Status and Strategy for Moisture Metrology in European Metrology Institutes
Measurement of moisture in materials presents many challenges, due to diverse measuring principles, sample interactions with atmosphere, and variation in what is measured (either water content alone or moisture including other liquids). Calibrations are variously referenced to published standard methods, primary calibration facilities, or certified reference materials, but each of these addresses limited substances and ranges of measurement. Overall, metrology infrastructure is not as fully developed or coherent for this field as it is for many other areas of measurement. In order to understand the metrology needs and to support developments, several European national metrology institutes (NMIs) have undertaken some collaborative activities. These have included a “cooperation in research” project for sharing of information, a survey of moisture capabilities at NMIs, the formulation of a strategy for moisture metrology at the NMI level, and a funded research project to develop improved metrology for the moisture field. This paper summarizes the information gathered, giving an overview of the status of moisture metrology at NMIs, and it reports a proposed strategy to improve the current situation
Investigation of the Equivalence of the National Dew-Point Temperature Realizations in the Range -50 °C TO +20 °C
In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4 years after the starting initial measurements in the project. In total, 24 NMIs from different countries took part in the comparison. This number includes 22 EURAMET countries, and Russia and South Africa. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was carried out in three parallel loops, each with two chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. It is shown that the standard uncertainty due to the long-term instability was smaller than 0.008 °C in all loops. The standard uncertainties due to links between the loops were found to be smaller than 0.025 °C at -50 °C and 0.010 °C elsewhere. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from the EURAMET comparison reference values (ERV). Taking into account 16 different primary dew-point realizations and 8 secondary realizations, the results demonstrate the equivalence of a large number of laboratories at an uncertainty level that is better than achieved in other multilateral comparisons so far in the humidity field