Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency
We have investigated the radiation damage effects on a CCD to be employed in
the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray
Image (MAXI) onboard the International Space Station (ISS). Since low energy
protons release their energy mainly at the charge transfer channel, resulting a
decrease of the charge transfer efficiency, we thus focused on the low energy
protons in our experiments. A 171 keV to 3.91 MeV proton beam was irradiated to
a given device. We measured the degradation of the charge transfer inefficiency
(CTI) as a function of incremental fluence. A 292 keV proton beam degraded the
CTI most seriously. Taking into account the proton energy dependence of the
CTI, we confirmed that the transfer channel has the lowest radiation tolerance.
We have also developed the different device architectures to reduce the
radiation damage in orbit. Among them, the ``notch'' CCD, in which the buried
channel implant concentration is increased, resulting in a deeper potential
well than outside, has three times higher radiation tolerance than that of the
normal CCD. We then estimated the charge transfer inefficiency of the CCD in
the orbit of ISS, considering the proton energy spectrum. The CTI value is
estimated to be 1.1e-5 per each transfer after two years of mission life in the
worse case analysis if the highest radiation-tolerant device is employed. This
value is well within the acceptable limit and we have confirmed the high
radiation-tolerance of CCDs for the MAXI mission.Comment: 17 pages, 2 table, 12 figures. Accepted for publication of Japanese
Journal of Applied Physics. High resolution file is available from
http://wwwxray.ess.sci.osaka-u.ac.jp/~miyata/paper/proton_cti.pd