dual antiplatelet therapy (DAPT) administration on events in the scaffold group. Methods: AIDA was a multicentre, investigator-initiated, non-inferiority trial, in which 1,845 unselected patients with coronary artery disease were randomly assigned to either the Absorb BVS (n=924) or the XIENCE EES (n=921). Target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction or target vessel revascularisation, was the primary endpoint. Scaffold thrombosis cases were matched with controls and tested for the effect of prolonged DAPT. Results: Up to five-year follow-up, there was no difference in TVF between the Absorb BVS (17.7%) and the XIENCE EES (16.1%) (hazard ratio [HR] 1.31, 95% confidence interval [CI]: 0.90-1.41; p=0.302). Definite or probable device thrombosis (DT) occurred in 43 patients (4.8%) in the scaffold group compared to 13 patients (1.5%) in the stent group (HR 3.32, 95% CI: 1.78-6.17; p<0.001). DT between 3 and 4 years occurred six times in the Absorb arm versus three times in the XIENCE arm. Between 4 and 5 years, the incidence was three versus two, respectively. Of those three DT in the scaffold group, two occurred in XIENCE EES-treated lesions. The odds ratio of scaffold thrombosis in patients on DAPT compared to off DAPT throughout five-year follow-up was 0.36 (95% CI: 0.15-0.86). Conclusions: The excess risk of the Absorb BVS on late adverse events, in particular device thrombosis, in routine PCI continues up to 4 years and seems to plateau afterwards

    Three-year clinical outcomes of the absorb bioresorbable vascular scaffold compared to Xience everolimus-eluting stent in routine PCI in patients with diabetes mellitus—AIDA sub-study

    Get PDF
    Background: In this prespecified AIDA-trial sub-study we investigate the clinical performance of absorb bioresorbable vascular scaffold (BVS) compared to Xience everolimus-eluting stent (EES) in routine percutaneous coronary intervention (PCI) in patients with diabetes mellitus (DM) at complete 3-year follow-up. Methods and results: All 1,845 randomized patients were subdivided by medical history with DM or without DM. Of the 924 Absorb BVS patients, 171 (18.5%) patients had DM, of which 65 (38.0%) were treated with insulin (iTDM). Of the 921 Xience EES patients, 153 (16.6%) patients had DM, of which 45 (29.4%) were insulin-treated diabetes mellitus (iTDM). Target vessel failure (TVF), composite of cardiac death, target vessel myocardial infarction, and target vessel revascularization, occurred in 18.7% of diabetic patients treated with Absorb patients versus in 18.0% patients treated with Xience EES (p =.840). In nondiabetics the rates of TVF were 12.3% in Absorb BVS versus 11.0% in Xience EES (p =.391). Definite/probable device thrombosis occurred more frequently in Absorb BVS compared to Xience EES in both diabetic and nondiabetic patients (4.8% versus 0.7%; p =.028 and 3.2% vs. 0.5%; p &lt;.001, respectively). Conclusions: In routine PCI practice, both Absorb BVS and Xience EES have worse clinical outcomes in diabetic patients as compared to nondiabetic patients. Throughout all clinical presentations, Absorb BVS was associated with higher rates of device thrombosis at 3-year follow-up.</p
    corecore