11 research outputs found

    3-Dimensional Tuning of an Atomically Defined Silicon Tunnel Junction

    Full text link
    A requirement for quantum information processors is the in-situ tunability of the tunnel rates and the exchange interaction energy within the device. The large energy level separation for atom qubits in silicon is well suited for qubit operation but limits device tunability using in-plane gate architectures, requiring vertically separated top-gates to control tunnelling within the device. In this paper we address control of the simplest tunnelling device in Si:P, the tunnel junction. Here we demonstrate that we can tune its conductance by using a vertically separated top-gate aligned with +-5nm precision to the junction. We show that a monolithic 3D epitaxial top-gate increases the capacitive coupling by a factor of 3 compared to in-plane gates, resulting in a tunnel barrier height tunability of 0-186meV. By combining multiple gated junctions in series we extend our monolithic 3D gating technology to implement nanoscale logic circuits including AND and OR gates

    Addressable electron spin resonance using donors and donor molecules in silicos

    Get PDF
    Phosphorus donor impurities in silicon are a promising candidate for solid-state quantum computing due to their exceptionally long coherence times and high fidelities. However, individual addressability of exchange coupled donors with separations ~15 nm is challenging. We show that by using atomic precision lithography, we can place a single P donor next to a 2P molecule 16 ± 1 nm apart and use their distinctive hyperfine coupling strengths to address qubits at vastly different resonance frequencies. In particular, the single donor yields two hyperfine peaks separated by 97 ± 2.5 MHz, in contrast to the donor molecule that exhibits three peaks separated by 262 ± 10 MHz. Atomistic tight-binding simulations confirm the large hyperfine interaction strength in the 2P molecule with an interdonor separation of ~0.7 nm, consistent with lithographic scanning tunneling microscopy images of the 2P site during device fabrication. We discuss the viability of using donor molecules for built-in addressability of electron spin qubits in silicon

    Coherent control of a donor-molecule electron spin qubit in silicon

    Get PDF
    Donor spins in silicon provide a promising material platform for large scale quantum computing. Excellent electron spin coherence times of T2*=268 μs with fidelities of 99.9% have been demonstrated for isolated phosphorus donors in isotopically pure 28Si, where donors are local-area-implanted in a nanoscale MOS device. Despite robust single qubit gates, realising two-qubit exchange gates using this technique is challenging due to the statistical nature of the dopant implant and placement process. In parallel a precision scanning probe lithography route has been developed to place single donors and donor molecules on one atomic plane of silicon with high accuracy aligned to heavily phosphorus doped silicon in-plane gates. Recent results using this technique have demonstrated a fast (0.8 ns) two-qubit gate with two P donor molecules placed 13 nm apart in natSi. In this paper we demonstrate a single qubit gate with coherent oscillations of the electron spin on a P donor molecule in natSi patterned by scanning tunneling microscope (STM) lithography. The electron spin exhibits excellent coherence properties, with a T2 decoherence time of 298 ± 30 μs, and T2* dephasing time of 295 ± 23 ns

    Prediction of outcome in patients with suspected acute ischaemic stroke with CT perfusion and CT angiography: The Dutch acute stroke trial (DUST) study protocol

    Get PDF
    Background: Prediction of clinical outcome in the acute stage of ischaemic stroke can be difficult when based on patient characteristics, clinical findings and on non-contrast CT. CT perfusion and CT angiography may provide additional prognostic information and guide treatment in the early stage. We present the study protocol of the Dutch acute Stroke Trial (DUST). The DUST aims to assess the prognostic value of CT perfusion and CT angiography in predicting stroke outcome, in addition to patient characteristics and non-contrast CT. For this purpose, individualised prediction models for clinical outcome after stroke based on the best predictors from patient characteristics and CT imaging will be developed and validated.Methods/design: The DUST is a prospective multi-centre cohort study in 1500 patients with suspected acute ischaemic stroke. All patients undergo non-contrast CT, CT perfusion and CT angiography within 9 hours after onset of the neurological deficits, and, if possible, follow-up imaging after 3 days. The primary outcome is a dichotomised score on the modified Rankin Scale, assessed at 90 days. A score of 0-2 represents good outcome, and a score of 3-6 represents poor outcome. Three logistic regression models will be developed, including patient characteristics and non-contrast CT (model A), with addition of CT angiography (model B), and CT perfusion parameters (model C). Model derivation will be performed in 60% of the study population, and model validation in the remaining 40% of the patients. Additional prognostic value of the models will be determined with the area under the curve (AUC) from the receiver operating characteristic (ROC) curve, calibration plots, assessment of goodness-of-fit, and likelihood ratio tests.Discussion: This study will provide insight in the added prognosti

    Suppressing Segregation in Highly Phosphorus Doped Silicon Monolayers

    No full text
    Sharply defined dopant profiles and low resistivity are highly desired qualities in the microelectronic industry, and more recently, in the development of an all epitaxial Si:P based quantum computer. In this work, we use thin (monolayers thick) room temperature grown silicon layers, so-called locking layers, to limit dopant segregation in highly phosphorus doped silicon monolayers. We present secondary ion mass spectroscopy and atom probe tomography measurements that demonstrate the effectiveness of locking layers in suppressing P segregation. Scanning tunneling micrographs of the surface of the locking layer show that the growth is epitaxial, despite the low growth temperature, while magnetotransport measurements reveal a 50% decrease in the active carrier density. We show that applying a finely tuned rapid thermal anneal can restore the active carrier density to 3.4 × 10<sup>14</sup> cm<sup>–2</sup> while maintaining ultra sharp dopant profiles. In particular, 75% of the initial deposited P is confined in a layer with a full width at half-maximum thickness of 1.0 nm and a peak P concentration of 1.2 × 10<sup>21</sup> cm<sup>–3</sup> (2.5 atom %)

    Quantitative multiplex profiling of the complement system to diagnose complement-mediated diseases

    No full text
    Objectives Complement deficiencies are difficult to diagnose because of the variability of symptoms and the complexity of the diagnostic process. Here, we applied a novel 'complementomics' approach to study the impact of various complement deficiencies on circulating complement levels. Methods Using a quantitative multiplex mass spectrometry assay, we analysed 44 peptides to profile 34 complement proteins simultaneously in 40 healthy controls and 83 individuals with a diagnosed deficiency or a potential pathogenic variant in 14 different complement proteins. Results Apart from confirming near or total absence of the respective protein in plasma of complement-deficient patients, this mass spectrometry-based profiling method led to the identification of additional deficiencies. In many cases, partial depletion of the pathway up- and/or downstream of the absent protein was measured. This was especially found in patients deficient for complement inhibitors, such as angioedema patients with a C1-inhibitor deficiency. The added value of complementomics was shown in three patients with poorly defined complement deficiencies. Conclusion Our study shows the potential clinical utility of profiling circulating complement proteins as a comprehensive read-out of various complement deficiencies. Particularly, our approach provides insight into the intricate interplay between complement proteins due to functional coupling, which contributes to the better understanding of the various disease phenotypes and improvement of care for patients with complement-mediated diseases

    The Prognostic Value of CT Angiography and CT Perfusion in Acute Ischemic Stroke

    No full text
    Background: CT angiography (CTA) and CT perfusion (CTP) are important diagnostic tools in acute ischemic stroke. We investigated the prognostic value of CTA and CTP for clinical outcome and determined whether they have additional prognostic value over patient characteristics and non-contrast CT (NCCT). Methods: We included 1,374 patients with suspected acute ischemic stroke in the prospective multicenter Dutch acute stroke study. Sixty percent of the cohort was used for deriving the predictors and the remaining 40% for validating them. We calculated the predictive values of CTA and CTP predictors for poor clinical outcome (modified Rankin Scale score 3-6). Associations between CTA and CTP predictors and poor clinical outcome were assessed with odds ratios (OR). Multivariable logistic regression models were developed based on patient characteristics and NCCT predictors, and subsequently CTA and CTP predictors were added. The increase in area under the curve (AUC) value was determined to assess the additional prognostic value of CTA and CTP. Model validation was performed by assessing discrimination and calibration. Results: Poor outcome occurred in 501 patients (36.5%). Each of the evaluated CTA measures strongly predicted outcome in univariable analyses: the positive predictive value (PPV) was 59% for Alberta Stroke Program Early CT Score (ASPECTS) ≤7 on CTA source images (OR 3.3; 95% CI 2.3-4.8), 63% for presence of a proximal intracranial occlusion (OR 5.1; 95% CI 3.7-7.1), 66% for poor leptomeningeal collaterals (OR 4.3; 95% CI 2.8-6.6), and 58% for a >70% carotid or vertebrobasilar stenosis/occlusion (OR 3.2; 95% CI 2.2-4.6). The same applied to the CTP measures, as the PPVs were 65% for ASPECTS ≤7 on cerebral blood volume maps (OR 5.1; 95% CI 3.7-7.2) and 53% for ASPECTS ≤7 on mean transit time maps (OR 3.9; 95% CI 2.9-5.3). The prognostic model based on patient characteristics and NCCT measures was highly predictive for poor clinical outcome (AUC 0.84; 95% CI 0.81-0.86). Adding CTA and CTP predictors to this model did not improve the predictive value (AUC 0.85; 95% CI 0.83-0.88). In the validation cohort, the AUC values were 0.78 (95% CI 0.73-0.82) and 0.79 (95% CI 0.75-0.83), respectively. Calibration of the models was satisfactory. Conclusions: In patients with suspected acute ischemic stroke, admission CTA and CTP parameters are strong predictors of poor outcome and can be used to predict long-term clinical outcome. In multivariable prediction models, however, their additional prognostic value over patient characteristics and NCCT is limited in an unselected stroke population

    Prediction of outcome in patients with suspected acute ischaemic stroke with CT perfusion and CT angiography: The Dutch acute stroke trial (DUST) study protocol

    No full text
    Background: Prediction of clinical outcome in the acute stage of ischaemic stroke can be difficult when based on patient characteristics, clinical findings and on non-contrast CT. CT perfusion and CT angiography may provide additional prognostic information and guide treatment in the early stage. We present the study protocol of the Dutch acute Stroke Trial (DUST). The DUST aims to assess the prognostic value of CT perfusion and CT angiography in predicting stroke outcome, in addition to patient characteristics and non-contrast CT. For this purpose, individualised prediction models for clinical outcome after stroke based on the best predictors from patient characteristics and CT imaging will be developed and validated.Methods/design: The DUST is a prospective multi-centre cohort study in 1500 patients with suspected acute ischaemic stroke. All patients undergo non-contrast CT, CT perfusion and CT angiography within 9 hours after onset of the neurological deficits, and, if possible, follow-up imaging after 3 days. The primary outcome is a dichotomised score on the modified Rankin Scale, assessed at 90 days. A score of 0-2 represents good outcome, and a score of 3-6 represents poor outcome. Three logistic regression models will be developed, including patient characteristics and non-contrast CT (model A), with addition of CT angiography (model B), and CT perfusion parameters (model C). Model derivation will be performed in 60% of the study population, and model validation in the remaining 40% of the patients. Additional prognostic value of the models will be determined with the area under the curve (AUC) from the receiver operating characteristic (ROC) curve, calibration plots, assessment of goodness-of-fit, and likelihood ratio tests.Discussion: This study will provide insight in the added prognostic value of CTP and CTA parameters in outcome prediction of acute stroke patients. The prediction models that will be developed in this study may help guide future treatment decisions in the acute stage of ischaemic stroke
    corecore